Sec. 12.26.040. - Application and review process.
(a) Pre-application option.
(1) At the request of the applicant, a non-mandatory pre-application process can be implemented as agreed by the city and licensee and/or applicant.
(2) Pre-application submittals are limited to a maximum total batch size of individual locations designated by the city engineer set forth in the pre-application.
(3) Pre-application locations are reserved on a first come first serve basis and are reserved for a maximum of 90 days and are locked in on submission of the final application.
(b) Final Application Submittal.
(1) The following information must be provided for all submittals:
(i) A small cell permit fee for each proposed location as established by city council resolution.
(ii) Engineered site plans drawn to scale and prepared, signed and certified by a Nevada-licensed engineer. Plans must include:
a. Street names, parcel numbers, and the addresses of all properties surrounding the proposed facility location.
b. Elevations and dimensions for before and after the proposed construction conditions with all height and width measurements called out.
c. Details of all proposed equipment, antennas, power cut off switches, electric meters, and cabinets.
d. All proposed utility runs and points of contact.
e. Easement locations for access and utilities.
f. Location of surface improvements, i.e. roadways, curb and gutter, sidewalk, pedestrian ramps, signs, poles, landscaping, etc.
g. Location of all subsurface improvements in the immediate area (approximate 25 foot radius) which may be impacted by the proposed work.
h. Location and detail of the placard and its placement.
i. Locations for all proposed electrical meters.
(iii) Photo simulations of the proposed location showing a post installation condition of all proposed equipment, antenna, meter sets, vaults, cabinets, from a reasonable line of sight as viewed from the public street.
(iv) If required, a letter of authorization (LOA) from the pole owner.
(v) When connecting electrical equipment, a certified engineer's report demonstrating the power requirements of the proposed equipment are adequately supported by the existing infrastructure.
(vi) For locations requiring building permits (i.e. new meter sets), copies of each building permit and the address assigned to the meter must be provided with the submittal package.
(vii) The issued encroachment and excavation permits pursuant to RMC 6.11 and 12.08.
(viii) Evidence of compliance with applicable federal radio frequency (RF) exposure standards, a report prepared by a licensed engineer that certifies that the proposed small cell complies with such federal standards and a report that the proposed small cell will not interfere with any existing RF signal or equipment operations.
(ix) An engineer's report demonstrating that the proposed noise level of the equipment associated with a small cell will be within the noise standards of RMC, as amended. If the proposed equipment is non-noise generating, a statement can be included on the construction plans in lieu of the report.
(c) Review and timelines.
(1) Applications are reviewed by the public works department staff.
(2) Applications to collocate using an existing structure will be reviewed within 60 days.
(3) Applications to deploy using a new structure will be reviewed within 90 days.
(4) Unless otherwise agreed to in writing, within ten days after submission of the initial application, the city shall notify the applicant in writing if the application is materially incomplete and said notice will specifically identify the missing documents and/or information required by this chapter. During this time, no shot clock applies.
(5) Unless otherwise agreed to in writing, within ten days after submission of the resubmitted application, the city shall notify the applicant in writing if the resubmitted application is still incomplete and said notice will specifically identity the missing documents and/or information required by this chapter. The shot clock is paused until a subsequent application is submitted.
(Ord. No. 6508, § 1, 4-10-19)