HOSPITALS AND CLINICS
Mesa City Code § 11-31-15
in effect11-31-15: - HOSPITALS AND CLINICS
Hospitals and Clinics, as described in Section 11-86-3 shall be located, developed, and operated in compliance with the land use regulations in Article 2 and the following standards:
A. Patient Entrances: Patient entrances shall:
1. Be clearly distinctive from the remainder of the building, and be readily visible from the public Street;
2. Be identified by directional signage in conformance with requirements of Article 5;
3. Include an extended foundation base to provide a patient drop-off area of a minimum 900 sq. ft., extending a minimum 20-feet measured perpendicular from the patient entrance door "See FIGURE 11-31-15.A & 11-31-15.B"; and
4. Pedestrian connections within parking areas, to other buildings on site, and to the public Street and transit shall follow the requirements of Section 11-30-8, Pedestrian Connections and Section 11-32-4(G)3, Pedestrian Access.
[image omitted; see the official code]
FIGURE 11-31-15.A: HOSPITALS AND CLINICS
[image omitted; see the official code]
FIGURE 11-31-15.B: PATIENT ENTRANCES
B. Emergency Room Access. Emergency room access shall be separate and distinct from the patient entrance(s), with directional signage in conformance with the requirements of Article 5. Vehicle access drives leading to the Emergency Room shall be direct from the Street and separated from parking lanes and spaces by intervening buildings, extruded curbs and landscape islands. "See FIGURE 11-31-15.C and 11-31-15.D"
[image omitted; see the official code]
FIGURE 11-31-15.C.1: EMERGENCY ROOM ACCESS
[image omitted; see the official code]
FIGURE 11-31-15.D: EMERGENCY ROOM ACCESS
C. Storage of Liquid Chemicals and Bulk Materials. Liquid oxygen and other similar materials stored outdoors and in bulk shall be screened from ground-level view by the building, screen wall, or screen walls in combination with landscape materials. If landscape materials are used, the mature height of the plant according to ANA standards may be taken into consideration, provided the size of the tree at planting is a minimum of 36-inch box.
D. Heliports. "See Figure 11-31-15.A" Heliports associated with a hospital are permitted, and shall be located in a manner to minimize noise impacts on abutting residential uses, according to the following preferences:
1. First Preference: Ground on side of building opposite any abutting residential areas.
2. Second Preference: Roof level of building less than the highest point on side of building away from residential areas.
3. Third Preference: Roof at top of building.
Source: City of Mesa, Arizona, Mesa City Code and City Charter (Municode Library, library.municode.com)URL: https://library.municode.com/az/mesa/codes/code_of_ordinances?nodeId=COOR_TIT11ZOOR_ART4DERE_CH31STSPUSAC_11-31-15HOCLFetched: 11/1/2026