§ 200 — Examination and licensing of stationary engineers and process steam boiler operators

Tulsa Revised Ordinances (Supp. No. 3, Update 2: codified through Ordinance No. 25794, passed May 13, 2026) · Tulsa Revised Ordinances tit. 59, § 200

Corpus is an independent public-information project, not the official City of Tulsa website. Stable reference: corpuslaw.us/code/8ce10194-f668-41e2-903a-0a581abea307

Section 200. - Examination and licensing of stationary engineers and process steam boiler operators.

A. Examination of Stationary Engineers; Qualifications. The Code Official shall approve all eligible Stationary Engineer and Process Steam Boiler Operator applicants. Examinations shall be appropriate to the license sought and shall reflect the knowledge and experience required to perform the work of the particular class. The examination for Process Steam Boiler Operators shall be limited to questions on the safe operating practices of process steam boilers. B. Examination Fees. Examinations for each class of stationary engineer license shall be prepared by an independent testing agency. C. Experience. Applicants for the following classes of licenses shall have the minimum experience designated for such class of license as follows: 1. First Class Engineer's License. All applicants for a First Class Engineer's License shall: a. Have at least three (3) years' experience in the operation or assisting in the operation of boilers exceeding fifteen (15) psig steam or one hundred sixty (160) psig water pressure or 250° Fahrenheit water temperature and refrigeration or air conditioning units exceeding one hundred fifty (150) tons; or b. Be a currently-licensed Mechanical Journeyman/Contractor who has had at least one (1) year of experience operating or assisting in the operation of the equipment described in Subsection 200.C.1.a, above; or worked for a Mechanical Contractor for at least three (3) consecutive years installing the equipment described in Subsection 200.C.1.a, above; or c. Have a First Class Limited License and at least three (3) years' experience operating or assisting in the operation of the equipment described in Subsection 200.C.1.a, above; or have a First Class Limited License, having held such license for at least one (1) year and a certificate from an approved school certifying that the applicant has completed a City of Tulsa, Inspections Department, approved course covering the operation of chillers and boilers, and at least one (1) year of experience in the operation of the equipment described in Subsection 200.C.1.a, above; or d. Be a currently-licensed Unlimited Mechanical Journeyman/Contractor in the state of Oklahoma who has a certificate from an approved school certifying that the applicant has completed a City of Tulsa, Inspections Department, approved course covering the operation of chillers and boilers, and at least one (1) year of experience in the operation of the equipment described in Subsection 200.C.1.a, above. 2. First Class Limited Engineer's License. All applicants for a First Class Limited Engineer's License shall: a. Have at least one (1) year of experience in the operation or assisting in the operation of low or high pressure boilers and at least three (3) years' experience in the operation or assisting in the operation of refrigeration or air conditioning units exceeding one hundred fifty (150) tons; or b. Be a currently-licensed Unlimited Mechanical Journeyman/Contractor in the state of Oklahoma who has had at least six (6) months of experience operating or assisting in the operation of low-pressure boilers with an operating temperature of less than 250° Fahrenheit and subject to pressure not exceeding fifteen (15) psig steam or one hundred sixty (160) psig water, and six (6) months of experience in the operation of refrigeration or air conditioning units exceeding one hundred fifty (150) tons, including all related pumps and apparatus, and who has a certificate from an approved school certifying that the applicant has completed a City of Tulsa, Inspections Department, approved course covering the operation of chillers and boilers. 3. Third Class Engineer's License. All applicants for a Third Class Engineer's License shall have at least one (1) years' experience in the operation or assisting in the operation of low or high pressure boilers. 4. Steam Special Engineer's License. All applicants for a Steam Special Engineer's License shall have a least three (3) years' experience in the operation or assisting in the operation of boilers exceeding fifteen (15) psig steam or one hundred sixty (160) psig water pressure. 5. Refrigeration Special Engineer's License. All applicants for a Refrigeration Special Engineer's License shall have at least three (3) years' experience in the operation or assisting in the operation of refrigeration or air conditioning units exceeding one hundred fifty (150) tons. 6. Process Steam Boiler Operator's License. All applicants for a Process Steam Boiler Operator's License shall pass a written examination, and: a. Have a minimum of three (3) months' experience in the operation or assisting in the operation of Process Steam Boilers of over ten (10) horsepower (334,750 BTU/Hour) input; or b. Have successfully completed a short course approved by the Code Official on the safe and proper operating practices for high pressure steam process application boilers. When the operating experience of applicants for the Process Steam Boiler Operator's license is limited to process steam boilers of fifty (50) horsepower (1,673,750 BTU/Hour) input or less and subject to an operating pressure of one hundred fifty (150) psig or less, that experience can only be used toward the experience required for a Third Class license. All experience required for any of the aforementioned classes of license defined in this section and so claimed by an applicant for such class of license shall be proven by a notarized certification from former and present employers concerning the examinee's experience and qualifications. Only experience on the equipment itemized in Section 201 of this Code shall be considered. D. Retesting. An applicant shall be permitted to retest in accordance with the following: Retesting: | The next testing date of the month following the failed test. E. Issuance of Certificates of Competency. Stationary Engineer applicants and Process Steam Boiler Operator applicants receiving a grade of seventy percent (70%) or higher on a required written examination shall be issued a Certificate of Competency. All Certificates of Competency shall display the date of passage of the examination or, if issued without examination as provided in this chapter, the basis for the applicant's qualification. Such certificates shall be consecutively numbered and the Office of Mechanical Inspection shall keep a record of all certificates issued. Should a certificate be lost or destroyed, a duplicate may be obtained under a new registration number by submitting a signed, written request and payment of a replacement fee in accordance with the fee schedule in Title 49, Tulsa Revised Ordinances. Once replaced, the certificate which was lost or destroyed and its registration number shall be invalid. F. Issuance and Renewal of Stationary Engineer and Process Steam Boiler Operator Licenses. Every holder of a current Stationary Engineer or Process Steam Boiler Operator Certificate of Competency shall be issued an annual license appropriate to such certificate by the Code Official upon payment of a license fee in accordance with the fee schedule in Title 49, Tulsa Revised Ordinances. G. Annual License Registration. All Stationary Engineer and Process Steam Boiler Operator licenses shall expire on December 31 and shall be renewed annually. Failure to renew within thirty (30) days of expiration shall subject the former licensee to a penalty fee in accordance with the fee schedule in Title 49, Tulsa Revised Ordinances, per month, until renewal. When any operator's license has been expired for one (1) year or more, the license holder shall retest in accordance with section 200.E. H. Stationary Engineer License and Process Steam Boiler Operator Classifications Established and Work for Which Qualified Defined. Stationary Engineer and Process Steam Boiler Operator licenses shall be issued to qualified applicants divided into the following categories: 1. First Class Engineer's License. Any person holding a First Class Engineer's License shall be qualified to operate and maintain all steam generating boilers, pressure vessels, super heaters, refrigeration plants, and air conditioning units of unlimited tonnage, horsepower, and pressures, and all of their related pumps and apparatus. 2. First Class Limited Engineer's License. Any person holding a First Class Limited License shall be qualified to operate and maintain all boilers with an operating temperature of less than 250° F. and subject to a pressure not exceeding 15 psig steam or 160 psig water and refrigeration and air conditioning units of unlimited tonnage including all related pumps and apparatus. 3. Third Class Engineer's License. Any person holding a Third Class Engineer's License shall be qualified to operate and maintain heating boilers with an operating temperature of less than 250° F. and subject to a pressure not to exceed 15 psig steam or 160 psig water and all related pumps and apparatus. 4. Steam Special License. Any person holding a Steam Special License may operate and maintain all boilers, engines, pumps, and related apparatus of unlimited size and pressure. 5. Refrigeration Special License. Any person holding a Refrigeration Special License may operate and maintain refrigeration plants and units of unlimited tonnage or horsepower. 6. Process Steam Boiler Operator. Any person holding a Process Steam Boiler Operator license may operate high pressure process steam boilers of fifty (50) horsepower (1,673,750 BTU/Hour) input or less and subject to an operating pressure not to exceed 150 psig. Seventy-five percent (75%) of the total boiler capacity must be used for the process system operation. I. Display of Certificates and Licenses Required. Licensees shall keep Certificates of Competency and current licenses displayed at all times in the place where they are employed so that same may be readily seen. In case a copy should be used, it must show the address where the original is displayed. J. Revocation and Suspension of Stationary Engineer and Process Steam Boiler Operator Licenses and Certificates of Competency. Subject to the procedures governing the Board of Appeals as established by Title 51, Chapter 1, Tulsa Revised Ordinances, Stationary Engineer and Process Steam Boiler Operator Certificates of Competency or Stationary Engineer and Process Steam Boiler Operator Licenses may be denied, revoked, suspended, or canceled by the Board for incompetence, gross carelessness in the maintenance or operation of equipment, falsification of a registration document or intoxication while on duty or as otherwise authorized pursuant to Title 51, Chapter 1, Tulsa Revised Ordinances. K. Appeals to City Council. Any person aggrieved by any decision of the Board shall have a right of appeal to the City Council in accordance with the procedures in Title 51, Chapter 1, Tulsa Revised Ordinances.

(Ord. No. 23436, § 1, 2-11-2016; Ord. No. 24151, § 1, 6-26-2019; Ord. No. 24894, § 1, 8-24-2022; Ord. No. 25374, §§ 1—3, 7-31-2024)

Ask a question about Tulsa law

Corpus searches the Tulsa sections it holds and shows the ones that match, with their citations. Free, no sign-in.