For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 8-8 — Restriction of emission of volatile organic compounds

Code of Ordinances of Kansas City, Missouri (Supp. No. 140, Update 1: codified through Ordinance No. 260692, enacted August 13, 2026) · Kansas City Code § 8-8

Corpus is an independent public-information project, not the official City of Kansas City website. Stable reference: corpuslaw.us/code/7d036d23-69a5-45b3-8f54-687576f0c743

Sec. 8-8. - Restriction of emission of volatile organic compounds.

The purpose of this section is to reduce volatile organic compound (VOC) emissions in the ambient air. (1) Restriction of emission of VOC from solvent metal cleaning. a. This section applies to all installation which emits volatile organic compounds (VOC) from solvent metal cleaning or degreasing operations. b. This subsection applies to any of the following processes that use nonaqueous solvents to clean and remove soils for metal parts: 1. Cold cleaners with a solvent reservoir or tanks; 2. Open-top vapor or conveyorized degreasers; 3. Air-tight or airless cleaning systems; or 4. Spray gun cleaners. (2) General provisions. a. No person shall cause or allow a solvent metal cleaning or degreasing operation: 1. Without operating procedures as contained in this subsection and recommendations by the equipment manufacturer; 2. Without the minimum operator and supervisor training. 3. Unless the equipment conforms to the specifications listed in this subsection. b. The owner or operator of a solvent metal cleaning or degreasing operation shall keep monthly inventory records of solvent types and amounts purchased and solvent consumed for a period of two years. These records shall include all types and amounts of solvent containing waste material transferred to either a contract reclamation service or to a disposal facility and all amounts distilled on the premises. The records also shall include maintenance and repair logs for both the degreaser and any associated control equipment. The director may require further recordkeeping if necessary to adequately demonstrate compliance with this subsection. All these records shall be made available to the director upon their request. (3) Exemptions. a. The following shall be exempt from this subsection: 1. Cold cleaners with liquid surface areas of one square foot or less or maximum capacities of one gallon or less; 2. Solvent cleaning operations regulated under 40 CFR 63 Subpart T, National Emission Standards for Halogenated Solvent Cleaning. The provisions of 40 CFR part 63 subpart T promulgated as of December 19, 2005 shall apply and are hereby incorporated by reference in this subsection, as published by the U.S. Government Printing Office, 732 N Capitol Street NW, Washington, DC 20401. 3. The cleaning of electronic components, medical devices or optical devices; 4. Hand cleaning/wiping operations; 5. Flush cleaning operations; b. The following shall be exempt from the solvent vapor pressure requirements of subparagraphs (E)1.(a) and (E)1.(b) of this subsection: (a) Sales of cold cleaning solvents in quantities of five gallons or less; (b) Cold cleaners using solvents regulated under any federal National Emission Standards for Hazardous Air Pollutants; and (c) Janitorial and institutional cleaning. (4) Equipment specifications. a. Cold cleaners. 1. No one shall use, sell or offer for sale for use a cold cleaning solvent with a vapor pressure greater than 1.0 mmHg (0.019 psi) at 20 degrees Celsius (68 degrees Fahrenheit) unless used for carburetor cleaning. 2. No one shall use, sell or offer for sale for use a cold cleaning solvent for the purpose of carburetor cleaning with a vapor pressure greater than 5.0 mmHg (0.097 psi) at 20 degrees Celsius (68 degrees Fahrenheit). 3. An owner or operator of a cold cleaner may use an alternate method for reducing cold cleaning emissions if the owner or operator shows the level of emission control is equivalent to or greater than the requirements of subparagraphs paragraphs (E)1.(a) and (E)1.(b) of this subsection. This alternate method must be approved by the director and the U.S. Environmental Protection Agency (EPA). 4. Each cold cleaner shall have a cover which will prevent the escape of solvent vapors from the solvent bath while in the closed position or an enclosed reservoir which will limit the escape of solvent vapors from the solvent bath whenever parts are not being processed in the cleaner. 5. When one or more of the following conditions exist, the cover shall be designed to operate easily such that minimal disturbing of the solvent vapors in the tank occurs. For covers larger than ten square feet, this shall be accomplished by either mechanical assistance such as spring loading or counter weighing or by power systems: i. The solvent vapor pressure is greater 0.3 psi measured at 37.8 degrees Celsius (100 degrees Fahrenheit); ii. The solvent is agitated; or iii. The solvent is heated. 6. Each cold cleaner shall have an internal drainage facility that parts are enclosed under the cover while draining. 7. If an internal drainage facility cannot fit into the cleaning system and the solvent vapor pressure is less than 0.6 pounds per square inch measured at 37.8 degrees Celsius (100 degrees Fahrenheit), then the cold cleaner shall have an external drainage facility which provides for the solvent to drain back into the solvent bath. 8. Solvent sprays, if used, shall be a solid fluid stream (not a fine, atomized or shower-type spray) and at a pressure which does not cause splashing above or beyond the freeboard. 9. A permanent conspicuous label summarizing the operating procedures shall be affixed to the equipment or in a location readily visible during operation of the equipment. 10. Any cold cleaner which uses a solvent that has a solvent vapor pressure greater than 0.6 pounds per square inch psi measured at 37.8 degrees Celsius (100 degrees Fahrenheit) or heated above 48.9 degrees Celsius (120 degrees Fahrenheit) must use one of the following control devices: i. A freeboard ratio greater than or equal to 0.75; ii. Water cover (solvent must be insoluble and heavier than water); or iii. Other control systems with a mass balance demonstrated overall VOC emissions reduction efficiency greater than or equal to 65 percent. These control systems must receive approval from the director and EPA prior to their use. b. Open-top vapor degreasers (a) Each open-top vapor degreaser shall have a cover which will prevent the escape of solvent vapors from the degreaser while in the closed position and shall be designed to open and close easily such that minimal disturbing of the solvent vapors in the tank occurs. For covers larger than ten square feet, easy cover use shall be accomplished by either mechanical assistance such as spring loading or counter weighing or by power systems. (b) Each open-top vapor degreaser shall be equipped with a vapor level control device that shuts off the heating source when the vapor level rises above the cooling or condensing coil, or an equivalent safety device approved by the director and EPA. (c) Each open-top vapor degreaser with an air/vapor interface over 10¾ square feet shall be equipped with at least one of the following control devices: i. A freeboard ratio of at least 0.75; ii. A refrigerated chiller; iii. An enclosed design (the cover or door opens only when the dry part is actually entering or exiting the degreaser); iv. A carbon adsorption system with ventilation of at least 50 cubic feet per minute per square foot of air vapor area when the cover is open, and exhausting less than 25 parts per million of solvent by volume averaged over one complete adsorption cycle as measured using 40 CFR part 60, appendix A—Test Methods, "Method 25—Determination of Total Gaseous Nonmethane Organic Emissions as Carbon;" or v. A control system with a mass balance demonstrated overall VOC emissions reduction efficiency greater than or equal to 65 percent and prior approval by the director and EPA. (d) A permanent conspicuous label summarizing the operating procedures shall be affixed to the equipment or in a location readily visible during operation of the equipment. c. Conveyorized degreasers. (a) Each conveyorized degreaser shall have a drying tunnel or rotating (tumbling) basket or other means demonstrated to have equal to or better control which shall be used to prevent cleaned parts from carrying out solvent liquid or vapor. (b) Each conveyorized degreaser shall have the following safety devices which operate if the machine malfunctions: i. A vapor level control device that shuts off the heating source when the vapor level rises just above the cooling or condensing coil; and ii. A spray safety switch, which shuts off the spray pump if the vapor level in the spray chamber drops four inches, for conveyorized degreasers utilizing a spray chamber. iii. Equivalent safety devices approved by the director and EPA. (c) Entrances and exits shall silhouette workloads so that the average clearance between parts and the edge of the degreaser opening is less than four inches or less than ten percent of the width of the opening. (d) Covers shall be provided for closing off the entrance and exit during hours when the degreaser is being used. (e) A permanent conspicuous label summarizing the operating procedures shall be affixed to the equipment or in a location readily visible during operation of the equipment. (f) If the air-vapor interface is larger than 21.5 square feet, one major control device shall be required. This device shall be one of the following: i. A refrigerated chiller; ii. Carbon adsorption system with ventilation of at least 50 cubic feet per minute per square foot of the total entrance and exit areas (when downtime covers are open), and exhausting less than 25 parts per million of solvent by volume averaged over one complete adsorption cycle as measured using the reference method as specified in 40 CFR 60 appendix A—Test Methods "Method 25—Determination of Total Gaseous Nonmethane Organic Emissions as Carbon;" or iii. A control system with a mass balance demonstrated overall VOC emissions reduction efficiency greater than or equal to 65 percent and prior approval by the director. d. Air-tight or airless cleaning systems. (a) Have a permanent conspicuous label summarizing the operating procedures affixed to the equipment or in a location readily visible during operation of equipment; (b) Be equipped with a differential pressure gauge to indicate the sealed chamber pressure under vacuum; (c) Be equipped with a safety alarm to alert the operator of equipment malfunction. (5) Operating procedure requirement. a. Cold cleaners. 1. Cold cleaner covers shall be closed whenever parts are not being handled in the cleaners or the solvent must drain into an enclosed reservoir except when performing maintenance or collecting solvent samples. 2. Cleaned parts shall be drained in the freeboard area for at least 15 seconds or until dripping ceases, whichever is longer. Parts having cavities or blind holes shall be tipped or rotated while the part is draining. During the draining, tipping, or rotating, the parts shall be positioned so that the solvent drains directly back into the cold cleaner. 3. Whenever a cold cleaner fails to perform within the rule operating requirements, the unit shall be shut down immediately and shall remain shut down until operation is restored to meet rule operating requirements. 4. Solvent leaks shall be repaired immediately or the cold cleaner shall be shut down until the leaks are repaired. 5. Any waste material removed from a cold cleaner shall be disposed of by one of the following methods or an equivalent method approved by the director and EPA: i. Reduction of the waste material to less than 20 percent VOC solvent by distillation and proper disposal of the still bottom waste; or ii. Stored in closed containers for transfer to: a. A contract reclamation service; or b. A disposal facility approved by the director and EPA. 6. Waste solvent shall be stored in closed containers only. b. Open-top vapor degreasers. (a) The cover shall be kept closed at all times except when processing workloads through the open-top vapor degreaser, performing maintenance or collecting solvent samples. (b) Solvent carry-out shall be minimized in the following ways: i. Parts shall be racked, if practical, to allow full drainage; ii. Parts shall be moved in and out of the open-top vapor degreaser at less than 11 feet per minute; iii. Workload shall remain in the vapor zone at least 30 seconds or until condensation ceases, whichever is longer; iv. Pools of solvent shall be removed from cleaned parts before removing parts from the open-top vapor degreaser freeboard area; and v. Cleaned parts shall be allowed to dry within the open-top vapor degreaser freeboard area for at least 15 seconds or until visually dry, whichever is longer. (c) Porous or absorbent materials such as cloth, leather, wood or rope shall not be degreased. (d) If workloads occupy more than half of the open-top vapor degreaser's open-top area, rate of entry and removal shall not exceed five feet per minute. (e) Spray shall never extend above vapor level. (f) Whenever an open-top vapor degreaser fails to perform within the rule operating requirements, the unit shall be shut down until operation is restored to meet the rule operating requirements. (g) Solvent leaks shall be repaired immediately or the open-top vapor degreaser shall be shut down until the leaks are repaired. (h) Ventilation exhaust from the open top vapor degreaser shall not exceed 65 cubic feet per minute per square foot of open-top vapor degreaser open area unless proof is submitted that it is necessary to meet Occupational Safety and Health Administration (OSHA) requirements. Fans shall not be used near the open-top vapor degreaser opening. (i) Water shall not be visually detectable in solvent exiting the water separator, except for automatic water separators that by configuration do not allow visual inspection. (j) Any waste material removed from an open-top vapor degreaser shall be disposed of by one of the following methods or an equivalent method approved by the director and EPA: i. Reduction of the waste material to less than 20 percent VOC solvent by distillation and proper disposal of the still bottom waste; or ii. Stored in closed containers for transfer to: a. A contract reclamation service; or b. A disposal facility approved by the director and EPA. (k) Waste solvent shall be stored in closed containers only. c. Conveyorized degreasers. (a) Ventilation exhaust from the conveyorized degreaser shall not exceed 65 cubic feet per minute per square foot of conveyorized degreaser opening unless proof is submitted that it is necessary to meet OSHA requirements. Fans shall not be used near the conveyorized degreaser opening. (b) Solvent carry-out shall be minimized in the following ways: i. Parts shall be racked, if practical, to allow full drainage; and ii. Vertical conveyor speed shall be maintained at less than 11 feet per minute. (c) Whenever a conveyorized degreaser fails to perform within the rule operating requirements, the unit shall be shut down immediately and shall remain shut down until operation is restored to meet the rule operating requirements. (d) Solvent leaks shall be repaired immediately or the conveyorized degreaser shall be shut down until the leaks are repaired. (e) Water shall not be visually detectable in solvent exiting the water separator. (f) Covers shall be placed over entrances and exits immediately after conveyor and exhaust are shut down and removed just before they are started up. (g) Waste solvent shall be stored in closed containers only. (h) Any waste material removed from a conveyorized degreaser shall be disposed of by one of the following methods or an equivalent method approved by the director and EPA: i. Reduction of the waste material to less than 20 percent VOC solvent by distillation and proper disposal of the still bottom waste; or ii. Stored in closed containers for transfer to: a. A contract reclamation service; or b. A disposal facility approved by the director and EPA. d. Spray gun cleaners. 1. Cleaning of spray guns shall be accomplished by use of one or more of the following methods: i. Enclosed spray gun cleaning. Enclosed system spray gun cleaning shall consist of forcing solvent through the spray gun and/or spray gun parts. Spray guns and/or spray gun parts shall only be cleaned in remote closed top spray gun cleaning machines under the following conditions: a. The spray gun cleaning machine is operated within the manufacturer's specifications and with the lid kept tightly closed at all times except when being accessed or maintained; and b. Removable containers (which shall not exceed 30 gallons in size) for clean, used and waste solvent, are kept tightly closed except when being accessed or maintained; ii. Nonatomized spray gun cleaning. Nonatomized spray gun cleaning shall consist of placing solvent in the pressure pot and forcing it through the spray gun with the atomizing cap in place. Spray guns shall only be cleaned through nonatomized spray gun cleaning under the following conditions: a. No atomizing air shall be used; and b. The cleaning solvent from the spray gun shall be directed into a pail, bucket, drum or other waste container that is closed when not in use; iii. Disassembled spray gun cleaning. Disassembled spray gun cleaning shall be accomplished by disassembling the spray gun to be cleaned and cleaning the components by one of the following methods: a. By hand in a spray gun cleaner, which shall remain closed except when in use; or b. By soaking in a spray gun cleaner, which shall remain closed during the soaking period and when not inserting or removing components; iv. Atomized spray gun cleaning. Atomized spray gun cleaning shall consist of forcing the cleaning solvent through the gun and directing the resulting atomized spray into a waste container that is fitted with a device designed to capture the atomized cleaning solvent emissions; or v. Cleaning of the nozzle tips of an automated spray equipment system is exempt from the requirements of point (F)4. of this subsection, unless the system is a robotic system that is programmed to spray into a closed container. 2. Any waste material removed from a spray gun cleaning system shall be disposed of by one of the following methods or an equivalent method approved by the director and EPA: i. Reduction of the waste material to less than 20 percent VOC solvent by distillation and proper disposal of the still bottom waste; or ii. Stored in closed containers for transfer to: a. A contract reclamation service; or b. A disposal facility approved by the director and EPA. 3. Waste solvent shall be stored in closed containers only. e. Air-tight and airless cleaning systems. (a) Operate the air-tight and airless cleaning systems with a door or other pressure sealing apparatus in place during all cleaning and drying cycles. (b) All associated pressure relief devices shall not allow liquid solvent to drain out of the equipment. (c) Solvent leaks shall be repaired immediately or the air-tight or airless cleaning system shall be shut down until the leaks are repaired. (d) The air-tight and airless cleaning systems shall be operated within the manufacturer's specifications. (e) Parts shall be positioned, if practical, to allow full drainage and pools of solvent shall be removed from cleaned parts before removing parts from the air-tight or airless cleaning system. (f) Wipe up solvent leaks and spills immediately and store the used rags in closed containers. (g) Any waste material removed from an air-tight and airless cleaning system shall be disposed of by one of the following methods or an equivalent method approved by: (I) Reduction of the waste material to less than 20 percent VOC solvent by distillation and proper disposal of the still bottom waste; or (II) Stored in closed containers for transfer to: a. A contract reclamation service; or b. A disposal facility approved by the director and EPA. (h) Waste solvent shall be stored in closed containers only. (6) Operator and supervisor training. 1. Only persons trained in at least the operational and equipment requirements specified in this subsection for their particular solvent metal cleaning process shall be permitted to operate the equipment. 2. The supervisor of any person who operates a solvent metal cleaning process shall receive equal or greater operational training than the operator. 3. A procedural review shall be given to all solvent metal cleaning equipment operators at least once each 12 months. 4. A record shall be kept of solvent metal cleaning training for each employee. 5. Training records shall be maintained per subsections (H)4. and (H)5. of this subsection. (7) Reporting and record keeping. 1. The owner or operator of a solvent metal cleaning or degreasing operation shall keep records of all types and amounts of solvent containing waste material from cleaning or degreasing operations transferred to either a contract reclamation service or to a disposal facility and all amounts distilled on the premises. The records also shall include maintenance and repair logs for both the degreaser and any associated control equipment. These records shall be kept current and made available for review on a monthly basis. The director may require additional record keeping if necessary to adequately demonstrate compliance with this rule. 2. All persons that use any solvent subject to the requirements of subparagraphs (E)1.(a) or (E)1.(b) of this subsection shall maintain records which include for each purchase of cold cleaning solvent: (a) The name and address of the solvent supplier; (b) The date of purchase; (c) The type of solvent; and (d) The vapor pressure of the solvent in mmHg at 20 degrees Celsius (68 degrees Fahrenheit). 3. All persons that sell or offer for sale any solvent subject to the requirements of subparagraph (E)1.(a) or (E) 1.(b) of this subsection shall maintain records which include for each sale of cold cleaning solvent: (a) The name and address of the solvent purchaser; (b) The date of sale; (c) The type of solvent; (d) The unit volume of solvent; (e) The total volume of solvent; and (f) The vapor pressure of the solvent measured in mmHg at 20 degrees Celsius (68 degrees Fahrenheit). 4. A record shall be kept of solvent metal cleaning training required by point (G) of this subsection. 5. All records required under points (H)1., (H)2., and (H)3. of this section shall be retained for five years and shall be made available to the director upon request. (8) Restriction of emission of VOC from liquefied cutback asphalt paving. The purpose of this section is to restrict volatile organic compounds emissions from cutback asphalt paving operations. (A) This subsection limits the use or application of liquefied cutback asphalt in paving and maintenance operations of highways, roads, parking lots and driveways. (B) After December 31, 1982 no person may cause or permit the use or application of liquefied cutback asphalts on highways, roads, parking lots and driveways during the months of April, May, June, July, August, September and October except as permitted in paragraph (C). This subsection 8-8(2) refers to liquefied cutback asphalt which is directly applied or used in a plant-mix or road-mix. (C) Exceptions. The use or application of liquefied cutback asphalts is permitted if the liquefied cutback asphalt is: 1. Used in a plant-mix or road-mix which is used solely for filling potholes or for emergency repairs; 2. Used to produce a plant-mix manufactured for resale or for use outside Clay, Jackson and Platte Counties; or 3. To be used solely as asphalt prime coat or asphalt seal coat on absorbent surfaces. (D) Record keeping. 1. Records shall be kept on all application uses and all production quantities sufficient to determine daily volatile organic compound emissions for the months of April, May, June, July, August, September, and October. 2. Liquefied cutback asphalt plants shall keep records of the quantities of liquefied cutback asphalt sold and who the purchasers are. The owner, operator or user shall record all information derived for a period of not less than two years and all those records shall be made available to the director upon their request. (9) Restriction of emission of VOC from industrial surface coating operations. a. This rule restricts volatile organic compound emissions from industrial surface coating operations. 1. This subsection shall apply to any installation with an uncontrolled potential to emit greater than 6.8 kilograms per day (kg/day) or 2.7 tons per year of volatile organic compounds (VOC) from industrial surface coating operations covered under this subsection. This includes any installation which does not have an allowable VOC emission limit established under construction permit requirement or legally enforceable state implementation plan revision and has uncontrolled potential emissions greater than or equal to 6.8 kg/day or 2.7 tons per year. The uncontrolled potential to emit is the potential emissions (as defined) plus the VOC removed by emission control devices. 2. This section is not applicable of the surface coating of the following metal parts and products: (a) Exterior refinishing of airplanes; (b) Automobile refinishing; (c) Customizing top coating of automobiles and trucks, if production is less than 35 vehicles per day; and (d) Exterior of marine vessels. b. General provisions. No person shall emit into the atmosphere any VOC from any surface coating operation in excess of the amount allowed in point (C). This subsection will apply to application areas, flash-off areas and ovens used in an affected coating operation. c. Tables of emission limitations and dates of compliance. _____ 1. Table A: VOC Emission Limits Based on Solids Applied. Operations | Emission Limit #VOC/gal Solids Applied | Dates of Compliance (See Note 1) Auto/light duty truck *Ford Motor Company Primer surfacer | 15.1 | 12/24/1987 Topcoat (passenger) | 15.1 | 12/31/1988 Topcoat (truck) See Note 2 | 15.1 | 12/31/1988 General Motors Car Primer surfacer | 15.1 | 12/31/1987 Topcoat | 15.1 | 12/31/1987 2. Table B: VOC Emissions Limits Based on Weight of VOC per Gallon of Coating (minus Water and non-VOC organic compounds. Surface Coating Operations | Emission Limit VOC/gal Coating (minus water) and non-VOC Organic Compounds | Dates of Solids Compliance (See Note 1) Large appliance *Topcoat | 2.8 | 12/31/1981 Final repair | 6.5 | 12/31/1981 Magnet wire | 1.7 | 12/31/1981 Metal furniture | 3 | 12/31/1981 Auto/light duty truck Ford Motor Company Electrocoat prime | 1.2 | 12/31/1982 Topcoat (truck) | 3.6 | 12/31/1985 Topcoat (passenger) | 3.6 | 12/31/1986 Final repair | 4.8 | 12/31/1985 Miscellaneous metal parts-extreme performance and air-dried coatings | 3.5 | 12/31/1982 All other coatings | 3 | 12/31/1982 General Motors Car Cathodic electrocoat | 1.2 | 12/31/1982 Primer surfacer | 3 | 12/31/1980 Topcoat | 5.8 | 12/31/1979 5 | 12/31/1981 Final repair | 6.5 | 7/1/1979 4.8 | 12/31/1987 Plastic fascia topcoat | 4.5 | 11/23/1987 Miscellaneous metal parts-extreme performance and air-dried coatings | 3.5 | 12/31/1982 All other coatings | 3 | 12/31/1982 Paper | 2.9 | 12/31/1981 Vinyl | 3.8 | 12/31/1981 Fabric | 2.9 | 12/31/1981 Coil | 2.6 | 12/31/1981 Can 2 piece exterior | 4 | 12/31/1982 sheet basecoat | 2.8 | 12/31/1985 2 and 3 piece interior body spray | 4.2 | 12/31/1982 2 piece end exterior | 4.2 | 12/31/1982 3 piece side seam | 5.5 | 12/31/1982 End seal compound | 4.2 | 12/31/1982 3.7 | 12/31/1985 Railroad cars, farm Implements, machinery and heavy duty tracks | 3.5 | 12/31/1982 Other metal parts Clear coat | 4.3 | 12/31/1982 Extreme performance coat and air-dried coating | 3.5 | 12/31/1982 Other coatings | 3 | 12/31/1982 Note 1: The emission limit associated with the latest compliance date for each surface coating process supersedes interim emission limits associated with earlier compliance dates. Note 2: A formal commitment submitted to and received by the director prior to 12/13/88 to construct or modify the truck topcoat surface coating operation no later than 12/13/90 to meet the provisions of 10 CSR 10-6.070 or 40 CFR 60 Subpart MM, whichever is more stringent, may be substituted for this emission limitation. The emission limit specified by the rules referenced in this note is 12.3 lbs. VOC per gallon of solids applied. d. Determination of compliance. Compliance with subsection (c) shall be determined by the methods in subsections (5)1. through 3. as applicable and appropriate. 1. For subsection (C)1., the calculation of daily volume-weighted emission performance for automobile and light-duty truck primer-surfacer and topcoat operations, shall be made according to procedures detailed in the Environmental Protection Agency (EPA) document entitled Protocol for Determining the Daily Volatile Organic Compound Emission Rate for Automobile and Light Duty Truck Topcoat Operations dated June 10, 1988. 2. For subsection (C)2.: A. Compliance with emission limits may be demonstrated using the method as specified in 40 CFR 60, appendix A—Test Methods, "Method 24—Determination of Volatile Matter Content, Water Content, Density, Volume, Solids and Weight Solids of Surface Coatings," using the one-hour bake. Emission performance shall be on the basis of a daily volume-weighted average of all coatings used in each surface coating operation as delivered to the coating applicator(s) on a coating line. The daily volume-weighted average (DAVG vw ) is calculated by the following formula: [image omitted; see the official code] Where: A = Daily gal. each coating used (minus water and exempt solvents) in a surface coating operation. B = Lbs. VOC/gal coating (minus water and exempt solvents). C = Total daily gal. coating used (minus water and exempt solvents) in a surface coating operation. n = Number of all coating used in a surface coating operation. B. Compliance with the emission limits in subsection (c)2. may be demonstrated on pounds of VOC per gallon of coating solids basis. The demonstration is made by first converting the emission limit in subsection (c)2. to pounds of VOC per gallon of coating solids as shown in the following three steps: 1) | lbs. VOC per gallons of coating minus water & exempt solvents | (Emission Limit From (C)2.) | = | volume fraction of VOC _____ 7.36 lbs. per gallon | (average density of solvents used to originally establish the emission limit) 2) | 1—Volume fraction | Volume fraction | = | volume fraction of solids 3) | lbs. VOC per gallons of coating minus water & exempt solvents | (Emission Limit From (C)2.) | = | Lbs. VOC _____ | _____ Volume fraction of solids | gallon of coating solids This value is the new compliance figure. The VOC per gallon of coating solids for each coating used is then determined using the method as specified in 40 CFR 60, appendix A—Test Methods, "Method 24—Determination of Volatile Matter Content, Water Content, Density, Volume, Solids and Weight Solids of Surface Coatings" using the one-hour bake. The composite daily volume-weighted average of pounds of VOC per gallon of coating solids as tested for in the actual coatings used is compared to the new compliance figure. Source operations on a coating line using coatings with a composite actual daily volume-weighted average value less than or equal to the new compliance figure are in compliance with this subsection. 3. As an alternative to the methods specified in (D)1. and 2. compliance with the emission limits specified in points (C)1. and 2. may be demonstrated by the implementation of an emission reduction equivalency compliance plan which utilizes a daily weighted average of emissions from a single or combination of source operations provided that: A. All source operations involved in the plan are subject to the emission limits of this subsection; B. All source operations are part of the same installation; C. The total actual VOC emissions for each twenty (24)-hour period do not exceed the sum of the allowable emissions determined from point (C) for each source operation for the same period; D. Equivalent emission reductions are accomplished in the time intervals allowed in point (C)2. as would be required for individual source operations; E. After December 24, 1987, testing of raw materials, emissions, equipment, or a combination of these, must be performed prior to initiation of an alternate compliance plan to verify any equivalent emission reductions claimed. All test methods and procedures, to be acceptable for use in the equivalency determination, must receive prior review and must have been approved by the director. Failure to gain test method and procedure approval of the director will invalidate the equivalency claim; and F. The overall plan is approved by the director. e. Record keeping. 1. The owner or operator of a coating line shall keep records detailing specific VOC sources, as necessary to determine compliance. These may include: (a) The type and the quantity of coatings used daily; (b) The coating manufacturer's formulation data for each coating on forms provided or approved by the director; (c) The type and quantity of solvents for coating, thinning, purging and equipment cleaning used daily; (d) All test results to determine capture and control efficiencies, transfer efficiencies and coating makeup; (e) The type and quantity of waste solvents reclaimed or discarded daily; (f) The quantity of pieces or materials coated daily; and (g) Any additional information pertinent to determine compliance. 2. Records, such as daily production rates, may be substituted for actual daily coating use measurement provided the owner submits a demonstration approvable by the director that these records are adequate for the purposes of this subsection. This will apply for all surface coating industries until the EPA issues national daily emissions record keeping protocols for specific industrial classifications. 3. Records required under subsections (6)a. and b. shall be retained by the owner or operator. (10) Restriction of emission of VOC from petroleum liquid storage loading and transfer. This subsection restricts volatile organic compound emissions from the handling of petroleum liquids in petroleum storage tanks with a capacity greater than 40,000 gallons, the loading of gasoline into delivery vessels and the transfer of gasoline from delivery vessels into stationary storage containers. Exemptions are provided for facilities that make transfers into stationary storage containers of certain sizes and types. This subsection is required in order to reduce hydrocarbon emissions that contribute to the formation of ozone. a. Petroleum storage tank. 1. No owner or operator of petroleum storage tanks shall cause or permit the storage in any stationary storage tank of more than 40,000 gallons capacity of any petroleum liquid having a true vapor pressure of 1.5 pounds per square inch absolute (psia) or greater at 90 degrees Fahrenheit (90 °F), unless the storage tank is a pressure tank capable of maintaining working pressures sufficient at all times to prevent volatile organic compound (VOC) vapor or gas loss to the atmosphere or is equipped with one of the following vapor loss control devices: A. A floating roof, consisting of a pontoon type, double-deck type or internal floating cover, or external floating cover, that rests on the surface of the liquid contents and is equipped with a closure seal(s) to close the space between the roof edge and tank wall. Storage tanks with external floating roofs shall meet the additional following requirements: i. The storage tank shall be fitted with either: a. A continuous secondary seal extending from the floating roof to the tank wall (rim-mounted secondary seal); or b. A closure or other device approved by the staff director that controls VOC emissions with an effectiveness equal to or greater than a seal required under point (A)1.(a)(I)[a] of this subsection; ii. All seal closure devices shall meet the following requirements: a. There are no visible holes, tears or other openings in the seal(s) or seal fabric; b. The seal(s) is intact and uniformly in place around the circumference of the floating roof between the floating roof and the tank wall; and c. For vapor-mounted primary seals, the accumulated area of gaps exceeding 0.32 centimeters, ⅛ inch width, between the secondary seal and the tank wall shall not exceed 21.2 cm 2 per meter of tank diameter (1.0 in 2 per foot of tank diameter) iii. All openings in the external floating roof, except for automatic bleeder vents, rim space vents and leg sleeves shall be equipped with: a. Covers, seals or lids in the closed position except when the openings are in actual use; and b. Projections into the tank which remain below the liquid surface at all times; iv. Automatic bleeder vents shall be closed at all times except when the roof is floated off or landed on the roof leg supports; v. Rim vents shall be set to open when the roof is being floated off the leg supports or at the manufacturer's recommended setting; and vi. Emergency roof drains shall have slotted membrane fabric covers or equivalent covers which cover at least 90 percent of the area of the opening; B. A vapor recovery system with all storage tank gauging and sampling devices gas-tight, except when gauging or sampling is taking place. The vapor disposal portion of the vapor recovery system shall consist of an adsorber system, condensation system, incinerator or equivalent vapor disposal system that processes the vapor and gases from the equipment being controlled; or C. Other equipment or means of equal efficiency for purposes of air pollution control as approved by the staff director. 2. Control equipment described in point (10)(A)1.(a) of this subsection shall not be allowed if the petroleum liquid other than gasoline has a true vapor pressure of 11.1 psia or greater at 90 degrees Fahrenheit. All storage tank gauging and sampling devices shall be gas-tight except when gauging or sampling is taking place. 3. Owners and operators of petroleum storage tanks subject to this subsection shall maintain written records of maintenance (both routine and unscheduled) performed on the tanks, all repairs made, the results of all tests performed and the type and quantity of petroleum liquid stored in them. b. This subsection shall not apply to petroleum storage tanks which: (a) Are used to store processed and/or treated petroleum or condensate when it is stored, processed and/or treated at a drilling and production installation prior to custody transfer; (b) Contain a petroleum liquid with a true vapor pressure less than 27.6 kilopascals (kPa) (4.0 psia) at 90 degrees Fahrenheit; (c) Are of welded construction, and equipped with a metallic-type shoe primary seal and have a shoe-mounted secondary seal or closure devices of demonstrated equivalence approved by the staff director; or (d) Are used to store waxy, heavy pour crude oil. c. Gasoline loading. 1. No owner or operator of a gasoline distribution facility or delivery vessel shall cause or permit the loading of gasoline into any delivery vessel from a distribution facility unless the distribution facility is equipped with a vapor recovery system or equivalent The delivery vessel shall be in compliance with part (10)(D) of this subsection. 2. Loading shall be accomplished in a manner that the displaced vapors and air will be vented only to the vapor recovery system. Measures shall be taken to prevent liquid drainage from the loading device when it is not in use or to accomplish complete drainage before the loading device is disconnected. The vapor disposal portion of the vapor recovery system shall consist of one of the following: a. An adsorber system, condensation system, incinerator or equivalent vapor disposal system that processes the vapors and gases from the equipment being controlled and limits the discharge of VOC into the atmosphere to ten milligrams of VOC vapor per liter of gasoline loaded; b. A vapor handling system that directs the vapor to a fuel gas system; or c. Other equipment of an efficiency equal to or greater than points (10)(B)2.(a) or (b) of this subsection if approved by the staff director. 3. Owners and operators of loading installations subject to this subsection shall maintain complete records documenting the number of delivery vessels loaded and their owners. 4. This subsection shall not apply to loading installations whose average monthly throughput of gasoline is less than or equal to 120,000 gallons when averaged over the most recent calendar year, provided that the installation loads gasoline by submerged loading. (a) Upon request of the director, these installations shall submit to the staff director, a report stating gasoline throughput for each month of the previous calendar year. (b) Delivery vessels purchased after the April 30, 2004 shall be stage I equipped. (c) Delivery vessels operated by an exempt installation shall not deliver to stage I controlled tanks unless the delivery vessel is equipped with and employs stage I controls. (d) A distribution facility that fails to meet the requirements of the exemption for one calendar year shall not qualify for the exemption again. (e) To maintain the exemption owners or operators shall maintain records of gasoline throughput and gasoline delivery. d. Gasoline transfer and store. 1. No owner or operator of a gasoline storage tank or delivery vessel shall cause or permit the transfer of gasoline from a delivery vessel into a gasoline storage tank with a capacity greater than 550 gallons unless: (a) The storage tank is equipped with a submerged fill pipe extending unrestricted to within six inches of the bottom of the tank, and not touching the bottom of the tank, or the storage tank is equipped with a system that allows a bottom fill condition; (b) All storage tank caps and fittings are vapor-tight when gasoline transfer is not taking place; and (c) Each storage tank is vented via a conduit that is: i. At least two inches inside diameter; ii. At least 12 feet in height above grade; and iii. Equipped with a pressure/vacuum valve that is CARB certified or equivalent as approved by the staff director. The pressure specifications for the pressure/vacuum valves shall be a positive pressure setting of 2.5 to six inches of water and a negative pressure setting of six to ten inches of water. 2. Stationary storage tanks with a capacity greater than 2,000 gallons shall also be equipped with a stage I vapor recovery system in addition to the requirements of paragraph (10)c.1. of this subsection and the delivery vessels to these tanks shall be in compliance with part (10)d. of this subsection. (a) The vapor recovery system shall collect no less than 90 percent by volume of the vapors displaced from the stationary storage tank during gasoline transfer and shall return the vapors via a vapor-tight return line to the delivery vessel. After the effective date of this subsection, all coaxial systems shall be equipped with poppeted fittings. (b) At the time of installation and every six years thereafter, each stage I vapor recovery system shall be tested according to subsection (10)f.1. of this rule. The department must be notified at least seven days prior to the test date to allow an observer to be present. It is not required for the department to be present to observe the test. The test results must be submitted to the staff director within 14 days of test completion. Each system has to be capable of meeting the static pressure performance requirement of the following equation: Pf = 2e-760.490/v Where: Pf = Minimum allowable final pressure, inches of water. v = Total ullage affected by the test, gallons. e = Dimensionless constant equal to approximately 2.718. 2 = The initial pressure, inches water. (c) Pressure/vacuum valves shall be tested according to subsection (10)(G)4. of this subsection at the time of installation and every three years thereafter. The department must be notified at least seven days prior to the test date to allow an observer the opportunity to be present. It is not required for the department to be present to observe the test. The test results must be submitted to the staff director within 14 days of test completion. The pressure specifications for pressure vacuum valves must be a positive pressure setting of 2.5 to six inches of water and a negative pressure setting of six to ten inches of water. The leak rate of each pressure/vacuum valve shall not exceed 0.4 cubic foot per hour at a pressure of two inches of water and 0.40 cubic foot per hour at a vacuum of four inches of water. (d) A delivery vessel shall be refilled only at installations complying with the provisions of part (10)c. of this subsection. (e) This subsection shall not be construed to prohibit safety valves or other devices required by governmental regulations. 3. No owner or operator of a gasoline delivery vessel shall cause or permit the transfer of gasoline from a delivery vessel into a storage tank with a capacity greater than 2,000 gallons unless: (a) The owner or operator employs one vapor line per product line during the transfer. The staff director may approve other delivery systems upon submittal to the department of test data demonstrating compliance with subparagraph (10)(C)2.(a). of this subsection; (b) The vapor hose(s) employed is no less than three inches inside diameter; (c) Each product hose employed is no more than four inches inside diameter; and (d) Any component of the vapor recovery system that is not preventing vapor emission as designed is repaired. 4. The owner or operator of a vapor recovery system subject to this part shall maintain records of inspection reports, enforcement documents, gasoline deliveries, routine and unscheduled maintenance, repairs, and all results of tests conducted. Unless otherwise specified in this rule, records have to be kept for two years and made available to the staff director within five business days of a request. 5. The provisions of paragraph (10)(C)2. of this subsection shall not apply to transfers made to storage tanks equipped with floating roofs or their equivalent. 6. The provisions of paragraphs (10)(C) 1.-4. of this subsection shall not apply to stationary storage tanks having a capacity less than or equal to 2,000 gallons used exclusively for the fueling of implements of agriculture or were installed prior to June 12, 1986. e. Gasoline delivery vessels. 1. No owner or operator of a gasoline delivery vessel shall operate or use a gasoline delivery vessel which is loaded or unloaded at an installation subject to subsections (10)(B) or (C) of this subsection unless: (a) Cargo tank tightness test is conducted annually; (b) The owner or operator obtains the completed test results signed by a representative of the testing facility upon successful completion of the leak test; (c) The delivery vessel is repaired by the owner or operator and retested within 15 days of testing if it does not pass the cargo tank tightness test; and (d) A copy of the vessel's current cargo tank tightness test results are kept with the delivery vessel at all times and made immediately available to the staff director upon request. 2. This part shall not be construed to prohibit safety valves or other devices required by governmental regulations. f. Owner/operator compliance. The owner or operator of a vapor recovery system subject to this subsection shall: 1. Operate the vapor recovery system and the gasoline loading equipment in a manner that prevents— (a) Gauge pressure from exceeding 4,500 pascals (18 inches of water) in the delivery vessel; (b) A reading equal to or greater than 100 percent of the lower explosive limit (LEL, measured as propane) at 2.5 centimeters from all points on the perimeter of a potential leak source when measured by the method specified in 40 CFR Part 60 appendix A—Test Methods, "Method 21—Determination of Volatile Organic Compound Leaks" during loading or transfer operations; (c) Visible liquid leaks during loading or transfer operation; 2. Repair and retest within 15 days, a vapor recovery system that exceeds the limits in part(10)(E) of this subsection; and 3. The owner or operator of a vapor recovery system subject to part (10)(E) of this subsection shall maintain records of inspection reports, enforcement documents, gasoline deliveries, routine and unscheduled maintenance, repairs, and all results of tests conducted. Unless otherwise specified in this rule, records shall be kept for two years and made available to the staff director within five business days of a request. g. Reporting and record keeping. The reporting and record keeping requirements are located in paragraphs (10)(A)3., (10)(B)3., (10)(C)4., and (10)(E)3. of this subsection. In addition, all records shall be maintained for a minimum of two years, and shall be made immediately available to inspectors upon request. h. Test methods. 1. Testing procedures to determine compliance with subparagraph (10)(D)1.(a) shall be performed according to 40 CFR 63.425(e), subpart R. 40 CFR 63.425(e), Subpart R, promulgated as of June 30, 2018 is hereby incorporated by reference in this rule, as published by the Office of the Federal Register. Copies can be obtained from the U.S. Publishing Office Bookstore, 710 N. Capitol Street NW, Washington, DC 20401. This rule does not incorporate any subsequent amendments or additions. 2. Testing procedures to determine compliance with subparagraph (10)(B)2.(a) of this rule shall be conducted using Method 25— Determination of Total Gaseous Nonmethane Organic Emissions as Carbon as specified in 10 CSR 10-6.030(22) or by any method determined by the staff director. 3. The staff director, at any time, may monitor a delivery vessel, vapor recovery system or gasoline loading equipment by a method determined by the staff director to confirm continuing compliance with this subsection. 4. Testing procedures to determine compliance with subparagraph (10)(C)2.(c). of this rule shall be conducted using California Air Resources Board Vapor Recovery Test Procedure TP-201.1E—Leak Rate and Cracking Pressure of Pressure/Vacuum Vent Valves, adopted October 8, 2003, or by any method determined by the staff director. Test Procedure TP-201.1E is hereby incorporated by reference in this rule, as published by the California Air Resources Board. Copies can be obtained from the California Air Resources Board, PO Box 2815, Sacramento, CA 95812. This rule does not incorporate any subsequent amendments or additions. 5. Testing procedures to determine compliance with subparagraph (10)(C)2.(b) of this subsection shall be conducted using California Air Resources Board Vapor Recovery Test Procedure TP-201.3—Determination of 2- Inch WC Static Pressure Performance of Vapor Recovery Systems of Dispensing Facilities, adopted April 12, 1996, and amended March 17, 1999, or by any method determined by the staff director. Test Procedure TP-201.3 is hereby incorporated by reference in this rule, as published by the California Air Resources Board. Copies can be obtained from the California Air Resources Board, PO Box 2815, Sacramento, CA 95812. This rule does not incorporate any subsequent amendments or additions. (11) Restriction of emission of VOC from rotogravure and flexographic printing facilities. This subsection applies to installations with uncontrolled potential emissions equal to or greater than 250 kilograms per day or 100 tons per year of volatile organic compounds (VOC) from the combination of rotogravure and flexographic printing presses. The uncontrolled potential emissions are the potential emissions (as defined) plus the amount by weight of VOCs whose emission into the atmosphere is prevented by the use of air pollution control devices. (A) Emission limits. 1. No owner or operator shall use or permit the use of any of the following printing presses unless they are equipped with a control device. The control device shall remove, destroy or prevent the emission of VOCs into the ambient air by at least the percentage indicated by weight of the uncontrolled VOC emissions on a daily basis. Printing Press | Percentage Flexographic | 60 Publication rotogravure | 75 Other rotogravure | 65 2. Low solvent technology may be used as a means of control to achieve VOC reductions instead of the methods required in subsection (A)1., if low solvent technology is used, the following limits must be met for each press: (a) For waterborne inks, the volatile portion of the ink as applied to the substrate must contain no more than 25 percent by volume of VOC; and (b) For water-based or high solids inks, the ink as applied to the substrate must be at least 60 percent by volume non-VOC material. 3. No owner or operator shall use or permit the use of any flexographic or rotogravure printing press that uses cleanup solvents containing VOCs unless: (a) The cleanup solvents are kept in tightly covered tanks or containers during transport and storage; (b) The cleaning cloths used with the cleanup solvents are placed in tightly closed containers when not in use and while awaiting off-site transportation. The cleaning cloths should be properly cleaned and disposed of. The cloths, when properly cleaned or disposed of, are processed in a way that as much of the solvent as practicable is removed for some further use or destroyed. Cleaning and disposal methods shall be approved by the director; and (c) An owner or operator may use an alternate method for reducing cleanup solvent VOC emissions, including the use of low VOC cleanup solvents, if the owner or operator shows the emission reduction is equal to or greater than paragraphs (A)3.(a) and (b) This alternate method must be approved by the director. (B) Record keeping 1. For owners or operators using an add-on control device to meet the requirements of paragraph (A)1., the following parameters shall be monitored and recorded to determine compliance with paragraph (A)1.: (a) Exhaust gas temperature of all incinerators or temperature rise across a catalytic incinerator bed on a continuous basis; (b) VOC breakthrough on a carbon adsorption unit on a continuous basis; (c) Results of emissions testing as required in part (C) of this subsection when performed; (d) Maintenance, repairs and malfunction of any air pollution control equipment when performed; and (e) Any other monitoring parameter required by the director to determine compliance with subsection (A)1. 2. For owners or operators meeting the requirements of paragraph (A)2. for each ink formulation used, the following shall be recorded for each press to determine continuous compliance with paragraph (A)2.: (a) Volume-weighted ink VOC content in percent by volume for each ink formulation as applied on a monthly basis; (b) Results of ink testing as required in part (C) of this subsection when performed; and (c) Any other information required by the director to determine compliance with subsection (A)2. 3. For owners and operators using low solvent technology without the use of control equipment to meet the requirements of paragraph (A)2., and for who subsection (B)2. does not apply, the following shall be recorded to determine daily compliance with subsection (A)2.: (a) Volume-weighted ink VOC content in percent by volume for each ink formulation as applied on a monthly basis; (b) Ink usage in gallons for each ink formulation as applied on a daily basis for each press; (c) Volume-weighted density of VOCs in ink in pounds per gallon for each ink formulation as applied on a daily basis; (d) Volume-weighted average of the VOC content of each ink formulation applied in percent by volume for each press on a daily basis; (e) Ink water content in percent by volume for each ink formulation as applied on a daily basis for each press; (f) Ink exempt solvent content in percent by volume for each ink formulation as applied on a daily basis for each press; (g) Results of ink testing as required in part (C) of this subsection when performed; and (h) Any other information required by the director to determine compliance with subsection (A)2. 4. Records of all information required in subsections (4) a. through c. shall be kept for at least two years. These records shall be available immediately upon request for review by air quality program personnel and other air pollution control agencies with proper authority. (C) Determination of compliance. 1. Testing and compliance demonstrations for the emission limits of paragraph (A)1. shall follow the procedures as specified in 40 CFR 60, appendix A—Test Methods, "Method 25—Determination of Total Gaseous Nonmethane Organic Emissions as Carbon" and 10 CSR 10-6.030 (20). The averaging time for these tests shall be three one-hour tests. These procedures will determine control device capture efficiency and destruction efficiency. Control device testing will be required as the director determines necessary to verify the capture and destruction efficiencies. At a minimum, control device testing must be completed and submitted once to the appropriate air pollution control agency within 180 days (August 4, 1992) after this provision of the subsection is effective (February 6, 1992), unless the director determines that a valid test is already on file. Inlet and outlet gas temperature rise across a catalytic incinerator shall be used to determine daily compliance. These temperatures shall be monitored with an accuracy of the greater of plus or minus 0.75 percent of the temperature being measured expressed in degrees Celsius or 2.5 degrees Celsius. 2. Testing and compliance demonstrations for the emission limits of subsection (A)2. shall follow the procedures as specified in 40 CFR 60, appendix A—Test Methods, "Method 24—Determination of Volatile Matter Content, Water Content, Density, Volume, Solids and Weight Solids of Surface Coatings." This procedure will determine the VOC content of inks. Ink testing will be required as the director determines necessary to verify the manufacturer's formula specifications. At a minimum, ink testing will be required once after this provision of the subsection is effective (February 6, 1992). Ink manufacturer's formula specifications shall be used to determine daily compliance. (12) Restriction of emissions of perchloroethylene dry cleaning installations. Reserved. (13) Control of emissions from the manufacturing of paints, varnishes, lacquers, enamels and other allied surface coating products. (A) Applicability. This subsection applies to those installations which have the uncontrolled potential to emit more than 250 kilograms per day or 100 tons per year of volatile organic compounds (VOC) from the manufacture of paints, varnishes, lacquers, enamels and other allied surface coating products. This does not include any installation which does not have an allowable VOC emission limit established under 10 CSR 10-6.060 or legally enforceable state implementation plan revision and which has uncontrolled potential emissions less than 250 kilograms per day or 100 tons per year. The uncontrolled potential to emit is the potential emissions (as defined) plus the emissions removed by control devices. (B) General rule. No owner or operator of a manufacturing installation subject to this subsection and producing the products listed in paragraph (A) shall cause or allow the manufacture of these products unless the operating equipment meets the requirements contained in this subsection and without adhering to operating procedures recommended by the equipment manufacturer and approved by the director. (C) Operating equipment and operating procedure requirements. 1. Tanks storing VOC with a vapor pressure greater than or equal to ten kilo pascals (1.5 psi) at 20 degrees Celsius, shall be equipped with pressure/vacuum conservation vents set at 0.2 kPa (.029 psi), except where more effective air pollution control is used and has been approved by the director. Stationary VOC storage containers with a capacity greater than 250 gallons shall be equipped with a submerged-fill pipe or bottom fill, except where more effective air pollution control is used and has been approved by the director. 2. Covers shall be installed on all open-top tanks used for the production of nonwaterbase coating products. These covers shall remain closed except when production, sampling, maintenance or inspection procedures require operator access. 3. Covers shall be installed on all tanks containing VOC used for cleaning equipment. These covers shall remain closed except when operator access is required. 4. All vapors from varnish cooking operations shall be collected and passed through a control device which removes at least 85 percent of the VOCs from these vapors before they are discharged to the atmosphere. 5. All grinding mills shall be operated and maintained in accordance with manufacturer's specifications. The manufacturer's specifications shall be kept on file and made available to the director upon his/her request. 6. The polymerization of synthetic varnish or resin shall be done in a completely enclosed operation with the VOC emissions controlled by the use of surface condensers or equivalent controls. (a) If surface condensers are used, the temperature of the exit stream shall not exceed the temperature at which the vapor pressure is 3.5 kPa (0.5 psi) for any organic compound in the exit stream. (b) If equivalent controls are used, the VOC emissions must be reduced by an amount equivalent to the reduction which would be achieved under paragraph (C)6.(a) Any owner or operator desiring to use equivalent controls to comply with this subsection shall submit proof of equivalency as part of the control plan required. Equivalent controls may not be used unless approved by the director. (D) Compliance methods and record keeping. 1. The VOC control efficiency in paragraphs (C)4. and 6. shall be determined by the testing methods as specified in 40 CFR 60, appendix A—Test Methods, "Method 25—Determination of Total Gaseous Nonmethane Organic Emissions as Carbon." The same method shall be used to sample emissions from alternate control measures subject to the director's review in subsection (C)1. 2. Owners or operators utilizing add-on control technology shall monitor the following parameters continuously while the affected equipment is in operation: (a) Exit stream temperature on all condensers; (b) Routine and unscheduled maintenance and repair activities on all air pollution control equipment; and (c) Any other parameter which the director determines is necessary to quantify emissions or otherwise determine compliance with this subsection. 3. Records shall be kept on production rates sufficient to determine daily VOC emissions and any equipment test results performed in conjunction with this subsection. 4. The owner or operator shall maintain all recorded information required under subsections (D)2. and 3. and shall keep the records for a period of not less than two years. All these records shall be made available to the director upon his/her request. (14) Control of emissions from the application of automotive underbody deadeners. Reserved. (15) Control of emissions from production of pesticides and herbicides. This subsection restricts emissions of volatile organic compounds from the production of pesticides and herbicides. (A) Applicability. 1. This subsection shall apply to any pesticide or herbicide manufacturing installation with an uncontrolled potential to emit equal to or greater than 250 kilograms per day or 100 tons per year of volatile organic compounds (VOCs). This subsection shall also apply to any installation which does not have an allowable VOC emission limit established under 10 CSR 10-6.060 or legally enforceable state implementation plan revision and which has uncontrolled potential emissions greater than or equal to 250 kilograms per day or 100 tons per year of VOC. The uncontrolled potential to emit is the potential emissions (as defined) plus the emissions removed by control devices. 2. This subsection does not apply to source operations used exclusively for chemical or physical analysis or determinations of product quality and commercial acceptance (such as pilot plant operations and laboratories) unless the operation is an integral part of the production process. (B) General provisions. All source operations in installations affected by this subsection that are venting emissions to VOC emission control devices as of November 23, 1987 shall be required to continue venting emissions to these control devices and these emissions shall be controlled to the extent required in subsection (C) of this section. (C) Emission limitations. Any pesticide or herbicide manufacturing installation using VOC emissions control devices subject to this subsection must achieve an instantaneous VOC destruction or removal efficiency greater than or equal to 99 percent. (D) Record keeping 1. Owners or operators utilizing thermal oxidizers as control technology must maintain adequate records of the combustion chamber temperature and residence time to determine the VOC control compliance. Also, the owners or operators must maintain records of routine or unscheduled maintenance and repairs of the thermal oxidizers. The director may require any other records of operating parameters as may be necessary to determine compliance. 2. Owners or operators using other control technology shall maintain records of all operating parameters and routine or unscheduled maintenance and repairs of air pollution control equipment as may be required by the director to determine compliance. 3. Records of all information required in paragraphs (D)1. and 2. shall be kept for a period of not less than two years and all these records shall be made available to the director upon their request. (E) Compliance method. 1. For any control technology employed to comply with this subsection, compliance shall be determined by the test method as specified in 40 CFR 60, appendix A—Test Methods, "Method 25—Determination of Total Gaseous Nonmethane Organic Emissions as Carbon." 2. For thermal oxidizers, compliance shall be determined by the combustion chamber temperature and residence time after adequate test results, as determined by the director, are provided by the owners or operators. These test results shall be subject to periodic confirmation at the discretion of the director. Combustion chamber gas temperature shall be monitored with an accuracy of the greater of ± 0.75 percent of the temperature being measured expressed in degrees Celsius or 2.5 degrees Celsius. (16) Control of gasoline Reid vapor pressure. This subsection limits the volatility of motor vehicle gasoline. By reducing the amount of gasoline that evaporates into the atmosphere, emissions of volatile organic compounds will be reduced. Since volatile organic compounds are precursors to ozone formation, ambient ozone levels will be reduced. (A) General provisions 1. No person shall sell, dispense, supply, offer for sale, offer for supply, transport, or exchange in trade for use gasoline intended for final use in the applicable areas that exceeds the Reid Vapor Pressure (RVP) limit in paragraph (A)2. 2. The RVP of gasoline that is subject to this section shall be restricted as follows: RVP (psi) | Facility | Time Period 7.0 or less | All facilities | 6/1 through 9/15 3. Gasoline blends having at least nine percent but not more than ten percent ethyl alcohol by volume of the bended mixture shall have an RVP limit of one pound per square inch (psi) higher than the limit contained in paragraph (A)2. (B) Gasoline sampling procedures. Gasoline sampling shall follow the procedures outlined ASTM D4057-06(2011) Standard Practice for Manual Sampling of Petroleum and Petroleum Products, as published August 2011 (approved June 1, 2011). This standard is incorporated by reference in this rule, as published by American Society for Testing and Materials (ASTM) International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. This rule does not incorporate any subsequent amendments or additions. (C) Gasoline testing procedures for RVP and determination of compliance. 1. Gasoline testing shall follow the procedures contained in either ASTM D6378-10 Standard Test Method for Determination of Vapor Pressure (VPX) of Petroleum Products, Hydrocarbons, and Hydrocarbon-Oxygenate Mixtures (Triple Expansion Method), as published November 2010 (approved October 1, 2010) or ASTM D5191-10b Standard Test Method for Vapor Pressure of Petroleum Products (Mini Method), as published November 2010 (approved October 1, 2010). These standards are incorporated by reference in this subsection, as published by American Society for Testing and Materials (ASTM) International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. This subsection does not incorporate any subsequent amendments or additions. 2. To determine compliance when field analysis indicates the RVP is between 7.0 psi and 7.3 psi for conventional gasoline or between 8.0 psi and 8.3 psi for nine to ten percent ethyl alcohol blends, city health department's air quality program will conduct additional testing. Additional testing shall include independent analysis by three separate laboratories of three independent samples taken sequentially, in accordance with sections (4) and (5) of this rule. If all of the measured RVP of the samples are above 7.0 psi for conventional gasoline or above 8.0 psi for nine to ten percent ethyl alcohol blends, the department may take enforcement action. (D) Record keeping. 1. All persons subject to this subsection shall maintain records of any RVP testing and test results during the compliance period specified in part (A). These records shall be kept for at least two years after the date of a completed RVP test These records shall be available immediately upon request for review by city health department's air quality program personnel and Department of Natural Resources personnel and city and county personnel certified under RSMo 643.140. 2. Each bill of lading, invoice, loading ticket, delivery ticket, and other document that accompanies a shipment of gasoline (which includes gasoline blended with ethyl alcohol) shall contain a legible and conspicuous statement that the RVP of the gasoline does not exceed 7.0 psi, in accordance with this rule for conventional gasoline, or that the RVP does not exceed 8.0 psi for nine to ten percent ethyl alcohol blends. 3. Each bill of lading, invoice, loading ticket, delivery ticket, and other document which accompanies a shipment of gasoline containing ethyl alcohol shall contain a legible and conspicuous statement that the gasoline being shipped contains ethyl alcohol and that the percentage concentration of ethyl alcohol is between nine percent to ten percent, as required under paragraph (A)3. of this subsection. 4. All persons subject to this subsection shall keep records of the bill of lading, invoice, loading ticket, delivery ticket, and other documents accompanying a shipment of gasoline during the compliance period specified in part (A). These records shall be kept for at least two years after the date of delivery. These records shall be made available immediately upon request for review or duplication by Department of Natural Resources personnel and city and county personnel certified under RSMo 643.140. 5. The director may require additional record keeping on a case-by-case basis. The director may require records be kept for additional periods of time for enforcement compliance. (E) Violations and penalties. Persons violating this regulation shall be subject to enforcement action. (F) Exceptions. 1. Gasoline that exceeds the RVP limits will not violate this subsection if that gasoline is separately stored, sealed, clearly labeled and not used until it is in compliance with this subsection. The label shall state that the gasoline is prohibited by Missouri law from being sold, dispensed, supplied, offered for sale, offered for supply, transported or exchanged in trade until the specific date when that activity will be in compliance with this subsection. 2. An individual consumer of gasoline who dispenses gasoline into his/her personal motor vehicle is exempt from this subsection. 3. Gasoline used only to fuel agricultural vehicles on property zoned for agricultural use is exempt from this subsection. 4. Owners and operators of facilities that dispense gasoline into individual motor vehicles are not required to conduct RVP testing specifies in part (C). 5. Federal specification reformulated gasoline (RFG) fully satisfies the requirements of part (A) of this subsection. (17) Control of emissions from lithographic printing facilities. This subsection restricts volatile emissions form lithographic printing facilities. (A) Applicability. This subsection shall apply to installations that have calculated actual volatile organic compound (VOC) emissions for a known number of crewed hours, increased by the amount by weight of VOCs whose emission into the atmosphere is prevented by the use of air pollution control devices and extrapolated to 8,760 hours per year to be equal to or greater than 100 tons per year from offset lithographic printing presses after December 9, 1991. The following factors shall be taken into consideration unless an alternative method is approved by the director. 1. The installation shall assume 50 percent of the solvent used for cleanup is retained in the rag(s) when the used solvent- laden rag(s) are cleaned or disposed of. The installation must demonstrate to the director that the solvents are not evaporated into the air when the waste rags are properly cleaned and disposed of; 2. The installation shall assume 40 percent of the heatset ink oils stay in the paper web; 3. The installation shall assume no VOCs are emitted from the inks used in sheet-fed presses and nonheatset web presses; and 4. The installation may assume that 50 percent of the alcohol from the fountain solution is emitted from the dryer. 5. This regulation shall not apply to: (a) Printing on fabric, metal or plastic; (b) Sheet-fed lithographic presses with cylinder widths of 26 inches or less; or (c) Web lithographic presses with cylinder widths of 18 inches or less. (B) General provisions. 1. No owner or operator shall use or permit the use of any offset lithographic printing press unless: (a) The fountain solution contains 10 percent or less by weight of alcohol; (b) The fountain solution is refrigerated to a temperature of 55 degrees Fahrenheit or less for alcohol-based solutions; (c) The fountain solution temperature at the mixing tank for alcohol-based solutions is monitored during each shift; and (d) The fountain solution mixing tanks are covered for alcohol-based solutions. 2. No owner or operator shall use or permit the use of any offset lithographic printing press that uses cleanup solvents containing VOCs unless: (a) The cleanup solvents are kept in tightly covered tanks or containers during transport and storage; (b) The cleaning cloths used with the cleanup solvents are placed in tightly closed containers when not in use and while awaiting off-site transportation. The cleaning cloths should be properly cleaned and disposed of: The cloths, when properly cleaned or disposed of; are processed in a way that as much of the solvent, as practicable, is recovered for further use or destroyed. Cleaning and disposal methods shall be approved by the director; and (c) An owner or operator may use an alternate method for reducing cleanup solvent VOC emissions, including the use of low VOC cleanup solvents, if the owner or operator shows the emission reduction is equal to or greater than those in paragraphs (B)2.(a) and (b). This alternate method must be approved by the director. 3. No owner or operator shall use or permit the use of any heatset web-offset lithographic printing press that uses a dryer that has ever had an actual emission rate often tons per year or more VOCs after December 9, 1991, unless 100 percent of the dryer exhaust is ducted to a control device that achieves 85 percent by weight or greater control efficiency. 4. Use of emission control equipment shall require that continuous monitors be installed, calibrated, operated and maintained. The monitors continuously shall measure: (a) The exhaust gas temperature of all VOC destruction devices and the gas temperature immediately upstream and downstream of catalytic bed with an accuracy of plus or minus 0.75 percent measured in degrees Celsius, or 2.5 degrees Celsius; (b) The cumulative amount of VOC recovered during a calendar month for all VOC recovery equipment attached to a dryer with an accuracy of plus or minus two percent; and (c) Any other parameters considered necessary by the director to verify proper operation of emission control equipment. (C) Record keeping. 1. All persons subject to this subsection shall maintain records as required by this part sufficient to determine continuous compliance with this subsection These records shall be kept for at least two years. These records shall be available immediately upon request for review by air quality program personnel and other air pollution control agencies with proper authority. 2. All persons subject to paragraph (B)3. shall maintain records for each control device sufficient to demonstrate that the control efficiency is being maintained. 3. For each regulated printing press, records shall be maintained to show: (a) Quantity of alcohol added to the fountain solution of each regulated press in pounds each month; (b) Percent of alcohol in fountain solution by weight as monitored on a once per shift basis; (c) Results of any testing conducted on an emission unit at a regulated installation; (d) Maintenance records of any air pollution control equipment; and (e) The temperature of alcohol-based fountain solution as recorded on a once per shift basis. 4. For each lithographic installation subject to this subsection, records shall be maintained to show: (a) Properties of heatset inks as applied (determined by the manufacturer's formulation data), density of inks in pounds per gallon, and total VOC content in weight percent; (b) Quantity of heatset inks as applied to substrate in pounds on a monthly basis; (c) Quantity of cleanup solvents used on a monthly basis; and (d) Quantity of coatings used on a monthly basis and percent VOC in coating by weight on a formulation basis. 5. The director may require other records as reasonable and necessary to carry out the provisions of this Code. (D) Compliance. 1. All persons subject to the provisions of this subsection shall provide to the director for approval a demonstration of final compliance with subsection (B)1. (a) Upon startup of presses which are not in existence and operating on December 9, 1991; 2. All persons subject to the provisions of this subsection shall provide to the director for approval a demonstration of final compliance with subsections (B)2. and 3. (a) Upon startup of presses which are not in existence and operating on December 9, 1991; and (E) Testing procedures. 1. Testing and compliance demonstrations for paragraph (B)3. of this subsection shall follow the procedures contained in Environmental Protection Agency Reference Methods 25 or 25A found in 40 CFR 60, appendix A. 2. Testing and compliance demonstrations for paragraph (B)1.(a) of this subsection shall be based on the results from a calibrated hydrometer or refractometer.

(Ord. No. 220226, § 1, 6-30-22)

Ask a question about Kansas City law

Corpus searches the Kansas City sections it holds and shows the ones that match, with their citations. Free, no sign-in.