11.79.320 - Diatomaceous earth filters.

Diatomaceous earth filtration units are acceptable in swimming pool recirculation systems. The two types permitted are pressure and vacuum. Pressure Diatomaceous Earth Filters. A. Filter Area. Sufficient filter area must be provided to filter the entire contents of the pool in six (6) hours or less at the rate of not more than two (2) gallons per minute per square foot of filter area with continuous body feed or at the rate of not more than one and one-half (1½) gallons per minute per square foot without continuous body feed. B. Filter Elements. The filter element and septum shall be constructed and installed to adequately resist significant deformation, rupture or dislocation with the maximum differential pressure between influent and effluent developed by the pump during filtering and/or backwashing operation. C. Pre-coating. Provision shall be made to introduce a precoat of filter aid to evenly cover the filter elements upon placing the equipment into initial operation and after each cleaning. The amount of filter aid shall be selected to provide at least the same protection to the filter septum as that given by 0.1 pounds of diatomaceous earth filter aid per square foot of filter area where body feed is employed or 0.15 pounds per square foot where no body feet is used. The total required pre-coat material must be introduced into the filter within five (5) minutes of recirculation. D. Body or Slurry Feeding. Where provided, the body feeding equipment designed for feed of filter aid to the filter influent shall have a rate capacity to feed at a reasonable constant rate easily adjustable within a calibrated range of from (2) to ten (10) ppm of the gpm design rate of the filtering unit. (The equipment shall have capacity to operate at the maximum feed rate of ten (10) ppm of the design filter rate for a period of twenty-four (24) hours without refilling.) E. Backwash and Precoat. The filter piping may be installed to permit recirculation of the water from the effluent back to the influent until a satisfactory clear effluent backwashing and precoating is produced prior to admitting the water into the pool. An alternate is to discharge the unsatisfactory effluent to waste. F. Cleaning Elements. Sufficient head room and facilities must be provided in the filter room for periodic removal of the filter head and element assembly for manual cleaning purposes. G. Gauges. Pressure gauges must be installed on both the influent and effluent side of each pressure filter unit. Vacuum Diatomaceous Earth Filters. Vacuum diatomaceous earth filters shall be installed in accordance with all provisions set forth for pressure diatomaceous earth filters with the following additional requirements: A. Provision must be made for complete and rapid draining or emptying of the filter tank prior to and during backwashing. B. Easy physical and visual access to the filter elements must be provided to facilitate cleaning during the backwashing cycle. C. A spray nozzle system should be installed to wash and clean the surface of the filter septum. In lieu of this system, a hose bib with an adequate length of hose must be provided near the filter for this purpose. D. A compound gauge which will indicate both positive and negative head must be installed on the suction side of the pump. E. In systems where the recirculation pump is two (2) horse power or higher, an adjustable high vacuum switch should be provided to prevent damage to the pump by cavitation. Other types of filtration, including cartridge and high permeability type units, will be considered on an individual basis.

(1994 C., § 11.79.320; Ord. No. 65567, § 32, 2002.)

Ask a question about St. Louis law

Corpus searches the St. Louis sections it holds and shows the ones that match, with their citations. Free, no sign-in.