For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 18.71.080 — Simplified analysis procedure

Long Beach Municipal Code (Supp. No. 53, Update 1: codified through Ordinance No. ORD-26-0027, enacted October 13, 2026) · Long Beach Municipal Code § 18.71.080

Corpus is an independent public-information project, not the official City of Long Beach website. Stable reference: corpuslaw.us/code/8a625cd8-8a5d-4819-be5f-714a45c00aa8

18.71.080 - Simplified analysis procedure.

A. General. Structures conforming to the requirements of this section may be analyzed for having a required strength by a simplified analysis procedure. B. Required features of the building. The building shall conform to all the following features, or the building shall be analyzed by the equivalent lateral force procedure or the dynamic lateral force procedure as prescribed by Subsection 18.71.050.D. 1. The lateral-resisting elements of the building shall be reinforced concrete shear walls or frames with solid masonry infills and infills which have openings in the masonry infills not exceeding ten percent (10%) of the gross area of the infill panel which has the opening(s). 2. The effective shear area of reinforced concrete shear walls on each orthogonal axis shall be calculated by passing a horizontal plane through each story level. The height of the plane shall be that height where the area of the shear walls is a minimum. 3. The reinforced concrete elements shall have no visible deterioration of concrete or reinforcement. 4. The vertical elements in the lateral-load-resisting system shall not have significant strength discontinuities; the story strength in any story shall not be less than ninety percent (90%) of the strength of the story above. 5. The lateral-force-resisting elements in all story levels shall form a system that is not subject to significant torsion. Significant torsion is the condition where the distance between the story center of rigidity and the story center of mass is greater than twenty percent (20%) of the width of the structure in the corresponding plan dimension. 6. The minimum ratio of area of reinforcement to gross area of wall in existing reinforced concrete shear walls shall be 0.0015 in both the vertical and horizontal direction or the minimum ratio of axial reinforcement in the columns of frames containing infills shall be 0.01. 7. The ratio of total height to base length of cantilevered or coupled shear walls shall be two (2) or less. The ratio of clear height to in-plane depth of piers in a shear wall shall be two (2) or less. Shear walls or piers having a height to in-plane depth ratio greater than two (2) shall be given an effective shear area of one-half (½) their area. 8. All concrete frames with infilled panels conforming to Subsection 18.71.080.B.1 above shall have total height to base length ratios of two (2) to one (1) or less. C. Analysis procedure. 1. General. Supplemental elements may be added to the existing building to bring the structure into conformance with Subsection 18.71.090.B. 2. Seismic loading. The seismic loading shall be calculated by Subsection 18.71.070.B. The loading of each story level shall be calculated by Formula (71-6) of Subsection 18.71.070.D. 3. Relative rigidities. The relative rigidity of reinforced concrete shear walls may be based on the stiffness of uncracked sections. The relative rigidity of infill panels may be calculated using a common modulus of elasticity. Use of a combination of infills and reinforced concrete or masonry shear walls on any orthogonal axis is prohibited. 4. Required calculations. The calculations may be limited to computation of loads on the reinforced concrete shear walls or infilled frame panels that comply with Subsection 18.71.080.B and computation of the drag and tie forces that develop a complete load path. The loads shall include torsional effects. D. Required strength of systems and elements. 1. The capacity of all parts of the structure shall exceed the demand calculated by use of the loading specified in Section 18.71.070. 2. The strength of infilled frame systems used for lateral load resistance in this section shall be calculated using only the infilled frames that conform to Subsection 18.71.080.B.1. E. Shear stress limit. 1. The maximum horizontal shear stress in new and existing reinforced concrete shear walls shall not exceed two (f'c)1/2. For the purpose of this chapter, the horizontal shear stress may be taken as eighty (80) psi without testing as required by Subsection 18.71.060.F.1. 2. The in-plane shear stress in any masonry infilled panel shall not exceed thirty (30) psi. The calculation of shear stresses shall use net section area and only the area of the infilled masonry. EXCEPTION: The in-plane strength of an infill panel without openings may be calculated by procedures described in published research that were verified by experimental testing and approved by the Building Official.

(ORD-25-0019 § 1(Exh. A), 2025; ORD-22-0033 § 1(Exh. A), 2022; ORD-19-0031 § 1(Exh. A), 2019; ORD-16-0026 § 1(Exh. A), 2016)

Ask a question about Long Beach law

Corpus searches the Long Beach sections it holds and shows the ones that match, with their citations. Free, no sign-in.