For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 33.39 — 1202.4 .1 and R408.3.1 Floor Surface, Crawl space and Sub-basements

Cedar Rapids, Iowa, Municipal Code (Supp. No. 25, Update 1: codified through Ordinance No. 025-26, passed July 28, 2026) · Cedar Rapids Municipal Code § 33.39

Corpus is an independent public-information project, not the official City of Cedar Rapids website. Stable reference: corpuslaw.us/code/58ae5acc-2efb-4da5-b587-2448f5fed047

33.39 - 1202.4 .1 and R408.3.1 Floor Surface, Crawl space and Sub-basements.

Section 1202.4.1 and R408.3.1 Floor surface, crawl space, and sub-basements is hereby added as follows: Section R408.3.1 Floor surface, crawl space, and subbasements. All crawl space or sub- basement floors shall be capped with a minimum of 1-1/2 inches of concrete over 6-mil vapor barrier. Said concrete mixture shall be a minimum of 1500-PSI strength. Section 1202.41 (add Number 8) Floor surface, crawl space, and subbasements. All crawl space or sub- basement floors shall be capped with a minimum of 1-1/2 inches of concrete over 6-mil vapor barrier. Said concrete mixture shall be a minimum of 1500- PSI strength. (005-26)

Ask a question about Cedar Rapids law

Corpus searches the Cedar Rapids sections it holds and shows the ones that match, with their citations. Free, no sign-in.