§ 9-194.2 — Design regulations
Code of Ordinances of the City of Pasadena, Texas (Supp. No. 33, Update 2: codified through Ordinance No. 2026-143, enacted September 1, 2026) · Pasadena City Code § 9-194.2
Corpus is an independent public-information project, not the official City of Pasadena website. Stable reference: corpuslaw.us/code/4eecc2ce-773c-42a7-99c9-a744994bb463
Sec. 9-194.2. - Design regulations.
All ponds will meet at a minimum the following regulations regardless if connecting to a drainage facility not maintained by the city: (a) Maintenance berms. Maintenance berms shall be provided at a minimum width of ten (10) feet, and shall be constructed around the entire pond facility. Maintenance berms shall be unencumbered and allow the entrance of vehicles and equipment as necessary to do routine maintenance in accordance with these regulations. Maintenance berms shall not be elevated in relation to adjacent properties. (b) Side slopes. Dry pond facilities shall be established at a ratio of four (4) (horizontal) to one (1) (vertical). Wet pond facilities shall be required to establish four (4) to one (1) side slopes only above the top of finished bulkhead. Vertical wall ponds are not allowed. (c) Bottom slopes. Dry pond facilities shall be designed and constructed so that complete drainage can be achieved following the rainfall or runoff event. The bottom slope shall be constructed in the configuration of a geometric plane with a minimum slope of one one-hundredths (0.01) feet per foot. Any dry pond facility required for a residential subdivision shall be allowed a bottom slope at a minimum of five one-thousandths (0.005) feet per foot if a minimum six (6) feet concrete pilot channel is installed across the entire length of the pond or a minimum of two (2) percent slope is installed if one (1) of the following conditions occur: (1) The pond facility is a minimum of three (3) acres in size and is dedicated to and accepted by the city as a park facility; or (2) The pond facility is a minimum of one and five-tenths (1.5) acres in size, is dedicated to the applicable community association as a park facility, and has received approval of the plan as a park by the city planning and zoning commission during the subdivision review process. (d) Entry and exit of water. All water to be detained within the pond facility for a minimum a one hundred-year design with a one (1) foot free board shall enter and exit by backfilling at one (1) controlled location through a concrete energy dissipating structure. Such structure shall be located at the lowest point of elevation within the pond facility and designed to fill the pond at a minimum of the design rate. A pumped system may be approved by the city floodplain administrator if sufficient information is provided by a registered professional engineer demonstrating no alternative to a pumped system due to existing elevation restrictions. Design of said structure shall be approved by the city floodplain administrator. (e) Additional wet pond regulations. Wet pond facilities shall have a minimum sustained depth of no less than four (4) feet of water. Concrete bulkheads shall be constructed to contain and surround the entire permanent water surface. Said permanent water surface shall be kept in a constant state of agitation by means of aerator devices, fountains or other approved devices. The number of such devices shall be determined by the city floodplain administrator. Pond design will include approved safety features to allow exit from the pond. (f) Grass establishment. Dry pond facilities shall be required to establish a solid sod grass cover on all side slopes and on bottoms. Wet pond facilities shall establish solid sod grass cover only above the permanent water surface. The nonsloped portion of a maintenance berm may be sprigged or hydro-mulched or solid sodded and the developer shall specify grass variety on the construction plans. (g) Fencing. Fencing of any kind shall be specifically disallowed surrounding or within a pond facility. (h) Screening. Dry pond facilities shall be required to provide a landscaped screening area a minimum of five (5) feet in width to screen the pond facility from view of all public rights-of-way. The screening area shall be required abutting all maintenance berms located between the pond facility and the street right-of-way. The method of required screening is defined in section 9-196(b). (i) Pond location. Pond facilities shall be located to the rear of a building unless deemed necessary by the director such that the resulting building screens portions of the pond facility from view of all street rights-of-way. (j) Miscellaneous. No permanent structures or landscaping shall be permitted within a pond facility. (k) Pond Setbacks. All ponds shall be setback a minimum fifteen (15) feet from all structures and ten (10) feet from all property lines.
(Ord. No. 20-186, § 1(Exh. 1), 1-5-21)
Ask a question about Pasadena law
Corpus searches the Pasadena sections it holds and shows the ones that match, with their citations. Free, no sign-in.