CHANGES, ADDITIONS OR OMISSIONS TO ASME A17.1.
Madison General Ordinances § 40.035
in effect40.035 - CHANGES, ADDITIONS OR OMISSIONS TO ASME A17.1.
(1) The following language is in addition to the requirements in ASME A17.1: In each elevator an audible signaling device shall be provided. It shall be operable from the emergency stop switch, where required, and from a switch identified as "ALARM", which shall be provided in or adjacent to each car operating panel. The "ALARM" switch of visual identification shall illuminate when the "ALARM" switch is actuated. One audible signaling device shall be permitted to be used for a group of elevators. The audible signaling device shall:
(a) Have a rated sound pressure rating of not less than 80dBA and no more than 90dBA at 3 m (10 feet);
(b) Respond without delay after the switch has been activated;
(c) Be located inside the building and audible inside the car and outside the hoistway; and
(d) For elevators with a travel greater than 30 m (100 ft), be duplicated as follows:
1. One device shall be mounted on the car; and
2. A second device shall be placed at the designated level.
(Sec. 40.035 Cr. by ORD-10-00083, 9-15-10)
Source: City of Madison, Wisconsin, Madison General Ordinances (Municode Library, library.municode.com)URL: https://library.municode.com/wi/madison/codes/code_of_ordinances?nodeId=COORMAWIVOIVCH32--45_CH40COCO_40.035CHADOMASA1Fetched: 11/1/2026