§ 18.71.090 — Minimum requirements for a limited structural analysis
Long Beach Municipal Code (Supp. No. 53, Update 1: codified through Ordinance No. ORD-26-0027, enacted October 13, 2026) · Long Beach Municipal Code § 18.71.090
Corpus is an independent public-information project, not the official City of Long Beach website. Stable reference: corpuslaw.us/code/a033ac34-6bb6-4a07-9656-6146bf8ec5e1
18.71.090 - Minimum requirements for a limited structural analysis.
A. General. Structures conforming to the requirements of this section may be shown to be in conformance with this chapter by submission of the report described in this section. B. Required features of the building. The building shall conform to all of the following features or the building shall be analyzed as prescribed by Subsection 18.71.050.D. 1. The lateral-load-resisting elements of the building shall be reinforced concrete shear walls. 2. The minimum ratio of area of reinforcement to gross area of the wall shall be 0.0015 in both the vertical and horizontal directions. 3. The reinforced concrete elements shall have no visible deterioration of concrete or reinforcement. 4. The area of concrete shear walls on each orthogonal axis at the first floor level shall be 1.5% of the area of the first floor of the building, where n is the number of floor and roof levels. 5. The area of the shear walls in all stories above the first floor shall not be more than one hundred percent (100%) or less than eighty percent (80%) of the area of shear walls at the first floor. 6. The concrete shear walls in all stories above the first floor shall be directly above the shear walls at the first floor which are used to calculate the percent of shear wall area to floor area. 7. The wall area must be uniformly distributed such that at least eighty percent (80%) of the wall area used in the calculation is symmetrically placed about the center of the building. 8. The area of the shear walls on each orthogonal axis shall be calculated by passing a horizontal plane through the first story level. The height of the plane shall be that height where the area of the shear walls is a minimum. 9. The ratio of total height to base width of cantilevered or coupled shear walls shall be two (2) or less. The ratio of the clear height to in-plane depth of piers in a shear wall shall be two (2) or less. Shear walls or piers having a height to depth ratio greater than two (2) shall be given an effective area of one-half (½) of their area. C. Information required in the report. 1. The report shall include data, sketches, plans and calculations that show conformance with the features given in this section. 2. The registered design professional of record shall meet with the representative of the Department at the site to review the report.
(ORD-25-0019 § 1(Exh. A), 2025)
Ask a question about Long Beach law
Corpus searches the Long Beach sections it holds and shows the ones that match, with their citations. Free, no sign-in.