Sec. 34-453. - Same—Requirements for systems.

It shall hereafter be unlawful for any person to construct a septic tank system that does not conform to the following minimum requirements: (1) Septic tank. a. Location. The tank shall be located not less than ten (10) feet from any property line, not less than five (5) feet from the foundation of any structure and not less than fifty (50) feet from any water well. b. Liquid capacity. The minimum liquid capacity for single-family dwellings shall be based on the number of bedrooms in the dwelling as follows: 2 bedrooms or less ..... 500 gallons 3 bedrooms ..... 600 gallons 4 bedrooms ..... 750 gallons For capacities other than single-family residences, the director of public health will determine the minimum capacity of the septic tank. The liquid depth of any tank or compartment thereof shall not be less than two and one-half (2½) feet nor more than six and one-half (6½) feet. When multicompartment tanks are used the inlet compartment shall have a liquid capacity of not less than two hundred and fifty (250) gallons. The liquid capacity shall be increased by fifty (50) percent when household garbage grinders discharge into the system. c. Scum storage. Scum storage volume (space between the liquid surface and the top of the tank) shall be not less than twelve (12) inches. d. Inlet baffle. The inlet baffle shall extend not less than six (6) inches below the liquid surface and not less than four (4) inches above the liquid surface. e. Outlet baffle. The outlet baffle shall extend not less than twelve (12) inches below the liquid surface and not less than six (6) inches above the liquid surface. The outlet shall not extend above the level of the inlet nor more than three (3) inches below the level of the inlet. f. Multicompartment tanks. When multicompartment tanks are used, a connection between compartments with a minimum diameter of four (4) inches shall be provided, and the inlet and outlet baffle submergency shall conform to the specifications for a single-compartment tank. g. Passage of waste. All kitchen waste, laundry waste and sewage shall pass through the septic tank before being discharged into the absorption field. h. Construction. The tank shall be constructed of reinforced concrete or metal such as to ensure watertightness and prevent the entrance of rainwater, surface drainage or groundwater Metal tanks shall comply with commercial standard 177-51 of the United States Department of Commerce. i. Manholes. All septic tanks shall be provided with manholes, removable lids or removable top sections. If a manhole is used, it shall be placed over the inlet and an inspection hole shall be placed over the outlet. (2) Distribution box. A distribution box of sufficient size to accommodate the necessary disposal lines shall be constructed at the head of each disposal field. a. Each disposal line shall be connected separately to the distribution box and shall not be subdivided. b. The invert of all outlets shall be level and the inlet invert shall be at least one (1) inch above the outlets. c. The outlet inverts shall be from four (4) to six (6) inches above the floor in lieu of a baffle for the purpose of securing equal distribution. d. Metal distribution boxes shall comply with commercial standard 177-51 of the United States Department of Commerce. (3) Location of absorption field. The absorption field shall be not less than one hundred and fifty (150) feet from any water well and not less than ten (10) feet from any dwelling or property line. (4) Minimum length of disposal line. All septic tank systems shall be provided with a minimum of disposal line based on the results of the percolation tests as follows. (A minimum of one hundred (100) linear feet of four-inch drainpipe shall be provided per installation.): Percolation rate time required for water to fall one inch in minutes | Linear feet of four-inch drainpipe per bedroom, without garbage grinder or automatic washer 2 or less | 34 3 | 40 4 | 47 5 | 50 10 | 67 15 | 77 30 | 100 45 | 120 60 | 134 When automatic washers discharge into the system, the minimum length of absorption field shall be increased by thirty-six (36) percent, and when garbage grinders discharge into the system the minimum length of absorption field shall be increased by twenty (20) percent. When both automatic washers and garbage grinders discharge into the system, the minimum length of absorption field shall be increased by sixty-six (66) percent. (5) Construction of disposal line trenches. All disposal line trenches shall have a minimum bottom width of eighteen (18) inches. The minimum distance of disposal line trenches center to center shall be six (6) feet. The grade of the disposal line trenches shall not exceed four (4) inches per one hundred (100) feet. The disposal field tile shall be laid one-fourth-inch open joints on a grade not to exceed four (4) inches per one hundred (100) feet. All open joints shall be protected on top by asphalt-treated building paper. There shall be a minimum of six (6) inches of gravel underneath disposal tile and two (2) inches over the tile, covering the entire width of the trench. The gravel shall be clean-washed, varying in size from one-half (½) to two and one-half (2½) inches. A layer of straw or absorbent paper shall be placed over the top of the gravel before the backfill is added. A minimum of twelve (12) inches of backfill shall be placed over the straw or absorbent paper. The maximum length of any disposal line shall not exceed one hundred (100) feet.

(Code 1950, § 58-6; Ord. No. 21416, § 4, 6-23-55; Code 1959, § 18-73; Ord. No. 80574, § 11, 8-4-94)

Ask a question about San Antonio law

Corpus searches the San Antonio sections it holds and shows the ones that match, with their citations. Free, no sign-in.