Minimum Space and Occupancy Standards
SEA-MC tit. 22, subtit. II, ch. 22.206, subch. I
in effectSeattle Mun. Code ch. 22.206, subch. I, § 22.206.020 Floor area
22.206.020 - Floor area
A. Every dwelling unit shall have at least one habitable room, which shall have not less than 120 square feet of floor area.
B. No habitable room except a kitchen may be less than 7 feet in any floor dimension.
C. Every room used for sleeping purposes, including an SRO unit, shall have not less than 70 square feet of floor area. Every room, except an SRO unit, which is used for both cooking and living or both living and sleeping quarters shall have a floor area of not less than 130 square feet if used or intended to be used by only one occupant, or of not less than 150 square feet if used or intended to be used by two occupants. Where more than two persons occupy a room used for sleeping purposes, the required floor area shall be increased at the rate of 50 square feet for each occupant in excess of two.
D. In a dormitory, minimum floor area shall be 60 square feet per single or double bunk, and aisles not less than 3 feet in width shall be provided between the sides of bunks and from every bunk to an exit. The requirements of this subparagraph shall not apply to SRO units.
E. The required floor area square footage of all dwelling units, dormitories, and SRO units shall not include built-in equipment which extends from the floor to 30 inches above the floor, including but not limited to wardrobes, cabinets, and kitchen sinks or appliances.
(Ord. 125343, § 2, 2017; Ord. 115671, § 9, 1991; Ord. 113545 § 5, 1987.)
Seattle Mun. Code ch. 22.206, subch. I, § 22.206.030 Reserved.
Seattle Mun. Code ch. 22.206, subch. I, § 22.206.040 Light and ventilation
22.206.040 - Light and ventilation
A. Every habitable room in a housing unit shall have a window or windows providing natural light with an area of not less than 8 percent of the floor area of the room, but in no event shall such area be less than 10 square feet; provided, that an approved system of artificial light compliant with current Seattle Building Code standards may be used in lieu of the window or windows required by this section.
B. Every habitable room in a housing unit and every laundry room shall have natural ventilation from an exterior opening with an area measuring at least 4 percent of the floor area of the room. In lieu of required exterior openings for natural ventilation in all habitable rooms and in laundry rooms, a mechanical ventilating system may be provided. Such system shall comply with the requirements of the Seattle Energy Code in effect on the date of installation and applicable requirements of the Mechanical Code.
C. Every bathroom and water closet compartment shall be provided with natural ventilation by means of exterior openings with an area not less than five percent of the floor area of the room, but in no event shall such area be less than 1.5 square feet; provided, that in lieu of required exterior openings for natural ventilation, a mechanical ventilating system or vent shafts may be provided. Such system shall comply with the requirements of the Seattle Energy Code in effect on the date of installation and applicable requirements of the Seattle Mechanical Code. If a mechanical ventilation system is provided in laundry rooms or similar rooms, it shall be connected to the outside.
D. For the purpose of determining light and ventilation requirements, any room may be considered a portion of an adjoining room if 1/2 of the area of the common wall is open and unobstructed and provides an opening of not less than 1/10 of the floor area of the interior room or 25 square feet, whichever is greater.
E. Required exterior openings for natural light or natural ventilation shall open directly onto a street or public alley, or a yard or court adjacent to the required exterior opening; provided, that required exterior openings may open onto a roofed porch where the porch:
1. Abuts a street, yard, or court; and
2. Has a ceiling height of not less than 6 feet, 8 inches; and
3. Is at least 65 percent open and unobstructed for its length, or is open at both ends.
F. Every yard, court, street, or alley having required windows facing thereon shall be not less than 3 feet in width and unobstructed to the sky.
(Ord. 125343, § 3, 2017; Ord. 123546, § 1, 2011; Ord. 115671, § 10, 1991; Ord. 113545 § 5, 1987.)
Seattle Mun. Code ch. 22.206, subch. I, § 22.206.050 Sanitation.
22.206.050 - Sanitation.
A. Dwelling Units. Every dwelling unit shall contain a toilet, a bathroom sink, and a bathtub or shower in a separate room or rooms which shall be accessible from inside the dwelling unit. The only access from a bedroom to the only bathroom shall not be through another bedroom. No toilet shall be located in any room or space used for the preparation of food, nor shall a room containing a toilet open directly into any such room or space unless the toilet room has a tight-fitting door.
B. Hotels. Every hotel that does not provide private toilets, bathroom sinks, bathtubs, or showers shall have on each floor, accessible from a public hallway, at least one toilet, one bathroom sink, and one bathtub with shower or one separate shower for each ten occupants or portion thereof. For each additional ten occupants, or portion thereof, an additional one toilet, one bathroom sink, and one bathtub with shower or separate shower accessible from a public hallway shall be provided.
C. Other Buildings. Every building, other than a hotel, containing housing units that do not have private toilets, bathroom sinks, and bathtubs or showers shall contain at least one toilet, one bathroom sink, and one bathtub or shower, accessible from a public hallway, for each eight occupants or portion thereof. On floors with fewer than eight housing units, the required sanitary facilities may be provided on an adjacent floor if the floor on which facilities are provided is directly and readily accessible to such occupants and if such use does not cause the facilities to be used by a total of more than eight persons.
D. Kitchens. Every dwelling unit shall have a kitchen. Every kitchen shall have an approved kitchen sink with at least 30 inches of floor space in front, hot and cold running water, counter work-space, and cabinets for storage of cooking utensils and dishes. A kitchen shall also have approved cooking appliances and refrigeration facilities or adequate space and approved gas or electric hookups for their installation. All cooking appliances and refrigeration facilities shall be maintained in a safe and good working condition by the owner or furnisher of the appliance. Unapproved cooking appliances shall be prohibited. Splash backs and countertops shall have an impervious surface.
E. Fixtures. All plumbing fixtures shall be trapped and vented and connected to an approved sanitary sewer or to an approved private sewage disposal system. All toilets shall be flush type and in good working order. Every discharge opening of the spout of a water supply outflow (faucet) shall be not less than 1 inch above the flood rim of the fixture into which it discharges.
F. Water Supply. There shall be an approved system of water supply, providing both hot and cold running water. Hot water for the required kitchen sink, bathroom sink, and bathtub or shower shall be provided at a temperature of not less than 100 degrees Fahrenheit at all times at the fixture outlet, to be attained within approximately two minutes after opening the fixture outlet. Prior to a new tenant occupying of a housing unit in which hot water is supplied from an accessible, individual water heater, the water heater shall be set by the owner at a temperature not higher than 120 degrees Fahrenheit or the minimum setting on any water heater which cannot be set at 120 degrees Fahrenheit; provided, that buildings, other than one- and two-family dwellings, in which hot water is supplied by a central water-heater system need not comply with this requirement.
G. Maintenance. All sanitary facilities, fixtures, equipment, structures, and premises, including gas piping and temperature pressure relief valves, shall be maintained in a safe and sanitary condition, and in good working order.
H. Fuel Shutoff Valves. An approved accessible shutoff valve shall be installed in the fuel-supply piping outside of each appliance and ahead of the union connection thereto, and in addition to any valve on the appliance. Shutoff valves shall be within 3 feet of the appliance. Shutoff valves may be located immediately adjacent to and inside or under an appliance when placed in an accessible and protected location and when such appliance may be removed without removal of the shutoff valve.
(Ord. 125343, § 5, 2017; Ord. 115671, § 11, 1991; Ord. 113545 § 5(part), 1987.)
Source: City of Seattle, Seattle Municipal Code and City Charter (Municode Library, library.municode.com)URL: https://library.municode.com/wa/seattle/codes/municipal_code?nodeId=TIT22BUCOCO_SUBTITLE_IIHOCO_CH22.206HABU_SUBCHAPTER_IMISPOCSTFetched: 11/1/2026