Interiors of buildings.
St. Louis Revised Code § 25.56.180
in effect25.56.180 - Interiors of buildings.
1. Sanitation. General unsanitary conditions shall not be allowed within public areas, dwelling units or basements. Trash, debris, rodent and insect infestation shall be eliminated.
2. Walls and ceilings. Plaster or tile shall not be missing, loose or broken. Required fire resistance assemblies shall be maintained. Wall coverings shall not be loose, water damaged or in bad repair.
3. Entry doors. Lock on entry door(s) shall be in good working order. Door(s) shall latch properly for privacy. If entry door is a fire door, it shall have an operable self closer. Common area entrance/exit door(s) where a door frame exists shall not be equipped with double key or clasp type locking mechanism.
4. Structural. Floors/joists shall not be missing, rotten, fire damaged, spalled, rusted or broken. Floor covering shall not be torn or broken. There shall be no unsafe structural conditions.
5. Safety. Sufficient exits shall be provided. Stair(s) shall not be missing, rotten, fire damaged, spalled, rusted or broken. Handrail(s) or guardrail(s) shall not be missing, rotted or broken. Operable entrance/exit doors shall be provided and maintained. Excessive storage of any material shall not be permitted. Operable smoke detectors shall be provided as required by ordinance.
6. Plumbing fixtures. No fixtures shall be missing, inoperable or defective. No pipe or fixture shall be leaking or improperly connected. Hot water heater shall be required. Hot water heater shall be operable, and properly vented. Hot water heater shall have a temperature/pressure relief valve.
7. Electrical equipment. Cover plates shall not be missing or broken. Switches or outlets shall be operable, and of sufficient number. Fuses/circuit breakers shall be properly sized. Lighting fixtures shall not be defective. Excessive, defective or hazardous extension cords shall not be allowed. Loose, hanging, frayed, bare wires or open splices shall be permitted. Defective or hazardous electrical services shall be prohibited.
8. Mechanical equipment. Heating unit shall be operable. Furnace shall be properly vented. Space heaters shall be properly vented (when applicable).
9. Space requirements. Occupancy load shall be limited to:
a. Minimum habitable gross floor area of one hundred fifty (150) square feet for first occupant, plus 100 square feet for each additional occupant; or
b. Sleeping room area of a minimum of seventy (70) square feet for first occupant, fifty (50) square feet for each additional occupant.
c. Children under the age of six (6) years old shall not count towards the occupancy load.
d. Minimum occupancy area requirements for living room and dining room as reflected in the applicable sections of Chapter Four of adopting Ordinance Number 70798 of the 2018 International Property Maintenance Code of the City of St. Louis.
e. Basement occupancies shall not be permitted unless they meet the following requirements:
1. Floors and walls are weather tight so as to prevent entry of moisture.
2. Minimum ceiling heights are in accordance with applicable sections of this chapter.
3. Means of egress and emergency escape requirements as reflected in the applicable sections of the current building code of the City of St. Louis.
f. Minimum ceiling height: Habitable spaces shall have a clear ceiling height over the minimum area required by this code at not less than seven (7) feet except that in attics or top half stories the ceiling height shall not be less than seven (7) feet over not less than one-third (⅓) of the minimum area required by this code when used for sleeping, study, or similar activity. In calculating the floor area of such rooms, only those portions of the floor area of the room having a clear ceiling height of five (5) feet or more shall be included.
Exception: Hallways, corridors, bathrooms, toilet rooms, and habitable basements used as recreation rooms shall have a ceiling height of not less than seven (7) feet to the lowest projection from the ceiling.
g. Every bedroom shall be equipped with an operable window which complies with the current adopted International Property Maintenance Code.
h. Toilet rooms and bathrooms shall be arranged and designed to provide privacy.
i. The required dining room shall be located on the same level as the required kitchen.
j. Kitchens, nonhabitable spaces, and public spaces shall not be used for sleeping purposes.
(Ord. No. 72025, § 1, 7-11-2025)
Source: City of St. Louis, Missouri, Revised Code of the City of Saint Louis, 2020, Annotated, and City Charter (Municode Library, library.municode.com)URL: https://library.municode.com/mo/st._louis/codes/code_of_ordinances?nodeId=TIT25BUCO_CH25.56HOCODI_25.56.180INBUFetched: 11/1/2026