Sec. 49-823. - Hub and spigot cast-iron soil pipe.
(a) Pipe and fittings shall be tar-coated, conform to ASTM Standard A74-13 and third party certified in accordance with Annex A1 of ASTM A74. (b) Support. (1) Above ground pipe and fittings: (i) Horizontal pipe: All horizontal pipes shall be supported at no more than five-foot intervals or at each bell with no more than ten-foot intervals. Supports shall be placed at the joint where possible and shall be adequate to maintain alignment and prevent sagging. (See Figure 49-823 (b)(1)(i).) When installed with compression gaskets, the requirements for sway bracing and blocking shall be as required for hubless cast iron. (See section 49-822.) (ii) Vertical pipe: All vertical pipe shall be secured at no more than 12-foot intervals to ensure system alignment and adequate support for the pipe weight and its contents. In multi-story structures, floor clamps (also known as friction clamps), are required for vertical piping at each floor. (See Figure 823(b)(1)(ii).) (c) Horizontal underground pipe: (1) Bedding: (i) The entire length of the pipe shall be continuously supported on stable grade. (ii) Bedding material may consist of dirt, sand, gravel, or crushed rock. Backfill and bedding material shall not exceed 1½-inches in diameter. No frozen fill material is acceptable. (iii) Pipe shall not be installed directly on mud, muck, standing water, or frozen ground. If such an unstable condition exists, the trench shall be over-excavated at least six inches and bedding material as listed above other than dirt shall be placed in the trench to support the entire pipe length. (d) Joints shall be made as follows: (1) Lead and oakum. (i) After properly cleaning the hub and the spigot end of the pipe or fitting, oakum shall be placed in the joint and packed using a packing iron and hammered until it forms a uniform surface, one inch from the top of the hub. (ii) Pour molten lead into the joint at one spot between the hub and spigot in one continuous pour until it arches slightly above the top of the hub. (iii) When the lead has cooled, caulk the joint on the inside and then the outside edges using a 16-ounce ball peen hammer and appropriate caulking irons. (iv) Caulking lead shall conform to CS94041 or Lead Industries Association standards. (2) Compression joints. (i) When using cut pipe, the sharp edge must be removed before joining. (ii) After properly cleaning the hub and spigot, insert the gasket into the hub making sure the retaining flange or collar of the gasket is adjacent to the face of the hub. (iii) After using a commercial lubricant applied only on the inside of the gasket (unless the pipe manufacturer also recommends lubricating the spigot of the pipe or fitting), align the spigot and hub in a straight line and force the spigot end of the pipe or fitting into the gasket according to the manufacturer's recommendation. (iv) Gaskets should be stored in a clean, dry area, in an un-deformed condition away from excessive heat. (v) All changes of direction should be restrained. (vi) Material for compression gaskets shall conform to ASTM C-564. (vii) May be used for the final connection for roof drains, floor drains, shower drains and closet flanges only.
(Ord. No. 40524, § 1, 10-20-15)
Ask a question about Omaha law
Corpus searches the Omaha sections it holds and shows the ones that match, with their citations. Free, no sign-in.