For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 17.38.070 — Frontage

Pasadena Municipal Code, California (Supp. No. 79: codified through Ordinance No. 7469, enacted May 18, 2026) · Pasadena Municipal Code § 17.38.070

Corpus is an independent public-information project, not the official City of Pasadena website. Stable reference: corpuslaw.us/code/78fe3561-e038-4fc9-888a-a3dd85796c52

17.38.070 - Frontage

These standards are intended to: • Promote an active, accessible, and attractive pedestrian environment at the ground level; • Activate the pedestrian street experience through design and use standards; • Enable flexibility and adaptability over time through quality design; and • Support a livable urban setting comprised of a range of uses in a comfortable pedestrian environment. A. Ground Floor Frontages In Mixed-Use zoning districts, ground floor use requirements are regulated by frontage type per Figure LPSP-18 and Table LPSP-5. All use requirements are regulated as a percentage of the building frontage. 1. Commercial Uses. Frontage types require a minimum percent of the building frontage to be comprised of, and designed for, commercial uses per Figure LPSP-18 and Table LPSP-5; see Figure LPSP-19. Permitted commercial uses by zoning district are found in Table LPSP-1. a. Entrances to non-ground floor uses, and/or entrances to uses prohibited within 35 feet of the sidewalk, shall not qualify toward the minimum commercial use percentage. b. Commercial uses shall have an average interior depth of at least 35 feet and a minimum depth of 20 feet, measured wall-to-wall. 2. Residential Uses. Frontage types set limitations on ground floor residential uses facing the street per Figure LPSP-18 and Table LPSP-5. Permitted residential uses by zoning district are found in Table LPSP-1. a. Types 1, 2: Residential units on the ground floor shall be prohibited within 35 feet of the sidewalk line, inclusive of setbacks, per Table LPSP-5; see Figure LPSP-20. b. Type 3: Residential units on the ground floor shall be permitted with direct access to the street and a minimum setback of 5 feet. c. Residential common space on the ground floor shall be permitted per Table LPSP-5. Figure LPSP-18: Ground Floor Frontage Types [image omitted; see the official code] Table LPSP-5: Allowable Ground Floor Building Frontages in Mixed-Use Zones Type | Commercial Uses | Residential Common Space | Residential Dwelling Units 1 | 80% min. | 20% max. | Prohibited within 35' of sidewalk line 2 | Allowed, no percentage requirements 3 | Allowed, no percentage requirements Figure LPSP-19: Ground Floor Commercial Uses [image omitted; see the official code] Figure LPSP-20: Ground Floor Residential Units [image omitted; see the official code] B. Ground Floor Design 1. Entrances. A minimum of one primary entrance shall be located on the primary frontage within the setback range, connected by a pedestrian pathway a minimum of 4 feet in width that leads directly to the sidewalk. a. Primary entrances shall be distinguished by architectural features or overhead projections, such as an awning or canopy. b. On sites with frontages on both Foothill Boulevard and Walnut Street, projects shall provide pedestrian pathways on both frontages. c. All entrances shall be recessed a minimum of 30 inches from the sidewalk line. 2. Minimum Height. Buildings shall have a minimum ground floor height of 12 feet, except those facing Colorado Boulevard, Foothill Boulevard, Sierra Madre Boulevard or Walnut Street, which shall have a minimum ground floor height of 15 feet. This height is measured from sidewalk elevation closest to the primary entrance to the second story floor or roof of a one-story building; see Figure LPSP-21. a. For residential units, the first habitable floor shall be located between 6 feet above and 2 feet below sidewalk elevation. b. For non-residential and residential common space uses, the primary entrance of the first habitable floor shall be located at existing grade along the sidewalk line. (1) Exception: In CF, the primary entrance of the first habitable floor shall be located between 4 feet above and 2 feet below sidewalk elevation. Figure LPSP-21: Ground Floor Height [image omitted; see the official code] C. Transparency 1. Windows & Doors. Street-facing façades shall incorporate glass providing views into work, display, sales, lobby, or similar active areas. The minimum transparency requirement is set in Table LPSP-6. a. For non-residential and residential common space uses, ground floor transparency is measured as the percentage of building frontage that consists of transparent openings between a height of 2 feet and 10 feet above sidewalk elevation. b. Overall façade transparency is measured as the percentage of building frontage area, viewed in elevation and excluding any coverage of shading devices. c. Windows shall be recessed a minimum of 2 inches, measured from the outside wall to the frame of the window (mullion, muntin or similar element). Flush windows shall be permitted where exterior shading devices cover a minimum of 25 percent of the window surface area or per review authority approval. d. The use of tinted, mirrored, or highly reflective glass is prohibited. e. Street-facing transparency that is obstructed by walls or fences taller than 42 inches will not be counted toward the required transparency; see Figure LPSP-22. f. Blinds, drapes, posters, and shelving for product displays visible to the public right-of-way shall obscure a maximum of 10 percent of the transparent areas of each respective storefront or 50 percent for medical office uses. Figure LPSP-22: Fences, Walls, and Transparency [image omitted; see the official code] Table LPSP-6: Minimum Transparency by Use Type | Non-residential, Mixed-Use and Residential Common Space | Residential Units CF | MU-G | MU-N | CF | MU-G | MU-N Ground Floor | 30% | 60% | N/A | 15% Overall Façade | 15% | 30% | N/A | 15% 2. Blank Façades. Windowless expanses of street-facing façades shall not exceed 20 feet in length. a. Exception: In CF zoning districts, windowless expanses of street-façades shall not exceed 40 feet in length. Blank façades shall include a minimum of one 24-inch box tree for every 15 linear feet of blank façades, except where public art (e.g., a mural) is provided per Section 17.40.100 (Public Art Requirements and Design Standards). 3. Security Bars. Any exterior or interior security bars shall be designed to be fully hidden from view during business hours with devices such as concealed side pockets and ceiling cavities. D. Shade Structures 1. Awnings & Canopies. Any ground floor shading shall project a minimum of 3 feet from the façade and allow a minimum of 8 feet of vertical clearance from sidewalk elevation. a. Shade structures shall not conflict with existing trees; exceptions to the depth requirement to accommodate existing trees shall be subject to review authority approval. 2. Colorado Boulevard. For projects on the north side of Colorado Boulevard, shade structures are required and shall project a minimum of 7 feet, up to a maximum of 10 feet, into the public right-of-way for a minimum of 70 percent of the building frontage. a. Where an arcade or recessed ground floor provides a minimum of 5 feet of unobstructed pedestrian clearance, shade structures are not required. E. Arcades & Galleries 1. Arcades. Any arcades shall be located behind the minimum setback. a. Arcades shall be a minimum of 8 feet from back of column to building façade. b. The distance between columns shall be equal to or greater than the arcade depth dimension, as measured from the column center. c. The façade within the arcade shall meet the ground floor transparency set in Section 17.38.070.C. d. Uses allowed within arcades include: pedestrian travel, seating/street furniture, outdoor dining, landscape planters, and/or bicycle parking. 2. Galleries. Any galleries shall be located behind the minimum setback. a. Galleries shall be limited to one-story in height and 50 percent of the building frontage. b. Galleries shall allow a minimum of 10 feet of vertical clearance from sidewalk elevation. F. Exterior Fixtures 1. Ground Floor Façade Lighting. Lighting shall be located on façades facing streets and public open spaces at a frequency of every 30 feet or less. a. Lighting shall be full cutoff (directing light downward and outward). b. Fixtures shall be located between 8 and 15 feet above sidewalk elevation and shall not project more than 30 inches from the façade. c. Ground floor residential units shall be able to operate façade lighting attached directly to their unit. d. Façade lighting shall not be required on designated historic resources and districts. G. Walls & Fences 1. Walls & Fences. Freestanding walls, fences, and raised/landscape planters shall be permitted within the required street setback. a. Walls and fences shall have a maximum height of 48 inches above sidewalk elevation. (1) Exception: In CF, walls and fences shall have a maximum height of 72 inches above the sidewalk elevation. Walls and fences over 48 inches in height shall be set back a minimum of 5 feet from the sidewalk line, separated by planted area. (2) In MU-G and MU-N, walls and fences taller than 42 inches shall be a minimum of 50 percent transparent and set back a minimum of 18 inches from the sidewalk line, separated by planted area. Walls and fences 42 inches or less in height do not have a transparency or setback requirement. b. Wall and fences shall not block required transparency per Section 17.38.070.C.1 or murals per Section 17.38.070.C.2. c. Walls and fences used to enclose outdoor dining may be located at the sidewalk line and are not required to provide a planted area if the wall or fence is 36 inches or less and more than 50 percent transparent. d. Guardrails may exceed the maximum height to the extent required by the Building Code. The guardrail shall be a minimum of 50 percent transparent. 2. Stoops & Patios. The side of a patio or stoop (when parallel to a sidewalk) taller than 30 inches in height shall be set back a minimum of 18 inches from the sidewalk line, separated by planted area. H. Balconies & Roof Decks 1. Balconies. Balconies may project a maximum of 4 feet from the building façade but shall not extend beyond the sidewalk line or within 6 feet of any interior property line. 2. Roof Decks. The sum of all roof decks on a single building shall not exceed a maximum coverage of 60 percent of the roof area. a. Roof deck railings above the top floor shall be placed behind a parapet wall of at least the same height or shall be set back a minimum of 5 feet from the façade.

(Ord. No. 7446, § 3, 5-12-2025)

Ask a question about Pasadena law

Corpus searches the Pasadena sections it holds and shows the ones that match, with their citations. Free, no sign-in.