Sec. 26-104. - High voltage installations.

(a) High voltage installations for underground services in subdivisions shall consist of a dual feeder service capable of being energized from either end and capable of being sectionalized and insulated at each transformer location. (b) The main distribution point of each end of the dual feeder shall be protected by line class arresters, fused disconnects and approved pothead cable terminations. (c) The cables shall have a metal conduit protection at all points where mechanical damage is likely to occur, and all cables shall conform to all utility department requirements and specifications regarding such metal conduits, and metal conduits shall be installed when required by the inspector of underground utilities. (d) All conduit systems shall be buried at a minimum depth of forty-two (42) inches below finished grade. After excavation the first six (6) inches of refill earth shall be of selected material free of stones and sharp objects. The remainder of the refill may be of the excavated materials. (e) Conduit bends shall not be less than ten (10) times the diameter of the conduit. (f) Terminations within the high voltage chamber of the transformer may be either stress cones or an approved cable termination. (g) Terminations in weathered locations may be only of an approved cable termination. (h) Underground high voltage conduits shall contain a bare soft drawn or medium hard drawn copper cables of the same physical size of the current-carrying cables (i) Underground high voltage cables shall be of the shielded and grounded 15 KV approved type and the shields and grounds shall be securely fastened to the ground network system. (j) Sizing of underground high voltage cables shall be done by the city electrical engineer but in no case shall be smaller than a No. 2 AWG size. (k) All underground direct burial shall be under the strict supervision of the inspector of underground utilities and shall conform to all utility department requirements and be in accordance with the plans and specifications previously submitted therefor by the installer or developer and approved by the assistant city manager - utilities. All underground direct burial of high voltage systems shall be marked aboveground at locations and in the manner directed by the inspector of underground utilities.

(Code 1966, § 25-118)

Ask a question about Denton law

Corpus searches the Denton sections it holds and shows the ones that match, with their citations. Free, no sign-in.