Section 10.030. - Character designations.
A. List. There are four (4) character designations established for the MX districts, as identified in Table 10-3. These designations govern allowed building types as well as required building and development patterns.
Table 10-3: MX District Character Designations
Map Symbol | General Character
-P | Pedestrian
-U | Urban
-V | Variable
-F | Flexible
B. Pedestrian Character Designation.
1. Intent. The -P, Pedestrian character designation is generally intended to be applied in locations where a high level of pedestrian orientation is present or desired, such as areas designated by the comprehensive plan as "main street" areas.
2. Allowed Building Types. The following building types are permitted in -P character zones (see building type definitions in Section 35.010):
a. Vertical mixed-use buildings.
b. Commercial buildings.
c. Civic/Institutional buildings.
d. Open space sites.
3. Lot and Building Regulations. The lot and building regulations of Table 10-4 apply to all new construction and building additions in -P character zones, except that civic/institutional buildings and open space sites are subject to -F character zone regulations (see Section 10.030-E). General exceptions to lot and building regulations and rules for measuring compliance can be found in Chapter 90. See Figure 10-3 for illustration of selected regulations. Existing buildings are exempt from compliance with build-to-zone (BTZ), ground floor ceiling height and transparency regulations.
Table 10-4: Lot and Building Regulations for -P Character Zones
Minimum Lot Area (sq. ft.) | 3,500
Minimum Lot Width (feet) | 25
Minimum Street Frontage (feet) | 20
Minimum Open Space per Unit (sq. ft.) | 100
Minimum Building Setbacks (feet)
Street | 0
Abutting R district | 10
Abutting nonresidential district | 0
Abutting alley | 5
Build-to-Zone (BTZ) (minimum/maximum in feet) See Section 90.110 for BTZ measurement | 0/20
Primary street BTZ (%) | 80
Secondary street BTZ (%) | 30
Min. Ground Floor Ceiling Height (feet) | 12
Minimum Transparency (%)
Ground floor | 50
Upper floors | 20
Min. Parking Setbacks (ft.) (see also Subsection 55-080C.)[1]
Primary street | 30
Secondary street or R zoning district | 10
Nonresidential zoning district | 0
Street-facing Entrance Required | Yes
See Figure 10-3 for illustration of selected regulations.
[1] Parking spaces, not including drive aisles, are prohibited between building and street right-of-way (see Figure 10-2) Parking structures are subject to Section 40.280.
Figure 10-2: Parking Prohibited between Building and Street Right-of-Way (-P Character Zones)
[image omitted; see the official code]
Figure 10-3: MX District Lot and Building Regulations (-P Character Zone)
[image omitted; see the official code]
C. Urban Character Designation.
1. Intent. Like the -P character designation, the -U, Urban character designation is generally intended to be applied in areas with high levels of walkability, but where a greater variety of building types are present or desired, such as in areas designated by the comprehensive plan as neighborhood, town and regional centers and along some plan-designated mixed-use corridors.
2. Allowed Building Types. The following building types are permitted in -U character zones (see building type definitions in Section 35.010):
a. Vertical mixed-use and mixed-use buildings.
b. Commercial buildings.
c. Apartment/Condo.
d. Townhouses.
e. Civic/Institutional buildings.
f. Open space sites.
3. Lot and Building Regulations. The lot and building regulations of Table 10-5 apply to all new construction and building additions in -U character zones, except that civic/institutional buildings and open space sites are subject to -F character zone regulations (see Section 10.030-E). General exceptions to lot and building regulations and rules for measuring compliance can be found in Chapter 90. Existing buildings are exempt from compliance with build-to-zone (BTZ), ground floor ceiling height and transparency regulations.
Table 10-5: Lot and Building Regulations for -U Character Zones
Minimum Lot Area (sq. ft.)
Townhouse | 1,600
Apartment/condo | 7,500
All other | 3,500
Minimum Lot Width (feet)
Townhouse | 20
Apartment/condo | 50
All other | 25
Minimum Street Frontage (feet) | 20
Minimum Open Space per Unit (sq. ft.)
Townhouse | 200
Apartment/condo/mixed-use | 100
Minimum Building Setbacks (feet)
Street | 0
Abutting R district | 10
Abutting nonresidential district | 0
Abutting alley | 5
Build-to-Zone (BTZ) (minimum/maximum in feet). See Section 90.110 for BTZ measurement | 0/20
Primary street BTZ (%) | 60
Secondary street BTZ (%) | 30
Min. Parking Setbacks (feet) (see also Subsection 55.080C.)[1]
Primary street | 30
Secondary street or R zoning district | 10
Nonresidential district | 0
Min. Ground Floor Ceiling Height (feet)
Vertical mixed-use, mixed-use, and commercial buildings | 12
Other buildings | -
Minimum Transparency (%)
Vertical mixed-use buildings
Ground floor | 40
Upper floors | 20
Commercial buildings and mixed-use buildings
Ground floor | 35
Upper floors | 20
Other buildings | 20
Street-facing Entrance Required | Yes
[1] Parking is prohibited between building and street right-of-way (see Figure 10-4). Parking structures are subject to Section 40.280.
Figure 10-4: Parking Prohibited between Building and Street Right-of-Way (-U Character Zones)
[image omitted; see the official code]
D. Variable character designation.
1. Intent. The -V, Variable character designation is generally intended to be applied in auto-oriented areas where a transition to greater levels of walkability are underway or desired. The regulations allow greater flexibility in the siting of buildings and parking areas by, for example, allowing more generous maximum building setbacks, which can be used for landscape and streetscape elements or limited amounts of parking.
2. Allowed building types. The following building types are permitted in -V character zones (see building type definitions in Section 35.010):
a. Vertical mixed-use buildings and mixed-use buildings.
b. Commercial buildings.
c. Apartment/Condo.
d. Townhouses.
e. Civic/Institutional buildings.
f. Open space sites.
3. Lot and Building Regulations. The lot and building regulations of Table 10-6 apply to all new construction and building additions in -V character zones, except that civic/institutional buildings and open space sites are subject to -F character zone regulations (see Section 10.030-E). General exceptions to lot and building regulations and rules for measuring compliance can be found in Chapter 90. See Figure 10-6 for illustration of selected regulations. Existing buildings are exempt from compliance with build-to-zone (BTZ), ground floor ceiling height and transparency regulations.
Table 10-6: Lot and Building Regulations for -V Character Zones
Minimum Lot Area (sq. ft.)
Townhouse | 1,600
Apartment/condo | 7,500
All other | 3,500
Minimum Lot Width (feet)
Townhouse | 20
Apartment/condo | 50
All other | 25
Minimum Street Frontage (feet) | 20
Minimum Open Space per Unit (sq. ft.)
Townhouse | 200
Apartment/condo/mixed-use | 100
Minimum Building Setbacks (feet)
Street | 0
Abutting R district | 10
Abutting nonresidential district | 0
Abutting alley | 5
Build-to-Zone (BTZ) (minimum/maximum in feet) See Section 90.110 for BTZ measurement | 0/110
Primary street BTZ (%) | 50
Secondary street BTZ (%) | 25
Min. Parking Setbacks (feet) (see also Subsection 55.080C.) [1]
Street or R zoning district | 10
Nonresidential zoning district | 0
Min. Ground Floor Ceiling Height (feet)
Vertical mixed-use, mixed-use and commercial buildings | 12
Other buildings | -
Minimum Transparency (%)
Vertical mixed-use buildings
Ground floor | 40
Upper floors | 20
Commercial buildings and mixed-use buildings
Ground floor | 35
Upper floors | 20
Other buildings | 20
Street-facing entrance required | Yes
See Figure 10-6 for illustration of selected regulations.
[1] A maximum of one double-loaded parking aisle (two (2) parking bays) is permitted between the building and street right-of-way (see Figure 10-5 and Figure 10-6). Parking structures are subject to Section 40.280.
Figure 10-5: Limited Parking between Building and Street Right-of-Way (-V Character Zones)
[image omitted; see the official code]
Figure 10-6: MX District Lot and Building Regulations (-V Character Zone)
[image omitted; see the official code]
E. Flexible Character Designation.
1. Intent. The -F, Flexible character designation is generally intended to allow the highest levels of flexibility in terms of allowed building types and development patterns.
2. Allowed Building Types. The following building types are permitted in -F character zones (see building type definitions in Section 35.010):
a. Vertical mixed-use and mixed-use buildings.
b. Commercial buildings.
c. Apartment/Condo.
d. Townhouses.
e. Duplexes.
f. Detached houses.
g. Civic/Institutional buildings.
h. Open space sites.
3. Lot and building regulations. The lot and building regulations of Table 10-7 apply to all new construction and building additions in -F character zones. General exceptions to lot and building regulations and rules for measuring compliance can be found in Chapter 90. Existing buildings are exempt from ground floor ceiling height and transparency requirements.
Table 10-7: Lot and Building Regulations for -F Character Zones
Minimum Lot Area (sq. ft.)
Townhouse | 1,600
Duplex | 5,000
Apartment/condo | 7,500
Other buildings | 3,300
Minimum Lot Width (feet)
Townhouse | 20
Duplex | 45
Apartment/condo | 50
Other buildings | 20
Minimum Street Frontage (feet) | 20
Minimum Open Space per Unit (sq. ft.)
Detached house | 400
Townhouse/Duplex | 200
Apartment/condo/mixed-use | 100
Minimum Building Setbacks (feet)
Detached house/townhouse/duplex
Street | 15[1]
Side | 3[2]
Rear | 20
Other buildings
Street | 5
Abutting R district | 10
Abutting alley | 5
Abutting nonresidential district | 0
Minimum Parking Setbacks (feet) (see also Subsection 55.080C.)
Detached house/townhouse/duplex | -
Other buildings [3]
Street | 10
Abutting R district | 10
Abutting nonresidential district | 0
Abutting alley | 2
Min. Ground Floor Ceiling Height (feet)
Vertical mixed-use, mixed-use and commercial buildings | 14
Other buildings | -
Minimum Transparency (%)
Vertical mixed-use buildings
Ground floor | 40
Upper floors | 20
Commercial buildings and mixed-use buildings
Ground floor | 35
Upper floors | 20
Other buildings | 20
Street-facing Entrance Required | Yes
[1] Garage doors must be set back at least twenty (20) feet from back of sidewalk (see Figure 10-7).
[2] For townhouses, side setback applies only to exterior wall of end units.
[3] Parking structures are subject to Section 40.280.
Figure 10-7: Garage Door Setback
[image omitted; see the official code]
(Ord. No. 24725, §§ 3—6, 11-17-2021; Ord. No. 25055, § 4, 5-24-2023; Ord. No. 25656, §§ 4—9, 9-10-2025)