11.79.330 - Disinfection.
Chlorine is considered to be the most desirable disinfectant for swimming pools. Other disinfectants may be accepted upon submission of acceptable proof of their effectiveness. All pools shall be equipped with a chlorinator or other residual disinfectant feeder which meets the following requirements. A. Design and Construction. Disinfectant feeders shall be constructed of materials that will withstand wear, corrosion or attack by disinfectant solutions or vapors and which are not adversely affected by repeated regular adjustments or other conditions anticipated in the use of the device. The feeder shall be capable of being easily disassembled for cleaning and maintenance. The design and construction shall be such as to preclude stoppage from chemicals intended to be used or foreign materials that may be contained therein. The feeder shall incorporate failure-proof features so that the disinfectant cannot feed directly into the pool, pool piping, or pool enclosure under any type of failure of the equipment or its maintenance. B. Capacity. The disinfectant feeder shall be capable of maintaining at least the equivalent of one (1) part per million of free available chlorine in all portions of the pool under conditions of operation to be anticipated at the proposed installation. This usually requires application of at least ten (10) ppm of available disinfectant based on the recirculation rate. C. Sensitivity. The disinfectant feeder shall have a graduated and clearly marked dosage adjustment to provide flows from full capacity to twenty-five (25) percent of such capacity. The device shall be capable of continuous delivery within ten (10) percent of the dosage at any setting. Gas Chlorination. When chlorine gas is used, the following additional features shall be provided. A. A water operated chlorinator shall be used which controls and regulates the flow of gas. This unit shall provide an automatic shut off of gas when water pressure fails and shall vent leakage to outside atmosphere. B. The chlorinator shall be capable of delivering chlorine at its maximum rate without releasing chlorine to the atmosphere. C. The mechanical proportioning device and cylinders of chlorine shall be housed in a reasonably gas-tight corrosion-resistant and mechanically vented enclosure. Air tight ducts from the bottom of the enclosure to atmosphere in an unrestricted area and a motor driven exhaust fan capable of producing at least one (1) air change per minute and automatic louvers of good design near the top of the enclosure for admitting fresh air required. Electrical switches for the enclosure adjacent to the door. D. Chlorine cylinders shall be anchored to prevent their falling over. Keys shall be maintained on the chlorine cylinder so that supply can be shut off quickly in the case of an emergency. Cylinders shall be stored in an upright position and protected against direct exposure to the sun. E. Scales shall be provided for weighing chlorine cylinders. Scales shall be of corrosive-resistant material, and accurate enough to indicate the loss of weight to the nearest one-quarter (¼) pound. Scales and chlorine cylinders should be placed on platforms raised above floor level. F. A gas mask approved by the U.S. Bureau of Mines for use in a chlorine atmosphere shall be available. A replacement canister shall be provided and a record shall be kept of gas mask usage that the mask will be serviceable when needed. G. The gas mask shall be kept in a closed cabinet accessible without a key, located outside of the room in which the chlorinator is maintained. H. A Chlorine Institute approved safety kit should be stored outside or be near the room where the chlorine cylinders are stored and used. I. Below ground installation of chlorination equipment will not be considered except in unusual circumstances. Dry Feed Chlorinators. Chlorinators utilizing dry chemicals in powder, stick, tablet or any other form which feed the chemical into the water through erosion or any other manner are restricted in use to pools containing gallonage as recommended by the manufacturer and approved by the National Sanitation Foundation (NSF). Chlorine Residual. Where chlorine, hypochlorite, or other chlorine compounds are used for disinfection, tests must be made as often as necessary to maintain adequate residuals. A free chlorine residual between one (1) ppm and three (3) ppm shall be maintained throughout the pool. If cyanuric acid or chlorinated isocyanurates are used, the following additional requirements shall be met: A. A cyanuric acid test kit shall be provided. B. The cyanuric acid level in the pool shall be kept below one hundred (100) ppm. C. A free chlorinated residual of at least 1.5 ppm shall be maintained throughout the pool.
(1994 C., § 11.79.330; Ord. No. 65567, § 33, 2002.)
Ask a question about St. Louis law
Corpus searches the St. Louis sections it holds and shows the ones that match, with their citations. Free, no sign-in.