Freestanding sign standards.
Round Rock Zoning and Development Code, art. IX, § 8-78
in effectSec. 8-78. - Freestanding sign standards.
(a) The standards for freestanding signs shall be determined by the roadway adjacent to the lot or the special area in which the lot is located.
(b) The display of the property address number shall be required on the sign structure of freestanding monument and pylon signs, but shall not be counted in the calculation of sign display area.
(c) Determining eligibility for freestanding signs.
(1) Freestanding signs shall only be permitted for a business use.
(2) At least one freestanding monument sign shall be allowed per lot.
(3) Other types of freestanding signs may be permitted in lieu of a monument sign, depending on the type of sign and the size of the lot.
(4) Low-profile signs may be permitted in addition to monument and pylon signs.
(d) Determining the location of freestanding signs. The location of freestanding signs shall meet the following standards:
(1) A sign shall have a minimum front setback of three feet and a minimum side setback of five feet.
(2) A sign shall not be located in or project over a public utility easement unless authorized by all applicable utility providers and the city.
(3) Signs shall not be located in parking spaces, drive aisles or any other areas that impede vehicular movement or maneuverability.
(4) Any sign located within a sight visibility triangle shall be no more than three feet in height.
(5) Signs shall be located within the same lot or multi-occupant center as the business use, except as expressly exempted in this chapter.
(6) No freestanding sign or any projection of said sign shall be in or project over a public right-of-way.
(7) Where the front setback of a building is less than ten feet, freestanding signs shall meet the freestanding sign size and type allowed for OS and DT special areas.
(8) Placement of signs shall meet all other requirements associated with this Code.
(e) Number and spacing requirements for freestanding signs.
(1) The number of freestanding signs varies depending on the size of the lot and the length of a site's frontage on a roadway.
(f) All non-rigid plastics shall have a minimum five-year warranty and are only permitted on the face of a cabinet sign.
(g) Electronic messaging centers (EMCs)/changeable message. Changeable message using EMCs shall meet the following requirements:
(1) Standards for EMC signs are provided by sign type.
(2) EMC signs shall only be permitted on freestanding signs, with the exception of theaters which are allowed to place EMCs on buildings.
(3) EMCs are prohibited on neighborhood roads, or in OS and DT special areas, with the exception of community facilities, schools, places of worship, and fuel station pricers.
(4) Except as provided in subsections (5) and (6) below, one EMC sign is permitted per lot.
(5) One EMC sign is permitted per multi-occupant center of less than five acres.
(6) One EMC sign is permitted per road frontage for a multi-occupant center of five acres or more.
(7) EMCs shall not change their message more than once every eight seconds and shall not be animated. Transitions shall be static/instant, with a transition time of one second or less.
(8) The illuminance of an EMC shall be measured with an illuminance meter set to measure foot candles accurate to at least two decimals. Illuminance shall be measured with the EMC off, and again with the EMC displaying a white image for a full color capable EMC, or a solid message for a single-color EMC. All measurements shall be taken perpendicular to the face of the EMC using the following formula:
Measurement distance = | √[(sign display area of EMC) x 100]
The difference between the off and solid-message measurements using the EMC measurement distance formula shall not exceed 0.3 foot candles at night.
(9) All EMCs shall have automatic dimming capability that adjusts the brightness to the ambient light at all times of the day and night and shall be able to be adjusted to comply with the 0.3 foot candle measurements in subsection (8) above.
(10) All EMCs are prohibited from being located within five feet of a sight visibility triangle regardless of height or size.
(h) Sign standards for monument signs.
Monument: On a Lot Less than Five Acres
Site Criteria | Every lot is entitled to a monument sign with the exception of properties with MU-L zoning, which may have any other freestanding sign type permitted in the DT special area.
Number and Spacing of Signs | One per road frontage.
Sign Size By Road Type or Special Area | Freeway | Commercial Road | Neighborhood Road | Special Area - OS; DT
Max. Sq. Ft. of sign display area | 150 | 75 | 50 | 36 0 for MU-L
Maximum Height | 18' | 12' | 6' | 6' 0 for MU-L
Sign Structure Requirements - Bases, Caps, Proportion, etc. | No less than 75 percent of the width of the sign shall be in contact with the ground. For signs less than six feet tall, a base shall not be required; however, the signs shall meet the sign display area requirements for a surround. For signs between six and 12 feet in height, a minimum two-foot-high base shall be required and must be constructed of stone, stucco, brick or other materials approved by the Zoning Administrator unless the cabinet sign is made entirely of metal then the base may be made of metal and the structure can be one piece. For all signs having a height of greater than 12 feet, a minimum three-foot-high base shall be required and must be constructed of stone, stucco, brick or other material approved by the Zoning Administrator. For a required base, the base height shall be no more than one-third the total sign height. The applicant shall be required to provide a structural drawing completed by an engineer demonstrating a windload of 105 mph or greater for any monument sign greater than four feet and up to ten feet in height. Signs greater than ten feet in height shall demonstrate a windload of 115 mph or greater.
Sign Display Area | Items of information shall be surrounded by a margin of ten percent of the smaller dimension of the sign display area of any panel contained in a freestanding sign. Freestanding cabinet signs shall have a surround around the cabinet so the cabinet is integrated with the base. The cabinet shall be flush with or inset from the sign surround but may accommodate a two inch retainer and service disconnect switch where necessary. The integration of the cabinet and the base shall have the appearance of one structure. Cabinet signs made of metal, including the base, are exempt from the requirement to provide a surround. If a logo is attached to any portion of the display area and the base, then the logo shall not require a surround. Building address shall not be computed as part of the display area.
Materials | Wood that is painted or sealed, painted or enameled metal, stone, brick, simulated stone, stucco, plastics and/or a combination thereof. Plastics of any kind are prohibited as a component of the sign structure for any monument sign. All non-rigid plastics shall have a minimum five year warranty and are only permitted on the face of a cabinet sign. Alternate materials that resemble permitted materials or match the materials on the primary structure may be considered by the Zoning Administrator. Plastics of any kind shall not be visible in OS and DT special areas.
Lighting | External illumination and illumination by halation shall be permitted. Internal illumination shall be allowed, however, internally illuminated signs on neighborhood roadways shall consist of individual letters or routed cabinets with an opaque background with only the items of information lit or translucent. In special areas, internal illumination shall be prohibited. All internal lighting shall have concealed conduits. All external lighting sources shall be shielded from adjacent properties and rights-of-way.
Electronic Messaging Center | EMCs shall display text only for up to 40 percent of the sign display area. EMCs shall not be allowed on neighborhood roads or in OS and DT special areas with the exception of use for community services, schools, places of worship, or fuel station pricers. One EMC sign is permitted per multi-occupant center.
Monument: On a Lot of Five Acres or More
Site Criteria | For a lot that is five acres or more. Minimum of 50 linear feet of property/lot frontage required.
Number and Spacing of Signs | If more than one sign, they shall be separated a minimum of 400 feet from any other monument, pylon, pillar, post/panel or armature sign on a site.
Sign Size By Road Type or Special Area | Freeway | Commercial Road | Neighborhood Road | Special Area - OS; DT
Max. Sq. Ft. of sign display area | 200 | 120 | 60 | 36 square feet on neighborhood roads and 100 square feet on commercial roads and freeways in special area
Maximum Height | 30' | 20' | 6' | 6 feet on neighborhood roads and 10 feet on commercial roads and freeways in special area
Sign Structure Requirements - Bases, Caps, Proportion, etc. | No less than 75 percent of the width of the sign shall be in contact with the ground. For signs less than six feet tall, a base shall not be required; however, the signs shall meet the sign display area requirements for a surround. For all signs between six and 12 feet in height, a minimum two-foot-high base shall be required and must be constructed of stone, stucco, brick, or other material approved by the Zoning Administrator. For all signs having a height of greater than 12 feet, a minimum three-foot-high base shall be required and must be constructed of stone, stucco, brick, or other material approved by the Zoning Administrator. The base height shall be no more than one-third of the total sign height. The applicant shall be required to provide a structural drawing completed by an engineer demonstrating a windload of 105 mph or greater for any monument sign greater than four feet in height and up to ten feet in height. Signs greater than ten feet in height shall demonstrate a windload of 115 mph or greater.
Sign Display Area | Items of information shall be surrounded by a margin of ten percent of the smaller dimension of the sign display area of any panel contained in a freestanding sign. Freestanding cabinet signs shall have a surround around the cabinet so the cabinet is integrated with the base. The cabinet shall be flush with or inset from sign surround but may accommodate a two-inch retainer and service disconnect switch where necessary. The integration of the cabinet and the base shall have the appearance of one structure. Cabinet signs made of metal, including the base, are exempt from the requirement to provide a surround. If a logo is attached to any portion of the display area and the base, then the logo shall not require a surround. Building address shall not be computed as part of the sign display area.
Materials | Wood that is painted or sealed, painted or enameled metal, stone, brick, simulated stone, stucco, plastics and/or a combination thereof. Plastics or similar material of any kind are prohibited as a component of the sign structure for any monument sign. All non-rigid plastics shall have a minimum five-year warranty and are only permitted on the face of a cabinet sign. Alternate materials that resemble permitted materials or match the materials on the primary structure may be considered by the Zoning Administrator. Plastics of any kind shall not be visible in OS and DT special areas.
Lighting | External illumination and illumination by halation shall be permitted. Internal illumination shall be allowed, however, internally illuminated signs on neighborhood roadways shall consist of individual letters or routed cabinets with an opaque background with only the items of information lit or translucent. In special areas, internal illumination shall be prohibited. All internal lighting shall have concealed conduits. All external lighting sources shall be shielded from adjacent properties and rights-of-way.
Electronic Messaging Center (EMC) | EMCs shall display text only for up to one-third of the sign display area, except that fuel station pricers, community services, schools, and places of worship may utilize 50 percent of the total sign display area. EMCs shall not be allowed on neighborhood roads or in OS and DT special areas with the exception of use for community services, schools, places of worship, and fuel station pricers. One EMC sign is permitted per road frontage for a multi-occupant center.
Low-Profile Sign
Site Criteria | For a lot that is five acres or more.
Number and Spacing of Signs | Low-profile signs shall be permitted in addition to a monument or pylon sign where there is a minimum of 200 feet of contiguous lot frontage without another freestanding sign.
Sign Size By Road Type or Special Area | Freeway | Commercial Road | Neighborhood Road | Special Area - OS; DT
Max. Sq. Ft. of sign display area | 40 | 25 | 0 | 0
Maximum Height | 6' | 6' | 0 | 0
Sign Structure Requirements - Bases, Caps, Proportion, etc. | One hundred percent of the width of the sign shall be in contact with the ground. A one-foot-high base shall be required and must be constructed of stone, stucco, brick or other material approved by the Zoning Administrator. Cabinet signs made entirely of metal can include a metal base, and the structure may be one piece. The applicant shall be required to provide a structural drawing completed by an engineer demonstrating a windload of 105 mph or greater for any low-profile sign greater than four feet in height.
Sign Display Area | Items of information shall be surrounded by a margin of ten percent of the smaller dimension of the sign display area of any panel contained in a freestanding sign. Freestanding cabinet signs shall have a surround around the cabinet, and the cabinet shall be flush with or inset from sign surround but may accommodate a two-inch retainer and service disconnect switch where necessary. The integration of the cabinet and the base shall have the appearance of one structure. Building address shall not be computed as part of the sign display area. Cabinet signs made entirely of metal, including the base, are exempt from the requirement to provide a surround. If a logo is attached to any portion of the display area and the base, then the display area shall not require a surround.
Materials | Wood that is painted or sealed, painted or enameled metal, stone, brick, simulated stone, stucco, plastics and/or a combination thereof. Where an alternate material is approved for a monument sign, the same material may be used for a low profile sign.
Lighting | External illumination, internal illumination, and illumination by halation shall be permitted. All external lighting sources shall be shielded from adjacent properties and rights-of-way.
Electronic Messaging Center (EMC) | Prohibited.
(i) Sign standards for pylon signs.
Pylon: On a Lot Less Than Five Acres
Site Criteria | For a lot on a freeway that is less than five acres or for a sign on a commercial road within 500 feet of the main lanes of a freeway. Minimum of 50 linear feet of property/lot or multi-occupant center frontage required.
Number and Spacing of Signs | One per site in lieu of another allowable freestanding sign.
Sign Size By Road Type or Special Area | Freeway | Commercial Road | Neighborhood Road | Special Area - OS; DT
Max. Sq. Ft. of sign display area | 120 | 100 only if sign is entirely within 500 ft. of the main lanes of a freeway | 0 | 0
Maximum Height | 50' | 50 ft. only if sign is entirely within 500 ft. of the main lanes of a freeway. | 0 | 0
Sign Structure Requirements - Bases, Caps, Proportion, etc. | Two poles shall be required for new pylon signs displaying items of information for more than one occupant. Existing pylon signs with only one pole are not required to add a second pole. The applicant shall be required to provide a structural drawing completed by an engineer demonstrating a windload of 115 mph or greater for any pylon sign greater than four feet in height.
Sign Display Area | Items of information shall be surrounded by a margin of ten percent of the smaller dimension of the sign display area of any panel contained in a freestanding sign. Cabinet signs shall be flush with or inset from sign surround but may accommodate a two-inch retainer and service disconnect switch where necessary. Building address shall not be computed as part of the sign display area.
Materials | Wood that is painted or sealed, painted or enameled metal, stone, brick, simulated stone, stucco, plastics and/or a combination thereof. All non-rigid plastics shall have a minimum five-year warranty and are only permitted on the face of a cabinet sign. Plastics of any kind shall not be visible in OS and DT special areas.
Lighting | External illumination, internal illumination, and illumination by halation shall be permitted. All internal lighting shall have concealed conduits. All external lighting sources shall be shielded from adjacent properties and rights-of-way.
Electronic Messaging Center (EMC) | Up to 50 percent of the sign display area may be an EMC.
Pylon: On a Lot of Five Acres or More
Site Criteria | For lots of five acres or more on a freeway or for a sign on a commercial road within 500 feet of the main lanes of a freeway. Minimum of 50 linear feet of property/lot or multi-occupant center frontage required.
Number and Spacing of Signs | One per frontage permitted every 400 feet with additional monument signs allowed. Total number of signs shall not exceed total number of driveway entrances on the site.
Sign Size By Road Type or Special Area | Freeway | Commercial Road | Neighborhood Road | Special Area - OS; DT
Max. Sq. Ft. of sign display area | 200 | 100 only if sign is entirely within 500 ft. of the main lanes of a freeway | 0 | 0
Maximum Height | 50' | 50 ft. only if sign is entirely within 500 ft. of the main lanes of a freeway | 0 | 0
Sign Structure Requirements - Bases, Caps, Proportion, etc. | Two poles shall be required for new pylon signs displaying items of information for more than one occupant. Existing pylon signs with only one pole are not required to add a second pole. The applicant shall be required to provide a structural drawing completed by an engineer demonstrating a windload of 115 mph or greater for any pylon sign greater than four feet in height.
Sign Display Area | Items of information shall be surrounded by a margin of ten percent of the smaller dimension of the sign display area of any panel contained in a freestanding sign. Cabinet signs shall be flush with or inset from sign surround but may accommodate a two-inch retainer and service disconnect switch where necessary. Building address shall not be computed as part of the sign display area.
Materials | Wood that is painted or sealed, painted or enameled metal, stone, brick, simulated stone, stucco, plastics and/or a combination thereof. All non-rigid plastics shall have a minimum five-year warranty and are only permitted on the face of a cabinet sign. Plastics of any kind shall not be visible in OS and DT special areas.
Lighting | External illumination, internal illumination, or illumination by halation shall be permitted. All internal lighting shall have concealed conduits. All external lighting sources shall be shielded from adjacent properties and rights-of-way.
Electronic Messaging Center (EMC) | Up to 50 percent of the sign display area may be an EMC.
(j) Sign standards for pillar signs.
Pillar Signs
Site Criteria | For a single occupant on one or more lots with frontage on a freeway or commercial road.
Number and Spacing of Signs | One may be used in lieu of a permitted monument or pylon sign.
Sign Size By Road Type or Special Area | Freeway | Commercial Road | Neighborhood Road | Special Area - OS; DT
Max. Sq. Ft. of sign display area | 120 | 48 | 0 | 0
Maximum Height | 21' | 12' | 0 | 0
Sign Structure Requirements - Bases, Caps, Proportion, etc. | The entire sign structure shall be considered as sign display area. The entire base of sign shall be in contact with the ground and the sign structure, which includes the sign display area within its shape, shall be a continuous shape from the bottom to the top of the sign. The width of the sign shall be no more than one-third of the measurement of its height. The applicant shall be required to provide a structural drawing completed by an engineer demonstrating a windload of 105 mph or greater for any pillar sign greater than four feet in height and up to ten feet in height. Signs greater than ten feet in height shall demonstrate a windload of 115 mph or greater.
Sign Display Area | Items of information shall be surrounded by a margin of ten percent of the smaller dimension of the sign display area of any panel contained in a freestanding sign. Building address shall not be computed as part of the sign display area.
Materials | Painted or enameled metal, plastic or masonry.
Lighting | External illumination or internal illumination shall be permitted. All internal illumination shall have concealed conduits. All external lighting sources shall be shielded from adjacent properties and rights-of-way.
Electronic Messaging Center (EMC) | Prohibited.
(k) Sign standards for post/panel signs.
Post/Panel Signs
Site Criteria | Shall be permitted in lieu of a monument sign.
Number and Spacing of Signs | One per lot in lieu of a monument sign.
Sign Size By Road Type or Special Area | Freeway | Commercial Road | Neighborhood Road | Special Area - OS; DT
Max. Sq. Ft. of sign display area | 0 | 16 | 16 | 16
Maximum Height | 0 | 6' | 6' | 6'
Sign Structure Requirements - Bases, Caps, Proportion, etc. | The clearance of the sign from the finished grade to the bottom of the sign display area shall be no greater than four feet. Sign shall be supported by two freestanding posts so that the bottom edge of the sign face is not in direct contact with the ground. The width of a sign's supports shall be the same from the ground to the top of the sign and shall be an integral part of the design of the entire sign. No portion of the sign display area shall extend beyond a sign's panel or beyond the posts.
Sign Display Area | One panel shall be permitted per occupant plus one additional panel. The total area of all panels shall be considered to be the sign display area, and the total square footage for all panels shall not exceed the maximum square footage of sign display area. Items of information shall be kept outside a margin measured as ten percent of the smallest dimension of the panel.
Materials | Posts shall be greater in thickness than the width of the sign display area and be made from painted or sealed wood/composite wood material, painted or enameled metal, stone or brick. Sign display area shall be made of wood/composite wood material that is painted or sealed, or painted or enameled metal.
Lighting | Only shielded external illumination shall be permitted.
Electronic Messaging Center (EMC) | Prohibited.
(l) Sign standards for armature signs.
Armature Signs
Site Criteria | Shall be permitted in lieu of a monument sign except for on freeways. Sign shall be cantilevered from one post so that the bottom edge of the sign face is not in direct contact with the ground. The sign's supports shall be an integral part of the design of the entire sign. No portion of the sign display area shall extend beyond the sign's panel.
Number and Spacing of Signs | One per lot in lieu of a monument sign.
Sign Size By Road Type or Special Area | Freeway | Commercial Road | Neighborhood Road | Special Area - OS; DT
Max. Sq. Ft. of sign display area | 0 | 16 | 16 | 16
Maximum Height | 0 | 8' | 6' | 6'
Sign Structure Requirements - Bases, Caps, Proportion, etc. | The applicant shall be required to provide a structural drawing completed by an engineer demonstrating a wind load of 105 mph or greater for any armature sign greater than six feet in height.
Sign Display Area | The entire panel shall be considered to be the sign display area. Items of information shall be kept outside a margin measured as ten percent of the smallest dimension of the panel.
Materials | Posts shall be made from painted or sealed wood/composite wood material or painted or enameled metal. Sign display area shall be made of wood/composite wood material that is painted or sealed, or painted or enameled metal.
Lighting | Only shielded external illumination shall be permitted.
Electronic Messaging Center (EMC) | Prohibited.
(Ord. No. O-2022-234, § II, 7-14-2022; Ord. No. O-2025-277, § XVI, 10-23-2025)