18.68.023 - General requirements.

A. General. All buildings shall have a seismic resisting system conforming with UBC Section 2303(b), except as modified by this chapter. B. Alterations and repairs. Alterations and repairs required to meet the provisions of this chapter shall comply with all other applicable requirements of this title unless specifically provided for in this chapter. C. Requirements for plans. The following construction information shall be included in the plans required by this chapter: 1. Dimensioned floor and roof plans showing existing walls and the size and spacing of floor and roof framing members and sheathing materials. The plans shall indicate all existing and new crosswalls and their materials of construction. The location of the crosswalls and their openings shall be fully dimensioned or drawn to scale on the plans. 2. Dimensioned wall elevations showing openings, piers, wall classes as defined in Subsection 18.68.024.C.3(f), thicknesses, heights, wall shear test locations, and cracks or damaged portions requiring repairs. The general condition of the mortar joints shall be noted and if and where the joints require pointing. Where the exterior face is veneer, the type of veneer, its thickness and its bonding and/or ties to the structural wall masonry shall also be reported. 3. The type of interior wall and ceiling surfaces. 4. The extent and type of existing wall anchorage to floors and roof when utilized in the design. 5. The extent and type of parapet corrections which were previously performed, if any. 6. Repair details, if any, of cracked or damaged unreinforced masonry walls required to resist forces specified in this chapter. 7. All other plans, sections, and details necessary to delineate required retrofit construction including those items in Section 18.68.028.

(ORD-25-0019 § 1(Exh. A), 2025; ORD-22-0033 § 1(Exh. A), 2022; ORD-19-0031 § 1(Exh. A), 2019; ORD-16-0026 § 1(Exh. A), 2016)

Ask a question about Long Beach law

Corpus searches the Long Beach sections it holds and shows the ones that match, with their citations. Free, no sign-in.