225-4. Drainage of Yard Areas and Roofs.

1. UNDERGROUND DRAINS. All underground drains from roof rainwater leaders, paved areas, yards, courts and subsurface drains shall be mechanically connected to a storm sewer or combined sewer when they are available and abutting the property, except that such drains may discharge in an approved manner into an adjacent lake, river or stream, provided they are not in conflict with the rules of the Milwaukee metropolitan sewerage district. 2. ROOF RAINWATER LEADERS (CONDUCTORS). a. Discharge to Finished Grade; When Permitted. All buildings, including accessory buildings, may discharge roof rainwater leaders, conductors or downspouts to finished grade provided the discharge to finished grade meets all of the following provisions: a-1. The point of discharge shall be a minimum of 2 feet from a basement or a foundation wall or alley property line and 5 feet from all other property lines. a-2. The discharge shall flow parallel to or away from the nearest property line. a-3. The discharge water shall not discharge to a street, alley or other public way. a-4. The discharge water shall not create an icy condition on any pedestrian walkways within or adjacent to the subject premises lot lines. a-5. The downspout hub shall be sealed with a 1" concrete cap or in a manner approved by the commissioner. b. Connection to Combined Sewer Prohibited. b-1. For all residential structures containing 4 or fewer dwelling units that do not have the option of discharging to a storm sewer, and for which discharge to finished grade from roof rainwater leaders, conductors or downspouts of any building, including any accessory building, can meet the provisions of par. a, all roof rainwater leaders, conductors or downspouts shall discharge to the finished grade. b-2. All existing connections to a combined sewer that can meet the provisions of subd. 1 shall be permanently disconnected and sealed in accordance with this section. b-3. Any person violating this regulation shall be subject to penalty pursuant to s. 220-19. c. Connection to Sewer Required. Whenever discharge to finished grade from the roof cannot meet the provisions of par. a, all roof rainwater leaders, conductors or downspouts shall be mechanically connected to the storm sewer or combined sewer, or to an approved storm sewer facility when it is available and abutting the property. This shall include parcels that have access by easement or private roads when the storm sewer is available at the point of access. d. Waiver. Any provision of par. a may be waived by the commissioner if the property owner submits, and the commissioner accepts, plans for a discharge system designed by a registered civil engineer for purposes of complying with the intent of par. a. e. Use as Support Prohibited. No conductor, roof rainwater leader or downspout shall be used as a support for any part of a building, structure or appendage to same. f. Installation and Maintenance. All outside roof leaders (conductors) installed under or in the ground shall be installed as regulated in s. SPS 382.36, Wis. Adm. Code. Conductors shall terminate with an approved pipe above grade. The sheet metal conductors shall be connected and sealed to the pipe in an approved manner. Roof leaders (conductors) connecting to the storm building drain in the basement shall be of an approved pipe material to a point at least 2 feet inside the basement foundation wall. Roof leaders (conductors) shall be maintained in good repair and free of stoppages. g. Discharge into Catch Basin or Sand Interceptor Prohibited. Rainwater leaders in the combined sewer area shall not discharge into a catch basin or sand interceptor. The sewer from the rainwater leader shall bypass the catch basin or sand interceptor and shall have a direct connection to the sewer system. 2.5 RAIN BARRELS. a. Definition. In this subsection, a rain barrel means an above-ground prefabricated storage receptacle with an automatic overflow diversion system that collects and stores storm water runoff from the roof of a structure that would have been otherwise routed into a storm drain. b. Rain Barrels Permitted. Rain barrels shall be permitted provided that the overflow discharge conforms to the provisions of s. 225-4-2-a, or is designed to overflow to a treatment drain or storm water conveyance system. c. Requirements. A rain barrel shall be securely covered, include an inlet screen, have an overflow discharge device sized to adequately convey overflow to the point of discharge and have a convenient and functional means of water withdrawal. 3. NEWLY PAVED AREAS OR PARKING LOTS. a. Storm Sewer Required. As regulated in s. 252-74, storm sewers shall be required for all paved areas except that paved areas for gasoline pumping islands shall be drained to the streets. b. Permeable Paving. The commissioner may allow the use of permeable paving as regulated in s. 252-74. For newly paved areas or parking lots, the storm sewer requirement under this section may be waived by the commissioner if adequate drainage is provided. Perforated underdrain piping shall be required for the full length of all permeable pavement applications greater than 1,000 square feet where permeable pavement is being used in lieu of a catch basin or storm inlet. c. Subsurface Drainage. Subsurface drainage for dewatering parking lots and other areas shall be connected to an approved catch basin before entering a city of Milwaukee sewer. d. Catch Basins and Storm Inlets. A catch basin or storm inlet shall be located so that no point of an impervious paved area is further than 300 feet from a catch basin, storm inlet, trench drain or permeable pavement surface with subsurface drainage. Every catch basin shall be connected to a combined sewer and every storm inlet shall be connected to a storm sewer. e. Trench Drains. Trench drains shall be provided where all or part of the paved area is sloped toward the public right of way. f. Sizing. All sewer lines and drains shall be sized in accordance with the provisions in this code and s. SPS 382.36, Wis. Adm. Code. g. Slope. All paved areas shall be sloped in such a way that there is drainage toward a drain. Flat areas which allow ponding shall not be allowed. All paved areas shall be sloped away from the street or a trench drain shall be provided to prevent drainage onto the street or sidewalk. h. Drainage Systems. Plans for a parking lot requiring a drainage system pursuant to s.252-71 shall be submitted in triplicate to the commissioner of city development. Upon approval of the plans and payment of the fees set forth in s. 200-33, a plumbing permit shall be issued for the drainage system. 4. CATCH BASINS. a. Catch basins shall be constructed in a water-tight and substantial manner of concrete masonry, brick masonry, concrete block masonry, precast reinforced concrete, cast iron, bitumastic enamel coated 12 gauge steel, vitrified clay or other materials approved by the state department safety and professional services. b. Catch basins in the combined sewer area shall be a minimum of 36 inches inside diameter and shall have a minimum depth of 48 inches to the flow or water line. The outlet shall be provided with a cast iron elbow or an inverted wye connection not less than 4 inches inside diameter and shall be submerged not less than 12 inches below the flow or water line and shall terminate not less than 18 inches above the bottom of the catch basin. A cleanout shall be provided in the horizontal pipe. c. The catch basins and storm inlets shall have a fitted removable cover of a thickness and strength to sustain weight or traffic to which it will be subjected. d. Catch basins, retention basins or ponds, underground vaults and filters designed for the management and regulations of storm water pursuant to ch. 120 shall meet the requirements of that chapter and of ss. SPS 382.20, 382.34, and 382.36, Wis. Adm. Code. 5. STORM INLETS. Storm inlets shall be installed as regulated in s. SPS 382.36, Wis. Adm. Code. 6. SEWER FACILITIES. A building shall be deemed to have sewer facilities available if it complies with s. 225-22-2-b. 7. OTHER DRAINAGES. Absorption, permeable paving, natural drainage alley and street drainages are covered in s. 252-71.

Ask a question about Milwaukee law

Corpus searches the Milwaukee sections it holds and shows the ones that match, with their citations. Free, no sign-in.