§ 37.122 — Planting and irrigation plans
The Code of the City of Oceanside, California (Supp. No. 50: codified through Ordinance No. 26-OR0412-1, enacted June 17, 2026) · Oceanside City Code § 37.122
Corpus is an independent public-information project, not the official City of Oceanside website. Stable reference: corpuslaw.us/code/70b4156d-73c0-4d3e-b0ac-1d502854b0e9
Sec. 37.122. - Planting and irrigation plans.
(a) The planting and irrigation plans required by Section 37.120 shall be prepared by a licensed landscape architect, or other professional licensed by the state to do this work. The plans shall: (1) Include the MAWA for the plans, including the calculations used to determine the MAWA. The calculations shall be based on the formula in Section 37.126. (2) Include the ETWU for the plans, including the calculations used to determine the ETWU. The calculations shall be based on the formula in Section 37.127. (3) Include a statement signed under penalty of perjury by the person who prepared the plan that provides, "I am familiar with the requirements for landscape and irrigation plans contained in the City of Oceanside's Water Efficient Landscape Regulations. I have prepared this plan in compliance with those regulations, the Landscape Design Manual and the current City of Oceanside Landscape Development Manual. I certify that the plan implements those regulations to provide efficient use of water." (4) Demonstrate compliance with best management practices required by watershed protection, stormwater management and discharge control regulations. (5) Address fire safety issues and demonstrate compliance with applicable requirements for defensible space around buildings and structures and shall avoid the use of fire prone vegetation. (b) The planting plan shall meet the following requirements: (1) The plan shall include a list of all vegetation by common and botanical plant name, which exists in the proposed landscaped area. The plan shall state what vegetation will be retained and what will be removed. (2) The plan shall include a list of all vegetation by common and botanical plant name, which will be added to each landscaped area. No invasive plant species shall be added to a landscaped area. The plan shall include the total quantities by container size and species. If the applicant intends to plant seeds, the plan shall describe the seed mixes, applicable purity, germination specifications, slurry mix specification and tackifier information. (3) The plan shall include a detailed description of each water feature that will be included in the landscaped area. (4) The plan shall be accompanied by a drawing showing on a page or pages, the specific location of all vegetation, retained or planted, the plant spacing and plant size, natural features, water features, and hardscape areas. The drawing shall include a legend listing the common and botanical plant name of each plant shown on the drawing. (5) All plants shall be grouped in hydrozones and the irrigation shall be designed to deliver water to hydrozones based on the moisture requirements of the plant grouping. A hydrozone may mix plants of moderate and low water use or mix plants of high water use with plants of moderate water use. No high water use plants shall be allowed in a low water use hydrozone. The plan shall also demonstrate how the plant groupings accomplish the most efficient use of water. (6) The plan shall identify areas permanently and solely dedicated to edible plants. (7) The plan shall demonstrate that landscaping when installed and at maturity will be positioned to avoid obstructing motorists' views of pedestrian crossings, driveways, roadways and other vehicular travel ways. If the landscaping will require maintenance to avoid obstructing motorist's views, the plan shall describe the maintenance and the frequency of the proposed maintenance. (8) The plan shall avoid the use of landscaping with known surface root problems adjacent to a paved area, unless the plan provides for installation of root control barriers or other appropriate devices to control surface roots. (9) Plants in a transitional area shall consist of a combination of site adaptive and compatible native and/or non-native species. No invasive species shall be introduced or tolerated in a transitional area. The irrigation in a transitional area shall be designed so that no overspray or runoff shall enter an adjacent area that is not irrigated. (10) On a project other than a single-family residence, the plan shall identify passive and active recreational areas. (c) The irrigation plan shall meet the following requirements: (1) The plan shall show the location, type and size of all components of the irrigation system that will provide water to the landscaped area, including the controller, water lines, valves, sprinkler heads, moisture sensing devices, rain switches, quick couplers, pressure regulators, and backflow prevention devices. (2) The plan shall show the static water pressure at the point of connection to the public water supply and the flow rate in gallons, the application rate in inches per hour and the design operating pressure in pressure per square inch for each station. (3) The irrigation system shall be designed to prevent runoff, overspray, low-head drainage and other similar conditions where irrigation water flows or sprays onto areas not intended for irrigation. The plan shall also demonstrate how grading and drainage techniques promote healthy plant growth and prevent erosion and runoff. (4) The plan shall identify each area irrigated with recycled water. (5) The plan shall provide that any slope greater than twenty-five (25) percent will be irrigated with an irrigation system with a precipitation rate of .75 inches per hour or less to prevent runoff and erosion. As used in this article, twenty-five (25) percent grade means one (1) foot of vertical elevation change for every four (4) feet of horizontal length. An applicant may employ an alternative design if the plan demonstrates that no runoff or erosion will occur. (6) The plan shall provide that all wiring and piping under a paved area that a vehicle may use, such as a parking area, driveway or roadway, will be installed inside a PVC conduit. (7) The plan shall provide that irrigation piping and irrigation devices that deliver water, such as sprinkler heads, shall be installed below grade if they are within twenty-four (24) inches of a vehicle or pedestrian use area. The director may allow on-grade piping where landform constraints make below grade piping infeasible. (8) The plan shall provide that only low volume or subsurface irrigation shall be used to irrigate any vegetation within twenty-four (24) inches of an impermeable surface unless the adjacent impermeable surfaces are designed and constructed to cause water to drain entirely into a landscaped area. (9) The irrigation system shall provide for the installation of a manual shutoff valve as close as possible to the water supply. Additional manual shutoff valves shall be installed between each zone of the irrigation system and the water supply. (10) The irrigation system shall provide that irrigation for any landscaped area will be regulated by an automatic irrigation controller. (11) The irrigation system shall be designed with a landscape irrigation efficiency necessary to meet the MAWA. (12) The plan shall describe each automatic irrigation controller the system uses to regulate the irrigation schedule and whether it is a weather based system or moisture detection system. The plan shall depict the location of electrical service for the automatic irrigation controller or describe the use of batteries or solar power that will power valves or a smart controller.
(Ord. No. 10-OR0412-1, § 1, 5-26-2010)
Ask a question about Oceanside law
Corpus searches the Oceanside sections it holds and shows the ones that match, with their citations. Free, no sign-in.
