Section 65.070. - Screening.
A. Purpose. Screening requirements are intended to partially or completely shield expressly identified uses and site features from view of abutting streets or other abutting lots.
B. Features required to be screened.
1. General. This subsection establishes screening requirements for several common site features that require visual separation from streets and abutting lots. Other uses, districts, structures and activity areas may also require screening in accordance with other provisions of this zoning code.
2. Dumpsters. All dumpsters must be screened from view of all street rights-of-way and R-zoned property, and AG-R zoned property. Screening of dumpsters located in alley rights-of-way is not required. Dumpsters may be screened from view by a principal structure or by an F1 screening fence or wall in accordance with Subsection 65.070C. When an F1 screening fence or wall encloses a dumpster on four sides, one side of the storage area must be furnished with an opaque, lockable gate kept closed at all times except during waste deposit or collection. The gate must be located and constructed to allow for unobstructed access to each dumpster during collection.
Figure 65-5: Dumpster Screening
[image omitted; see the official code]
3. Mechanical Equipment.
a. Ground-mounted equipment. Mechanical equipment located at ground level, such as heating or cooling equipment, pumps, or generators must be screened from view of the street and any abutting R or AG-R districts by walls, fences or vegetation. Screening must be at least as tall as the tallest part of the equipment required to be screened
Figure 65-6: Screening of Ground-mounted Equipment
[image omitted; see the official code]
b. Roof-mounted equipment. Mechanical equipment placed on roofs must be screened in one of the following ways, if the equipment is within 50 feet of an R or AG-R zoning district:
(1) A parapet along facades facing the R or AG-R district that is as least as tall as the tallest part of the equipment;
(2) A screening fence or wall around the equipment that is as least as tall as the tallest part of the equipment required to be screened; or
(3) An equipment setback from roof edges facing the R or AG-R district by at least 3 feet for each one foot of equipment height.
Figure 65-7: Screening of Roof-mounted Equipment
[image omitted; see the official code]
C. Type of screens.
1. S1, low-profile screen.
a. Purpose. The S1, low-profile screen is intended to help soften visual impacts of certain site features and provide an "urban edge" along lot borders and other site features, while maintaining some visibility of the areas required to be screened.
b. Design. The S1 screen requires shrubs planted to form a continuous visual barrier (hedge) at least three (3) feet in height. A screening wall with a minimum height of two and one-half (2.5) feet and a maximum height of three (3) feet may be substituted for the shrubs. Walls used to satisfy S1 screening requirements must be constructed of brick, stone, cast stone, formed concrete or similar durable, low-maintenance materials.
2. S2, mid-profile screen.
a. Purpose. The S2, mid-profile screen is intended to shield vehicles, headlights, and other elements of drive-throughs from view of abutting streets.
b. Design. The S2 screen requires a low wall or berm, plus shrubs and trees between the wall/berm and the lot line.
(1) Enough shrubs must be planted to form a continuous hedge at least three (3) feet in height. Shrubs must be at least twenty-four (24) inches tall at the time of planting. Up to forty (40) percent of shrubs may be deciduous.
(2) One large tree, as defined in Subsection 65.080B. and listed in the Recommended and Prohibited Tree Species List, is required per twenty-five (25) linear feet of landscaped area. If large trees are not feasible due to the presence of overhead lines or other utility obstructions, as determined by the land use administrator, at least one small tree is required per fifteen (15) linear feet of landscaped area.
(3) A screening wall or earthen berm with a minimum height of three (3) feet and a maximum height of four (4) feet is required along the full length of the interior side of the landscaped area. Walls used to satisfy S2 screening requirements must be constructed of brick, stone, cast stone, formed concrete or similar durable, low-maintenance materials. Plain concrete blocks are not allowed as a screening wall material unless capped and finished with stucco or another decorative material.
3. F1, screening fence or wall.
a. Purpose. An F1 screening fence or wall is required in those instances where a complete visual barrier is needed.
b. Options. F1 screening requirements may be met by either of the following options:
(1) The installation of an opaque fence at least six (6) feet in height and at least one tree per twenty-five (25) linear feet of fence; or
(2) The installation of a masonry wall with a minimum height of six (6) feet.
c. Street setback. When located in the required street setback, required F1 screening fences and walls may not exceed four (4) feet in height.
4. Materials, installation and maintenance. See Section 65.080 and Section 65.090. Any tree planting requirements associated with F1 screens may be satisfied by the installation of new trees or by the preservation of existing trees (see Subsection 65.080B.4. to determine available incentives for preservation of existing trees).
5. Modification of requirements.
a. Applicable screening requirements may be waived or modified through the alternative compliance approval process (see Subsection 65.100D.) or through the special exception approval process when:
(1) Existing features provide a visual screen equivalent to the screening requirements of this section;
(2) The screening requirements cannot be achieved; or
(3) The screening is prohibited by other ordinances or regulations.
b. An extension of time to install required screening may be approved through the special exception approval process when the properties benefited by the screening are undeveloped.
6. Screening or setbacks triggered by proximity to nonresidential areas/features. When a screening wall or fence or setback is required by this zoning code because a use abuts one or more R or AG-R districts, such wall, fence, or setback is not required if the actual use of the abutting R or AG-R district is a freeway, expressway, turnpike, nonresidential use; or a nonresidential development area. This exemption from screening does not apply to junk or salvage yards.
(Ord. No. 24279, §§ 4, 5, 12-11-2019; Ord. No. 24382, §§ 9—12, 6-10-2020; Ord. No. 25656, § 26, 9-10-2025)