§ 18.18.080 — Total outdoor light output standards
El Paso City Code (Supp. No. 95, Update 4: codified through Ordinance No. 019889, enacted June 23, 2026) · El Paso City Code § 18.18.080
Corpus is an independent public-information project, not the official City of El Paso website. Stable reference: corpuslaw.us/code/b76735f1-83d7-46ce-a16f-96ee04aa78ec
18.18.080 - Total outdoor light output standards.
Total outdoor light output shall not exceed the limits in Table 18.18.080. Seasonal decorations are not counted toward these limits; lighting used for external illumination of signs is counted, while lighting used for internal illumination of signs is not counted. (The values in this table are the maximum permitted levels and not intended as design standards; design standards shall be the lowest levels that meet the requirements of the task.) Table 18.18.080 Maximum Total Outdoor Light Output Standards Lumen Caps—Initial Lamp Lumens per Net Acre | Lighting Zone E4 | E3(4) | E2(4) | E1 Commercial and Industrial uses (1) Total (full cutoff+ unshielded) | 1,000,000 | 200,000 | 50,000 | 125,000 Unshielded only | 40,000 | 20,000 | 4,000 | 2,000 Residential uses (2,3) Total (full cutoff + unshielded) | 20,000 | 10,000 | 10,000 | 10,000 Unshielded only | 5,000 | 5,000 | 1,000 | 1,000 Notes to Table 18.18.080 1. This refers to all commercial and industrial uses and includes multiple family or apartment uses. 2. This refers to all single-family attached or detached uses. 3. In lighting zones E4-E 1, each residential single-family attached or detached home, duplex, triplex, quadruplex or townhome is allowed up to five thousand five hundred total lumens, or the amount indicated in this table based on the parcel's acreage, whichever is larger. Each is also allowed a maximum of five thousand five hundred lumens of unshielded ("A") lighting, provided Table 18.18.070 allows the lamp's type with "A" shielding. All residential spot or flood lamps permitted are to be aimed no higher than twenty-five degrees from the vertical line between the fixture and the ground when the source is visible from any off-site residential property or public roadway. 4. Public and private schools located in zones E2 and E3 may petition the director for an increase in the lumens per acre cap to the level permitted in zone E4. The director may allow an increase when the school submits an engineered design supporting the need of such increase. 5. For projects using a portion of a parcel, the calculation of the allowable lumen cap shall be based on a project area that includes only the building, parking and landscaping portions of the parcel.
(Ord. 15996 § A (part), 2005) (Ord. 17171, § 7, 8-18-2009)
Ask a question about El Paso law
Corpus searches the El Paso sections it holds and shows the ones that match, with their citations. Free, no sign-in.