§ 223-5 — Definitions
Milwaukee Code of Ordinances (Volumes 1-3 revised through Common Council action of Sept. 22, 2026) · Milwaukee Code of Ordinances § 223-5
Corpus is an independent public-information project, not the official City of Milwaukee website. Stable reference: corpuslaw.us/code/8f2dcf37-5550-41c8-a368-aeb6e86c1336
223-5. Definitions.
In this chapter: 1. AUTHORIZED INSPECTION AGENCY means either of the following: a. An inspection agency as outlined in ANSI/NB-369 and whose inspectors hold a valid certificate as issued by the state of Wisconsin in accordance with s. SPS 305.60, Wis. Adm. Code, as amended. b. An individual who holds a valid certificate as issued by the state of Wisconsin in accordance with s. SPS 305.60, Wis. Adm. Code, as amended, and who provides the department annually with proof of general liability and property damage insurance in the sum of $1,000,000 with the city of Milwaukee as an additional insured, and continuing education and training as outlined in the ANSI/NB-369 series code. 2. BOILER HORSEPOWER (BHP) means a gross boiler output of 33,478 Btu per hour or evaporation of 34.5 pounds of water from and at 212 degrees Fahrenheit per hour, whichever is greater. For electric boilers, one boiler horsepower shall be considered equivalent to an input of 10 kilowatts. 3. CONTROL EQUIPMENT means any electrical, mechanical, pneumatic or hydraulic devices or systems that can be used to manually or automatically control the operating conditions of a boiler, turbine or engine. 4. FIRED PRESSURE VESSEL means any vessel in which steam or other vapor is generated, but not withdrawn for external use; or pressure parts subject to direct firing from the combustion of fuels, or electricity, and which are not within the scope of American society of mechanical engineers (ASME) sections I, III or IV. 5. FIRST CLASS PLANT means any boiler plant which contains a high pressure steam boiler or boilers with a total capacity of more than 600 boiler horsepower output, as rated by boiler manufacturer rating or Wisconsin state code. 6. FOURTH CLASS PLANT means any boiler plant which contains low pressure boilers with a total capacity of more than 150 BHP, or any high pressure steam boiler or boilers with a total capacity not greater than 110 BHP, as rated by boiler manufacturer rating, or Wisconsin state code, and which does not contain any steam engines or turbines except boiler auxiliaries. 7. HIGH PRESSURE BOILER means any boiler on which the safety valve or valves are set to release at a gage pressure greater than 15 pounds per square inch. 8. LOW PRESSURE BOILER means any boiler on which the safety valve or valves are set to release at a gage pressure of 15 pounds per square inch or less. 9. LOW PRESSURE PLANT means any boiler plant which contains one or more low pressure steam boilers with a total capacity of more than 30 BHP but not greater than 150 BHP output, as rated by boiler manufacturer rating or Wisconsin state code. 10. MONITOR EQUIPMENT means any electrical, mechanical, pneumatic or hydraulic devices or systems which are used to provide a visual display of boiler, turbine, or engine operating conditions and which are located in an approved location. All monitored functions shall have associated audible and visual alarm systems to indicate unsafe conditions. 11. REPAIR means any work necessary to restore a boiler, pressure vessel or power piping to a safe operating condition. 12. SECOND CLASS PLANT means any boiler plant which contains a high pressure steam boiler or boilers with a total capacity of more than 400 but not greater than 600 BHP output, as rated by boiler manufacturer rating or Wisconsin state code. 13. STEAM ENGINE AND TURBINE means any engine, turbine or other prime mover which uses steam as the motive power. 14. THIRD CLASS PLANT means any boiler plant which contains a high pressure steam boiler or boilers with a total capacity of 110 BHP but not greater than 400 BHP, as rated by boiler manufacturer rating or Wisconsin state code, and which contains steam engines or turbines other than boiler auxiliaries. 15. UNFIRED PRESSURE VESSEL means a vessel in which pressure is obtained from an external source or from an indirect application of heat. Electric boilers shall be considered to be fired pressure vessels. 16. WISCONSIN PERMIT TO OPERATE means the permit issued by the Wisconsin department of safety and professional services, as described in ch. SPS 341, Wis. Adm. Code, as amended.
Ask a question about Milwaukee law
Corpus searches the Milwaukee sections it holds and shows the ones that match, with their citations. Free, no sign-in.
