Streets and storm sewers.
Round Rock Zoning and Development Code, art. VII, § 4-90
in effectSec. 4-90. - Streets and storm sewers.
(a) All street sections shall be in accordance with city standards with an allowable design drainage capacity for gutter flow no deeper than the top of the curb.
(b) Depth of flow in streets is to be controlled to allowable levels by modification of crossfall, gradient changes, or the use of curb inlets and storm sewers.
(c) Curb inlets shall be spaced as required to control flow in streets to allowable levels and placed to minimize interference of runoff to traffic flow, particularly at intersections.
(d) All storm sewer pipe shall be reinforced concrete, minimum size 18 inches diameter, and installed in compliance with the city's standard specifications for public works construction for the city.