Seattle Mun. Code ch. 25.10, subch. III, § 25.10.300 Radiofrequency radiation standards.
25.10.300 - Radiofrequency radiation standards.
A source of radiofrequency radiation, by itself or in combination with other sources of radiofrequency radiation, shall not expose the general population to ambient radiation that exceeds the root mean squared electric or magnetic field strength, or their equivalent plane-wave free-space power density as averaged over a six (6) minute period, for the frequency ranges and duration described in Table 25.10.300 A.
Table 25.10.300 A
Frequency (MHz) | Mean Squared Electric Field Strength (V2m2) | Mean Squared Magnetic Field Strength (A2/m2) | Equivalent Plane-wave Power Density (uW/cm2)
.1 to 3 | 80,000 | 0.5 | 20,000
3 to 30 | 4,000 | 0.025
(180/f 2 ) | (180/f 2 ) | 180,000/f 2
30 to 300 | 800 | 0.005 | 200
300 to 1,500 | 4,000 | 0.025
(f/1,500) | (f/1,500) | f/1.5
1,500 to 300,000 | 4,000 | 0.025 | 1,000
Note:
f = Frequency in megahertz (MHz);
V 2 /m 2 = Volts squared per square meter;
A 2 /m 2 = Amperes squared per square meter;
uW/cm 2 = Microwatts per square centimeter.
Compliance with the radiofrequency radiation standards is determined from spatial averages of power density or the mean squared electric and magnetic field strengths over a volume equivalent to the human body. The peak radiofrequency radiation levels shall not exceed twenty (20) times the allowed spatially averaged values at frequencies below three hundred (300) MHz, nor the equivalent power density of four thousand (4,000) uW/cm 2 for frequencies between three hundred (300) MHz and six thousand (6,000) MHz, (f/1.5) uW/cm 2 for frequencies between six thousand (6,000) MHz and thirty thousand (30,000) MHz, and twenty thousand (20,000) uW/cm 2 at frequencies above thirty thousand (30,000) MHz. This requirement may be met by measurement of the radiofrequency radiation level along a vertical line at intervals not exceeding twenty centimeters (20 cm) over the vertical extent of an individual and calculating the average value of the readings.
(Ord. 116057, § (part), 1992)