Sec. 15-30. - Water supply and distribution.
(a) General requirements. An accessible, adequate, safe and potable supply of water shall be provided in each mobile home park. Where a public supply of water of satisfactory quantity, quality, and pressure is available at the site or at the boundary of the site, connection shall be made thereto and its supply used exclusively. When a satisfactory public water supply is not available, a private water supply system may be developed and used as approved by the county health officer. (b) Source and volume of supply. (1) The water supply shall be capable of supplying a minimum of one hundred fifty (150) gallons per day per mobile home. (2) Every well or suction line of the water supply system shall comply with appropriate regulations of the county health officer. (3) No well casings, pumping machinery or suction pipes shall be placed in any pit, room or space extending below ground level or in any room or space above ground which is walled in or otherwise enclosed, unless such rooms, whether above or below ground, have degree drainage by gravity to the surface of the ground. (4) The treatment of a private water supply shall be in accordance with applicable laws and regulations. (c) Water storage facilities. All water storage reservoirs shall be covered, watertight and constructed of impervious material. Overflows and vents of such reservoirs shall be effectively screened. Manholes shall be constructed with overlapping covers, so as to prevent the entrance of contaminated material. Reservoir overflow pipes shall discharge through an acceptable air gap. (d) Water distribution system. (1) All water piping, fixtures and other equipment shall be constructed and maintained in accordance with state and local regulations and requirements, including specifically Section 603 of the city fire prevention code. If the mobile home park is served by a public water department or authority, the water supply system shall conform to all standards and requirements of that department or authority, as well as the city plumbing code. Mobile home parks served by a private water supply shall conform to all requirements and standards of the city plumbing code, as well as any requirements imposed by the county health department. (2) The water piping system shall not be connected with nonpotable or questionable water supplies and shall be protected against the hazards of backflow or back siphonage. (3) The system shall be so designed and maintained as to provide a pressure of not less than twenty (20) pounds and not more than eighty (80) pounds per square inch, under all normal operating conditions at each mobile home stand. Also the system shall be capable of supplying e.g. fifty (50) mobile homes with a demand load of one hundred (100) gpm, one hundred (100) mobile homes with one hundred eighty (180) gpm, and three hundred (300) mobile homes with three hundred seventy (370) gpm. Greater design values may be required when the system is to provide fire hydrants. In such event the water supply system shall permit the operation of a minimum of two (2) one and one-half (1½) inch hose streams. Each of two (2) nozzles, held four (4) feet above the ground, shall deliver at least seventy-five (75) gallons of water per minute at a flowing pressure of at least twenty (20) pounds per square inch at the highest elevation point of the park. (4) Fire hydrants, if provided, shall be located within five hundred (500) feet of any mobile home, service building or other structure in the park. (5) Water mains, if installed parallel to sewer lines, shall be separated, whenever possible, at least ten (10) feet horizontally from any sanitary sewer, storm sewer or sewer manhole. In case of unusual conditions, separation requirements can be waived, provided the sewer is constructed of materials and with joints that are equivalent to water main standards of construction and shall be pressure tested to assure watertightness prior to back filling. (e) Individual water riser pipes and connections. (1) Individual water riser pipes shall be located within the area of the mobile home stand and approximately thirty (30) feet from the front of such stand. (2) Water riser pipes shall extend at least four (4) inches above ground elevation. The pipe diameter shall be at least three-quarters (¾) inch. The water outlet shall be capped when a mobile home does not occupy the lot. (3) Adequate provisions shall be made to prevent freezing of service lines, valves and riser pipes and to protect risers from heaving and throwing actions of ground during freezing weather. Surface drainage shall be diverted from the location of the riser pipe. (4) A shutoff valve below the frost line shall be provided near the water riser pipe on each mobile home lot. (5) Underground stop and waste valves shall not be installed on any water service.
(Code 1962, § 21A-31; 2996, § 6, 10-19-89)
Ask a question about Tuscaloosa law
Corpus searches the Tuscaloosa sections it holds and shows the ones that match, with their citations. Free, no sign-in.