(a) The design filtration rate of rapid sand filters must not exceed three gallons per minute per square foot of filter area. High-rate sand filters must not exceed a filtration rate of 15 gallons per minute per square foot. Higher rates may be used if the filter has been successfully tested against NSF/ANSI Standard 50 at the higher rate. The sand filter system must be equipped to backwash each filter at a rate of 15 gallons per minute per square foot of filter bed area, or as recommended by the manufacturer. A flow meter or other device which gives a continuous indication of the flow rate in gallons per minute to indicate the backwash rate for rapid sand filters must be provided. The backwash water must be discharged to waste through a suitable air gap. (b) In the complete filter installation, where dissimilar metals are used which may set up galvanic electric currents, the metals shall be separated with a suitable dielectric which will satisfactorily prevent electrolysis. (c) The filter bed shall consist of suitable grades of filter sand and a supporting bed of graded gravel or other porous material which shall serve to support the filter bed and distribute both filtered and backwash water uniformly. The supporting bed consisting of graded gravel or other material shall support not less than 20 inches of filter media consisting of silica sand or other durable, inert material with an effective size between four-tenths and fifty-five hundredths mm, and a uniformity coefficient not exceeding one and seventy-five hundredths. (d) The minimum freeboard to the draw-off point shall be not less than 12 inches above the normal level of the top of the filter bed. The minimum backwash rate shall be not less than 15 gallons per square foot of filter bed per minute. A backwash rate of 20 gallons per square foot and 18 inches of freeboard is recommended. (e) Where anthracite coat or other filter media is employed, the freeboard shall be adequate to prevent the media being carried off to waste when the filter bed is backwashed at a rate adequate to carry off foreign material filtered from the water. The freeboard and the rate of backwash shall be the subject of individual design, based upon specific gravity of the media. (f) The under-drain system shall be such that uniform distribution of backwash water shall be provided over the entire bed area. (g) The under-drain system shall be fabricated of material which is corrosion-resistant and enduring, wherein the orifices shall be so designed and of such material that they will maintain an approximately constant area. (h) The filter plant shall be provided with proper and adequate controls such as: (1) Air relief valves. (2) Backwash indicators or controllers. (3) Backwash sight glasses. (4) Loss of head gauges. (5) Rate of flow indicators or controllers. (6) Sampling cocks. (7) Valves and piping to regulate flow of water to and from filters for proper filtration and for backwash to waste. (i) The filter plant shall be provided with means for draining all filter units and piping, so that all parts of the system may be completely drained to prevent damage from freezing. (j) Each pressure filter unit shall be provided with an access opening of not less than a standard 11-inch by 15-inch manhole and cover. (k) Filter wash water may create nuisance conditions if not properly handled. New pools must discharge filter backwash and filter waste water to a sanitary sewer system if available. As an alternate, settling, decantation of supernatant, drying and disposal of sludge may be necessary. Determination and DCHD approval of waste water disposal should be made early in the planning process to permit flexibility in pool layout and site utilization.
(Code 1980, § 54-107; Ord. No. 37382, § 36, 5-23-06)
Ask a question about Omaha law
Corpus searches the Omaha sections it holds and shows the ones that match, with their citations. Free, no sign-in.