33.39 - 1202.4 .1 and R408.3.1 Floor Surface, Crawl space and Sub-basements.
Section 1202.4.1 and R408.3.1 Floor surface, crawl space, and sub-basements is hereby added as follows: Section R408.3.1 Floor surface, crawl space, and subbasements. All crawl space or sub- basement floors shall be capped with a minimum of 1-1/2 inches of concrete over 6-mil vapor barrier. Said concrete mixture shall be a minimum of 1500-PSI strength. Section 1202.41 (add Number 8) Floor surface, crawl space, and subbasements. All crawl space or sub- basement floors shall be capped with a minimum of 1-1/2 inches of concrete over 6-mil vapor barrier. Said concrete mixture shall be a minimum of 1500- PSI strength. (005-26)