9-7-7. - Building Height, Appurtenances.
(a) Appurtenances: Appurtenances may be added under the following circumstances: (1) The addition of an appurtenance to a building is permitted if it does not cause the building height to exceed the height allowed in Sections 9-7-5, "Building Height," and 9-7-6, "Building Height, Conditional," or Chapter 9-14, "Form-Based Code," B.R.C. 1981, as applicable, considering, for this purpose only, the uppermost point of the appurtenance to be the uppermost point of the roof. (2) The city manager may approve additions of appurtenances to buildings causing a building height to exceed the maximum permitted height if the following standards are met: (A) There is a functional need for the appurtenance; (B) The functional need cannot be met with an appurtenance at a lesser height; and (C) Visible materials and colors are compatible with the building to which the appurtenance is attached. (3) No appurtenance may have useable floor area except for mechanical equipment installations or be more than sixteen feet in height. Mechanical equipment, considered cumulatively, may not cover more than twenty-five percent of the roof area of the building. For the purposes of this paragraph, coverage means the total area enclosed by the screening and roof area means the outside top covering of a building which is parallel to the ground. (4) All mechanical equipment is screened from view, regardless of the height of the building, unless in the opinion of the city manager such screening conflicts with the function of the mechanical equipment. The city manager will determine if the screening of the equipment is adequate in form, materials and color based on the following criteria: (A) Screening is consistent with the building design, colors and materials; (B) Appurtenances are placed on the portion of the roof which is least visible from adjacent streets and properties; (C) The height of the screen is the minimum appropriate to adequately screen the mechanical equipment; and (D) Screening does not increase the apparent height of the walls of the building. The use of parapet walls to screen mechanical equipment is discouraged. The height of parapet walls should be the minimum necessary to screen mechanical equipment. (5) A parapet wall may exceed the height requirements of this title by up to eighteen inches if the parapet is necessary to accommodate rooftop drainage or to provide fire protection. (6) An applicant may appeal the decision of the manager under this section to the planning board under the procedures set forth in Section 9-2-7, "Development Review Action," B.R.C. 1981. (b) Landmarked Appurtenances: Notwithstanding any other provision of this section, appurtenances of buildings landmarked under Chapter 9-11, "Historic Preservation," B.R.C. 1981, may be repaired or restored to their previous height, upon approval of the landmarks board. If the board approves such a repair or restoration, the approval is not effective until thirty days after the date of its approval. Promptly after the approval of the repair or restoration, the city manager will forward to the city council a written report, including a description of the repair or restoration and the reasons for the approval. The manager will publish notice of the approval once in a newspaper of general circulation in the City within thirty days after the approval is granted by the board. Upon receiving such report and at any time before the effective date of the approval, the council may rescind the approval and call-up the request for its consideration at a public hearing, which constitutes a revocation of the approval. (c) Rooftop Solar Systems: Rooftop solar systems shall comply with the requirements of this subsection: (1) The rooftop solar system may exceed the roof area coverage requirements in Paragraph (a)(3) if: (A) The system is under fifty-five feet in height; or (B) The system complies with the following limitation for buildings or rooftop solar systems that exceed fifty-five feet in height. The rooftop solar system is: (i) Mounted so that the solar panels are no greater than two feet from a plane parallel to the surface of a roof with a pitch of greater than 2:12. (ii) Mounted so that the solar panels are no greater than ten feet from the surface of a flat roof with a pitch of less than 2:12. (iii) On a parking garage in nonresidential zoning districts, mounted so that the panels are no greater than ten feet from the surface of the highest deck of the parking or parapet wall on the building. (2) The city manager may vary any screening requirement for mechanical equipment if such screening will interfere with the efficient operation of the rooftop solar system. (3) A rooftop solar system is not required to be accessory to the building upon which it is located. (4) If a proposed rooftop solar system is located on a building subject to an approved planned unit development or site review, the application shall meet the standards of this section and the changes to the approved plans shall be reviewed under the standards of Section 9-2-14, "Site Review", B.R.C. 1981, except that a review under the standards of Section 9-2-14, B.R.C. 1981, is not required for flush-mounted rooftop solar systems. For the purposes of this paragraph, flush-mounted means installed directly to the roof in a manner where the solar system is parallel to the roof pitch at no more than eight inches in height above the surface of the roof. Ordinance Nos. 7613 (2008), 7768 (2010), 8357 (2019); 8409 (2020); 8515 (2023); 8669 (2025)
Ask a question about Boulder law
Corpus searches the Boulder sections it holds and shows the ones that match, with their citations. Free, no sign-in.