Special purpose building sign standards.
Round Rock Zoning and Development Code, art. IX, § 8-77
in effectSec. 8-77. - Special purpose building sign standards.
(a) Vehicle service canopy signs.
Vehicle Service Canopy Signs
Building Criteria | Signs shall be permitted on a canopy that covers a vehicle service area that is an accessory structure not attached to a building.
Number, Amount of Building Signage/Items of Information | Flat-roofed canopy: Vehicle service canopy maximum sign display area shall be considered as accessory signs and shall be calculated separately from the maximum building sign display area for wall signs. Pitched-roof canopy: Up to two hanging signs with a maximum sign display area of ten square feet each shall be permitted on a pitched canopy.
Sign Size By Road Type or Special Area per Occupant Frontage | Freeway | Commercial Road | Neighborhood Road | Not Facing a Public ROW | Special Area - OS; DT | Sharing Property Line with SF or TF Zoned Lot
Percent Coverage on face of all flat-roof canopy types | 25 | 25 | 25 | 0 | 25 | 0
Maximum square feet of sign display area attached to a pitched-roof canopy per occupant frontage | 10 | 10 | 10 | 10 | 10 | 0
Placement (on building) | Signs shall be placed on or be an integral part of the face of a flat-roofed canopy. Hanging signs shall be permitted to hang from an eave of a pitched canopy or may be affixed to the fascia on the non-gabled sides of the canopy. No sign shall extend above the top edge of a flat roof or peak of a pitched roof.
Materials & Design | All surfaces of a sign shall be finished. All signs shall be constructed of rigid materials such as wood, metal, and plastic, or an equivalent material.
Lighting | Internal illumination shall be permitted with the exception of in OS and DT special areas. External illumination and illumination by halation are permitted.
Electronic Messaging Center (EMC) | Prohibited.
(b) Parking garage signs.
Parking Garage Signs
Building Criteria | Signs shall be permitted on any structure used solely for the purposes of parking.
Number, Amount of Building Signage/Items of Information | Parking garage maximum sign display area shall be considered as accessory signs and shall be calculated separately from the maximum building sign display area for wall signs.
Sign Size By Road Type or Special Area per Occupant Frontage (Amount allowed shall be whichever measurement is less) | Freeway | Commercial Road | Neighborhood Road | Not Facing a Public ROW | Special Area - OS; DT | Sharing Property Line with SF or TF Zoned Lot
Maximum square feet of sign display area | 300 | 300 | 200 | 100 | 200 | 0
Square feet of sign display area per one linear foot of occupant frontage | 0.5 | 0.5 | 0.5 | 0.25 | 0.25 | 0
Placement (on building) | Parking garage signs shall be placed flush to a facade and a distance of no less than ten percent of the smallest dimension of the sign display area shall be maintained as a margin around the entire sign display area. Signs are prohibited above any wall plane of a garage.
Materials & Design | Cabinet signs are prohibited for external commercial messages on the exterior of the structure. Cabinet signs may be used for incidental signs.
Lighting | Internal illumination, external illumination and illumination by halation are permitted.
Electronic Messaging Center (EMC) | Prohibited except for incidental signs.
(c) Banners. Banners shall meet the following standards:
(1) A sign permit shall be required for the display of all banners.
(2) No more than one banner shall be displayed at a time for each occupancy, including new occupancy banners.
(3) Banners shall not exceed 15 square feet in area, unless the occupant frontage onto which the banner shall be placed exceeds 80 linear feet, then a banner may have a maximum area of 40 square feet.
(4) Banners may be placed in the following locations:
a. The entire banner must be attached and parallel with a wall and shall not cover any part of a building's windows or doors. In cases where the architecture of the building cannot accommodate a banner, other locations may be considered by the Zoning Administrator.
b. In cases where a single occupant business use is located a minimum of 75 feet from the edge of the right-of-way or has other visibility issues, the Zoning Administrator may consider a freestanding banner location. This shall not apply to single occupants in a multi-tenant center.
(5) Banners promoting an aspect of a business may only be attached to the building or unit which houses the business.
(6) A banner permit may be issued for between one and 12 consecutive weeks. The duration of all banner permits at an establishment may not exceed a total of 12 weeks in a 12-month period.
(7) Banners shall not be tattered, torn or faded and shall remain tautly attached.
(8) If a banner is found to be in violation of this section for 30 days or more, a permit for any type of banner shall not be issued for 12 months to the occupant from the date of the original violation.
(d) Banners for a new occupancy or use. Banners for a new occupancy or use shall meet the following standards:
(1) A sign permit shall be required. A separate fee for the banner for a new occupancy or use shall not be required if the applicant concurrently submits a permit application for a permanent sign.
(2) One banner shall be allowed for each single occupancy structure or for each occupant frontage in a multi-occupant center or building and is prohibited to be displayed at the same time as a banner in subsection (c) above.
(3) Banners shall not exceed 40 square feet in area.
(4) The entire banner must be attached and parallel with the wall and shall not cover any part of a building's windows or doors. When a banner cannot be located as described above, alternative locations may be considered by the Zoning Administrator.
(5) Banners promoting an aspect of a business may only be attached to the building or unit which houses the business.
(6) A banner for new occupancy or use shall be allowed for a maximum of 90 days within the first three months of establishment of such new occupancy or use in lieu of a permanent sign. This banner shall be removed when a permanent sign is installed. The Zoning Administrator may approve extensions in weekly increments to accommodate delays in permanent sign installation.
(7) Banners shall not be tattered, torn or faded and shall remain tautly attached.
(8) If a banner is found to be in violation of this section for 30 days or more, a permit for any type of banner shall not be issued for 12 months to the occupant from the date of the original violation.
(e) Building scrim sign.
(1) A sign permit shall be required for a building scrim sign.
(2) One building scrim sign shall be permitted for a building that is at least two stories tall. One building at a time shall be permitted to display a scrim sign in a nonresidential development that would qualify for an area identification sign.
(3) A building scrim sign shall not be displayed for a period exceeding 60 consecutive calendar days per permit with a maximum of two permits issued in any consecutive 12-month period.
(4) Building scrim signs shall not be tattered, torn or faded and shall remain tautly attached.
(f) Building signs for temporary occupants of a business use. For building signs for temporary occupants, one sign may be permitted per occupant frontage of a business use occupying a space for seasonal use or similar. The total square footage shall be no larger than the square foot limit allowed for wall signs on a designated roadway not to exceed 64 square feet, and the flat panel size restriction for wall signs shall not apply. When the material is semi-rigid, all-weather material such as coroplast, the flat panel size shall be limited to 16 square feet. All other wall sign standards shall apply. The sign shall be displayed for a period not to exceed 120 days.
(g) Directory signs. For the purpose of identifying individual tenants in a building with multiple tenants, the total sign area for all panels in a directory sign shall not exceed six square feet.
(h) Home occupation sign. In areas zoned for SF-1, SF-2, SF-3, SF-D, or TF, for the purpose of identifying a customary home occupation, as defined in Sec. 2-93, one home occupation sign shall be permitted. Such sign shall be attached flat against the wall of the house and shall not exceed two square feet in surface area.
(i) Window signs. Window signs are allowed with the following conditions:
(1) Window sign display area shall not be included as part of the total signs display area of building signs.
(2) Total sign display area of all window signs on any elevation of a building shall not cover more than 50 percent of the glazing on an elevation.
a. Perforated vinyl (50/50) and translucent window coverage shall be considered to be window sign coverage.
b. No more than 50 percent of any window within four feet surrounding the main entrance shall be covered with window signs for visibility into and out of a business use.
(3) Window signs in OS and DT special areas shall not be illuminated with the exception of an incidental sign not to exceed two (2) square feet.
(j) Incidental building signs. For those incidental signs that are not internal to a site, the maximum allowable square footage of sign display area shall be less than or equal to 25 percent of the total wall sign area allowed per occupant frontage. Temporary signs made of material with less than a five-year warranty, such as, but not limited to, posters, shall be framed and have a protective cover over the sign display area.
(Ord. No. O-2022-234, § II, 7-14-2022; Ord. No. O-2025-277, § XV, 10-23-2025)
Source: City of Round Rock, Texas, Code of Ordinances (Municode Library, library.municode.com)URL: https://library.municode.com/tx/round_rock/codes/code_of_ordinances?nodeId=PTIIIZODECO_CH8ZODEST_ARTIXSI_S8-77SPPUBUSISTFetched: 11/16/2026
