Chandler City Code § 52-1 Definitions.
52-1. - Definitions.
Approved: Accepted by the Director of Public Works as meeting an applicable specification stated or cited in this article, or as suitable for the proposed use.
Appurtenances: Items attached to a main structure which enable it to function, but not considered an integral part of it.
Auxiliary water supply: Any water supply on or available to the premises other than the City's approved public potable water supply. These auxiliary waters may include water from another purveyor's public potable water supply or any natural source(s) such as well, spring, river, stream, treated effluent, wastewaters, etc., or "used waters" or "industrial fluids." These waters may be polluted or contaminated or they may be objectionable and constitute an unacceptable water source over which the City does not have sanitary control.
Backflow: The reversal of the normal flow of water caused by either back-pressure or back-siphonage.
Back-pressure: The flow of water or other liquids, mixtures or substances under pressure into the distribution pipes of a potable water supply system from any source or sources other than its intended source.
Back-siphonage: The flow of water or other liquids, mixtures, or other substances into the distribution pipes of a potable water supply system from any source or sources other than its intended source caused by the sudden reduction of pressure in the potable water supply system.
Backflow prevention assembly: A device or means designed to prevent backflow.
A. Air-gap: The unobstructed vertical distance through the free atmosphere between the lowest opening from any pipe or faucet supplying water to a tank, plumbing fixture, or other device and the flood level rim of the vessel. An approved air-gap shall be at least double the diameter of the supply pipe, measured vertically, above the top of the overflow rim of the vessel, and in no case less than one (1) inch.
B. Reduced pressure principle device: An assembly of two (2) independently operating approved check valves with an automatically operating differential relief valve between the two (2) check valves, tightly closing shutoff valves on either side of the check valves, plus properly located test cocks for the testing of the check and relief valves. The entire assembly shall meet the design and performance specifications and approval of a recognized and City-approved testing agency for backflow prevention assemblies. The device shall operate to maintain the pressure in the zone between the two (2) check valves at a level less than the pressure on the public water supply side of the device. At cessation of the normal flow the pressure between the two (2) check valves shall be less than the pressure on the public water supply side of the device. In case of leakage of either of the check valves, the differential relief valve shall operate to maintain the reduced pressure in the zone between the check valves by discharging to the atmosphere. When the inlet pressure is two (2) pounds per square inch or less, the relief valve shall open to the atmosphere. To be approved, these devices must be readily accessible for in-line maintenance and testing and be installed in a location where no part of the device will be submerged. An acceptable method of handling discharge water from the device must be approved by the Director of Public Works.
C. Double check valve assembly: An assembly of two (2) independently operating approved check valves with tightly closing shutoff valves on each end of the check valve. The entire assembly shall meet the design and performance specifications and approval of a recognized and City-approved testing agency for backflow prevention devices. To be approved, these devices must be readily accessible for in-line maintenance and testing.
D. Double check-detector check valve assembly: Means a specially designed assembly composed of a line-size approved double check valve assembly with a specific bypass five-eighths-inch by three-quarter-inch, or three-quarter-inch water meter and a three-quarter-inch approved double check valve assembly. The meter shall register all rates of flow. This assembly shall only be used to protect against a nonhealth hazard (i.e. pollutant).
E. Pressure vacuum breaker assembly: An assembly containing an independently operating, loaded check valve and an independently operating, loaded air inlet valve located on the discharge side of the check valve. The assembly shall be equipped with properly located test cocks and tightly closing shutoff valves located at each end of the assembly.
F. Atmospheric vacuum breaker: Also known as the "nonpressure type vacuum breaker," shall mean an assembly containing a float check, a check seat and an air inlet port. The flow of water into the body causes the float to close the air inlet port. When the flow of water stops, the float falls and forms a check valve against backsiphonage and at the same time opens the inlet port to allow air to enter and satisfy the vacuum. A shutoff valve immediately upstream may be an integral part of the assembly. An atmospheric vacuum breaker is designed to protect against a health hazard (i.e. contaminant) under a back-siphonage condition only.
Certified tester: A person who has proven competency to the satisfaction of the Director of Public Works. Each person certified to make competent tests or to repair, overhaul and make reports on backflow prevention assemblies shall be conversant with the applicable laws, rules and regulations and have had experience in plumbing or pipe fitting or have other qualifications which are equivalent in the opinion of the Director of Public Works.
Contamination: An impairment of the quality of the potable water by sewage, industrial fluids, waste liquids, compounds or other materials to a degree which creates an actual or potential hazard to the public health through poisoning or through the spread of disease.
Cross-connection: Any physical connection or arrangement of piping or fixtures between two (2) otherwise separate piping systems, one (1) of which contains potable water and the other nonpotable water or industrial fluids of questionable safety, through which or because of which backflow may occur into the potable water system. A water service connection between a public potable water distribution system and a customer's water distribution system which is cross-connected to a contaminated fixture, industrial fluid system or with a potentially contaminated supply or auxiliary water system, constitutes one (1) type of cross-connection. Other types of cross-connections include connectors such as swing connections, removable sections, four-way plug valves, spools, dummy sections of pipe, swivel or change-over devices, sliding multi-port tube, solid connections, etc.
Cross-connections controlled: A connection between a potable water system and a nonpotable water system with an approved backflow prevention device properly installed and maintained so that it will continuously afford the protection commensurate with the degree of hazard.
Cross-connection control by containment: The installation of an approved backflow prevention device at the water service connection to any customer's premises where it is physically and economically infeasible to find and permanently eliminate or control all actual or potential cross-connections within the customer's water system, or it shall mean the installation of an approved backflow prevention device on the service line leading to and supplying a portion of a customer's water system where there are actual or potential cross-connections which cannot be effectively eliminated or controlled at the point of cross-connection.
Current cost (also current front foot cost): Costs involved in construction of a waterline, including engineering, construction and inspection, usually given as a per foot cost; established annually so as to reflect the most recent costs derived from local bids and contractors' and suppliers' price quotations.
Developer: Any person or persons, corporation, partnership or firm desiring municipal water service.
Director of Public Works: In the absence of a specific designation of authority by the City Manager, it will be the Director of the Public Works and Utilities Department charged with enforcement of the provisions of this chapter.
Distribution system: The network of public waterlines sixteen (16) inches in diameter and smaller which compose the basic grid and distribution system for Municipal water service.
Fire line: A private waterline located primarily on private property which is utilized exclusively for providing water to fixed fire protection systems.
Hazard, degree of: The term is derived from an evaluation of the potential risk to public health and the adverse effect of the hazard upon the potable water system.
A. Hazard, health: Any condition, device or practice in the water supply system and its operation which could create or in the judgment of the Director of the Transportation and Development Department may create a danger to the health and well-being of the water consumer. An example of a health hazard is a structural defect, including cross-connections, in a water system.
B. Hazard, plumbing: A plumbing type cross-connection in a consumer's potable water system that has not been properly protected by a vacuum breaker, air-gap separation or backflow prevention device. Unprotected plumbing type cross-connections are considered to be a health hazard.
C. Hazard, pollutant: An actual or potential threat to the physical properties of the water system or to the potability of the public or the consumer's potable water system but which would constitute a nuisance or be aesthetically objectionable or could cause damage to the system or its appurtenances, but would not be dangerous to health.
D. Hazard, system: An actual or potential threat of severe damage to the physical properties of the public potable water system or the consumer's potable water system or of a pollution or contamination which would have a protracted effect on the quality of the potable water in the system.
Hazardous material: Any material or combination of materials which, because of its quantity, concentration, or physical, chemical or infectious characteristics, may pose a substantial or potential hazard to human health or the environment.
Industrial fluids system: Any system containing a fluid or solution which may be chemically, biologically, or otherwise contaminated or polluted in a form or concentration such as would constitute a health, system, pollutant, or plumbing hazard if introduced into an approved water supply. This may include, but not be limited to: polluted or contaminated waters; all types of process waters and "used waters" originating from the public potable water system which may have deteriorated in sanitary quality; chemicals in fluid form, plating acids and alkalies, circulated cooling waters connected to an open cooling tower and/or cooling towers that are chemically or biologically treated or stabilized with toxic substances; contaminated natural waters such as from wells, springs, streams, rivers, urban lakes, irrigation canals or systems, etc., oils, gases, glycerine, paraffins, caustic and acid solutions and other liquid and gaseous fluids used in industrial or other purposes or for fire-fighting purposes.
Municipal water service: Water service provided for domestic, commercial, recreational, and landscaping purposes.
Nonresidential: Any structure which is not residential.
Pollution: The presence of any foreign substance (organic, inorganic or biological) in water which tends to degrade its quality so as to constitute a hazard or impair the usefulness or quality of the water to a degree which does not create an actual hazard to the public health but which does adversely and unreasonably affect such waters for domestic use.
Private waterline: Any waterline not owned and maintained by the City.
Public waterline or public water main: A waterline owned and maintained by the City.
Reclaimed water: Effluent which has been treated to achieve a quality suitable for its intended use as prescribed by Federal and State regulations.
Reimbursement agreement: An agreement executed between the City and developers for collection of buy-in assessments.
Residential: Single-family homes, duplexes, and triplexes.
Service line: A pipe carrying water from the public waterline to a water meter or other point of distribution.
Transmission main: A public waterline generally larger than sixteen (16) inches in diameter.
Water, potable: Any water which, according to recognized standards, is safe for human consumption.
Water, nonpotable: Water which is not safe for human consumption or which is of questionable potability.
Water service connections: The terminal end of a service connection from the public potable water system, i.e., where the City loses jurisdiction and sanitary control over the water at its point of delivery to the customer's water system. If a meter is installed at the end of the service connection, then the service connection shall mean the downstream end of the meter. There should be no unprotected takeoffs from the service line ahead of any meter or backflow prevention device located at the point of delivery to the customer's water system. Service connection shall also include water service connection from a fire hydrant and all other temporary or emergency water service connections from the public potable water system. However, except in the case where residential homes incorporate the use of reclaimed wastewater as a water conservation measure, the service connection shall be at the pipe union located beyond the approved backflow prevention device. There shall be no connections made upstream of the pipe union. The City system shall include all piping between the water meter and the pipe union, including the backflow prevention device.
Water, used: Any water supplied by the City from a public potable water system to a consumer's water system after it has passed through the point of delivery and is no longer under the sanitary control of the City.
(Ord. No. 2149, § 1.B, 9-13-90; Ord. No. 3060, § 2, 11-18-99; Ord. No. 3311, § 8, 9-27-01; Ord. No. 4365, § 31, 6-14-12; Ord. No. 4802, § 2(Exh., § 34), 4-26-18)