For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 600.015 — Willamette Greenway development permit

Salem Revised Code, City of Salem, Oregon (Supp. No. 26: codified through Ordinance No. 10-26, adopted August 10, 2026) · Salem Revised Code § 600.015

Corpus is an independent public-information project, not the official City of Salem website. Stable reference: corpuslaw.us/code/94b71a49-8068-4101-a7c3-583d20cfbe59

Sec. 600.015. - Willamette Greenway development permit.

(a) Applicability. (1) Except as provided under subsection (a)(2) of this section, no intensification, change of use, or development within the Willamette Greenway Overlay Zone shall occur unless a greenway development permit has been issued pursuant to this chapter. (2) Exceptions. A greenway development permit is not required for: (A) Maintenance of scenic easements acquired under ORS 390.368; (B) Addition or modification of existing utility lines, wires, fixtures, equipment, circuits, appliances, and conductors by public or municipal utilities; (C) Flood emergency procedures, and maintenance and repair of existing flood control facilities; (D) Placement of signs, markers, aids, etc., by a public agency to serve the public; (E) Residential accessory uses, such as lawns, gardens, and play areas in existence prior to June 9, 2004; (F) Landscaping undertaken in accordance with this chapter; (G) Storage of material or equipment associated with uses permitted outright within RA (Residential Agricultural) and RS (Single Family Residential) Zones, provided that the storage complies with all applicable provisions of the UDC; (H) Seasonal increases in gravel operations, subject to any conditions imposed by law, ordinance, or conditional use approval; (I) Improvement of a public park, in accordance with an officially approved master plan and the setback requirements of this chapter; (J) Alterations of buildings or accessory structures which do not increase the size or alter the configuration of the building or accessory structure footprint; (K) Activities allowed within the underlying zone which are usual and necessary for the use and enjoyment of an existing residence, including the modification of existing accessory structures; (L) Ordinary maintenance and repair of buildings, structures, parking lots, or other site improvements that were in existence prior to June 9, 2004; (M) Removal of nuisance or invasive non-native vegetation identified on the City of Salem Plant List, and consistent with erosion prevention and sediment control standards in SRC chapter 75; or (N) Development of a Willamette Greenway trail or access paths, provided that all development and management standards meet the requirements of adopted parks management plans. (b) Classes. (1) Class 1 greenway development permit. A Class 1 greenway development permit is a permit for any intensification, development, or change of use occurring within the Willamette Greenway, but outside of the compatibility review boundary. (2) Class 2 greenway development permit. A Class 2 greenway development permit is a permit for any intensification, development, or change of use occurring inside of the compatibility review boundary. (c) Procedure type. (1) Class 1 greenway development permit. A Class 1 greenway development permit is processed as a Type II procedure under SRC chapter 300. (2) Class 2 greenway development permit. A Class 2 greenway development permit is processed as a Type III procedure under SRC chapter 300. (d) Submittal requirements. In addition to the submittal requirements under SRC chapter 300, an application for a Class 1 or Class 2 greenway development permit shall include the following: (1) An existing conditions plan, of a size and form and in the number of copies meeting the standards established by the Director, containing the following information: (A) The total site area, dimensions, and orientation relative to north; (B) Site topography shown at five-foot contour intervals, or two-foot contour intervals for areas within a floodplain; (C) The location of existing buildings, accessory structures, and other improvements on the site, including parking areas, loading areas, driveways and driveway approaches, fences, and walls, and whether they are to be removed; (D) The location of the 100 year floodplain, if applicable; and (E) The location of drainage patterns and drainage courses, if applicable. (2) A site plan, of a size and form and in the number of copies meeting the standards established by the Director, containing the following information: (A) The total site area, dimensions, and orientation relative to north; (B) The use, location, distance to property lines, and height of all proposed buildings and accessory structures; (C) The location, distance to property lines, and layout of all proposed parking areas, including the size, number, and dimensions of proposed spaces; (D) The location of all proposed driveways and driveway approaches; (E) The location and square footage of all proposed landscaping; (F) The location, height, and material of all proposed fences, walls, berms, and other proposed screening; (G) The location of all trees and vegetation required to be protected pursuant to SRC chapter 808; (H) The location of the riparian buffer required under SRC 600.025(c)(2); (I) The location of the ordinary low water line and the ordinary high water line; and (J) The location of proposed pedestrian circulation areas. (3) Identification of the color and exterior surface materials of all proposed buildings, structures, fences, walls, and mechanical equipment. (4) A mitigation plan containing the following: (A) Identification of a wider riparian buffer, in compliance with the standards set forth in SRC 600.025(c)(3)(A), if a greater riparian buffer is chosen as a mitigation measure under SRC 600.025(c)(3). (B) An enhancement plan, in accordance with the Willamette Greenway Riparian Buffer Enhancement Guide, if riparian buffer enhancement is chosen as a mitigation measure under SRC 600.025(c)(3). (C) An off-street parking stormwater management plan, in compliance with the standards set forth in SRC 600.025(c)(3)(C), if off-street parking design standards for stormwater quantity and quality are chosen as a mitigation measure under SRC 600.025(c)(3). (D) A tree planting plan, in compliance with the standards set forth in SRC 600.025(c)(3)(D) if tree planting for stormwater management is chosen as a mitigation measure under SRC 600.025(c)(3). (E) The location and design of proposed alternative paving techniques, in accordance with the standards set forth in SRC 600.025(c)(3)(E), if utilization of alternative paving techniques is chosen as a mitigation measure under SRC 600.025(c)(3). (5) A report by a certified engineering geologist or geotechnical engineer demonstrating that the standards specified in SRC 600.025(a)(2) have been met. (6) A report by a registered professional engineer detailing the hydraulic and flood carrying capacity of the river. (e) Criteria. (1) Class 1 greenway development permit. An application for a Class 1 greenway development permit shall be granted if all of the following criteria are met: (A) The proposed intensification, development, or change of use is consistent with: (i) The Willamette River Greenway Plan; (ii) The Willamette Greenway Riparian Buffer Enhancement Guide; (iii) The applicable standards of this chapter; and (iv) Where applicable, the stormwater runoff water quality standards adopted and administered by the Public Works Department. (B) The proposed intensification, development, or change of use complies with all applicable development standards in the UDC. (2) Class 2 greenway development permit. An application for a Class 2 greenway development permit shall be granted if all of the following criteria are met: (A) The proposed intensification, development, or change of use is consistent with: (i) The Willamette River Greenway Plan; (ii) The Willamette Greenway Riparian Buffer Enhancement Guide; (iii) The applicable standards of this chapter; and (iv) Where applicable, the stormwater runoff water quality standards adopted and administered by the Public Works Department. (B) The proposed intensification, development, or change of use complies with all applicable development standards in the UDC. (C) The proposed intensification, development, or change of use will, to the greatest extent possible, provide the maximum possible landscaped area, open space, or vegetation. (f) Conditions of approval. (1) Conditions may be imposed on any greenway development permit necessary to insure that proposed intensification, development, or change of use complies with the Willamette River Greenway Plan and the purpose of this chapter, and preserves and enhances the natural, scenic, historic, and recreational qualities of the Willamette River Greenway. (2) In addition to any conditions imposed under subsection (f)(1) of this section, every greenway development permit shall include the following conditions: (A) Prior to any excavation, grading, or construction, a survey map, certified by a licensed professional land surveyor, shall be submitted to the Director showing the Willamette Greenway Boundary and its relationship to the site and survey monuments thereon. (B) Prior to any excavation, grading, or construction, plans for removal and replacement of any native vegetation shall be submitted to and approved by the Director.

(Prior Code, § 600.015; Ord. No. 31-13)

Ask a question about Salem law

Corpus searches the Salem sections it holds and shows the ones that match, with their citations. Free, no sign-in.