11.79.260 - Inlets.

A. Number of Inlets. Multiple inlets must be provided; so spaced that each inlet will serve a linear distance of not more than fifteen (15) feet, however, if directional inlets are used, the number of inlets shall be based on either one (1) inlet per six hundred square feet of pool area or one inlet per fifteen thousand gallons of pool capacity, whichever is greater. B. Orifice Design. Each inlet shall be designed as an orifice subject to adjustment or with an individual gate valve to permit adjustment of water volume. Discharge velocity must be sufficient to ensure distribution of disinfectant residual throughout the pool.

(1994 C., § 11.79.260; Ord. No. 65567, § 26, 2002.)