Sec. 16-85. - Gas connections.
A mechanical contractor shall be limited to the installation of the gas flex line serving the gas appliance. Gas flex lines are limited to a maximum of three (3) feet in length. A listed gas shut-off valve shall be installed on the service side of the furnace within three (3) feet of the furnace gas valve. A solid gas pipe nipple shall be added to the gas valve on the appliance for connection of the flex gas line outside the furnace cabinet, the nipple shall not extend more than four (4) inches outside the cabinet, including any ninety (90) elbow installed. Any addition, replacement, or relocation of the gas pipe must be done by a licensed plumbing contractor with a permit for that particular job.