For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 132-56 — Floors

Code of Ordinances of the City of Stamford, Connecticut (Supp. No. 73, Update 1: codified through Ordinance No. 1333, enacted September 8, 2026) · Stamford Code of Ordinances § 132-56

Corpus is an independent public-information project, not the official City of Stamford website. Stable reference: corpuslaw.us/code/4c65c007-b8b7-4f05-b089-a7af35a32fbf

Sec. 132-56. - Floors.

A. Floor construction. (1) Except as specified in Subsection B of this section, floors and floor coverings of all food preparation, food storage and warewashing areas and the floors of all walk-in refrigerators, dressing rooms, locker rooms, toilet rooms and vestibules shall be constructed of smooth durable material, such as sealed concrete, terrazzo, quarry tile, ceramic tile, durable grades of vinyl asbestos or plastic tile or tight-fitting wood impregnated with plastic, and shall be maintained in good repair. Nothing in this section shall prohibit the use of antislip floor covering in areas where necessary for safety reasons. (2) Floors which are water flushed or which receive discharges of water or other fluid wastes or are in areas where pressure spray methods for cleaning are used shall be provided with properly installed trapped drains. Such floors shall be constructed only of sealed concrete or similar materials and shall be graded to drain. (3) In all establishments utilizing concrete, terrazzo, quarry tile, ceramic tile or similar flooring materials or where water-flush cleaning methods are used, the junctures between walls and floors shall be covered and sealed. In all other cases, the juncture between walls and floors shall be covered so as not to present an open seam of more than one thirty-second ( 1/32 ) inch [eight-tenths (0.8) millimeter]. B. Floor carpeting. Carpeting, if used as a floor covering, shall be of closely woven construction, properly installed, easily cleanable and maintained in good repair. Carpeting shall not be used in food preparation and warewashing areas, in food storage areas or in toilet room areas where urinals or fixtures are located. C. Prohibited floor covering. Sawdust, wood shavings, granular salt, baked clay, diatomaceous earth or similar materials shall not be used as floor coverings; however, these materials may be used in amounts necessary for immediate spot cleanup of spills or drippage on floors. D. Mats and duckboards. Mats and duckboards shall be of nonabsorbent, grease-resistant materials and of such size, design and construction as to facilitate cleaning and shall be maintained in good repair. E. Utility line installation. Exposed utility service lines and pipes shall be installed in a way that does not obstruct or prevent cleaning of the floor. In all new or extensively remodeled establishments, installation of exposed horizontal utility service lines and pipes on the floor is prohibited.

Ask a question about Stamford law

Corpus searches the Stamford sections it holds and shows the ones that match, with their citations. Free, no sign-in.