Long Beach Municipal Code § 22.41.010 Tables 41-1 through 41-5 of this Chapter establish development standards.
22.41.010 - Tables 41-1 through 41-5 of this Chapter establish development standards.
1. Applicability. This Chapter establishes development standards applicable to all new construction and additions to existing development in the neo-industrial districts. Tables 41-1 through 41-5 denote development standards for NI-1 and NI-2 zones.
2. Intensity (FAR). The intensity of neo-industrial development shall not exceed the maximum FAR.
a. Gross floor area dedicated to parking structures shall not be included in the FAR calculation.
3. Building Height. Building height shall be regulated by maximum number of stories and the dimensional height of the structure.
a. Building height shall be measured as defined by Section 21.15.1190 (Grade) and 21.15.1330 (Height of Building).
b. Measurement of building height in the NI-1 and NI-2 districts shall exclude the following features:
i. Vertical architectural projections (building elements added for architectural interest without adding interior floor area, such as towers and cupolas), not to exceed 10 feet above parapet height.
ii. Horizontal architectural projections which cantilever 5 feet or less from the exterior wall (or rooftop feature) shall not be included as part of the exterior wall line.
iii. Rooftop guard rails.
iv. Permanent unenclosed roof deck features located 2 feet or more from the exterior wall plane (including shade or partial covering structures, or similar features) up to 50% of the principle building footprint.
v. All mechanical equipment (including solar panels or other alternative energy equipment/infrastructure, elevator and mechanical equipment penthouses, and all associated screening features).
4. Development Sites.
a. Development created through lot consolidation shall be developed as a unified site.
b. Consolidation of sites is permitted and encouraged, consistent with subdivision regulations, however consolidation shall avoid creating isolated parcels that are not part of the development site.
c. At the time of lot consolidation, the new development site shall identify primary and secondary (if applicable) frontages as defined in 22.30.140.
5. Green Building Standards New construction and renovations shall be subject to the requirements of 21.45.400 (Green Building Standards) based on project type and gross square footage thresholds as outlined by 21.45.400.
6. Outdoor storage and activities. Outdoor storage and activities for NI zones shall be permitted subject to the following standards contained herein:
a. Outdoor storage. Accessory outdoor storage of goods, materials, or equipment shall be permitted only in the side and rear yards. However, no materials shall be stored within any required street side yard setback. All outdoor storage areas shall be completely screened from view from public rights-of-way and adjacent properties with screening the same height as the materials being stored. Stored goods and materials shall not exceed a stacking height of eight feet (8′) unless a permit is approved through Subsection 22.41.020.5.e.
b. Activities. No outdoor production, processing, or manufacturing activities associated with a business shall be permitted at any time. All such activities must be conducted within an entirely enclosed structure. This restriction shall not apply to loading operations or other necessary support functions of a business.
c. Screening Required. Screening shall be required for all outdoor storage and activities associated with industrial use development as identified herein subject to Subsection 22.41.020.5.
Table 41-1 Development Standards: Intensity
Zones | Notes and Exceptions Code section numbers reference the Long Beach Municipal Code
NI-1 (Neo-Industrial Focused) | NI-2 (Flexible Designation: Neo-Industrial + Commercial)
Lot Size
Minimum Lot Size | 5,000 square feet | Only applies to subdivision actions under Title 20.
Height/Stories
Maximum Building Height | 40 ft. to 65 ft. | Refer to Figure 3 (Citywide Height District Map)
Floor Area Ratio
Maximum Permitted Floor Area Ratio | 1.0 | 1.0 | Sections 21.15.1070 and 21.15.1090
[image omitted; see the official code]
Figure 3 Height Development Standards - Refer to Table 41-2
[image omitted; see the official code]
Figure 4 Setback Development Standards - Refer to Table 41-2
[image omitted; see the official code]
Figure 5 Stepback Development Standards - Refer to Table 41-2
Table 41-2 Development Standards: Building Placement & Activation
Zones | Notes and Exceptions Code section numbers reference the Long Beach Municipal Code
NI-1 (Neo-Industrial Focused) | NI-2 (Flexible Designation: Neo-Industrial + Commercial)
Minimum Required Measured Property Line to Building Face Setbacks (Feet)1
STREET SETBACKS
Buildings with Height up to 36 Feet
A Building Setback on a Primary Street | 10 ft. | 12 ft. | Refer to Figure 4 & 5
B Building Setback on a Secondary Street | 6 ft | 6 ft. | Refer to Figure 4
Buildings with Height greater than 36 Feet
A Building Setback on a Primary Street | 15 ft. | 15 ft. | Refer to Figure 4 & 5
B Building Setback on a Secondary Street | 16 ft. | 16 ft. | Refer to Figure 4
INTERIOR BUILDING SETBACKS (FEET)1
C Alley | 6 ft.; 32 ft. minimum building to building dimension across an alley | Minimum alley dimension shall not be less than 20 ft.
Adjacent to existing zones where residential uses are permitted, where not separated by an alley
D Ground Floor | 20 ft. | 20 ft.
E Upper Floors | Above 36 ft. from finished grade, stepbacks shall apply consistent with Figure 4 (45-degree angle diagram) Measured parcel line to building face
Adjacent to existing zones where residential uses are prohibited, where not separated by an alley
F All Other Adjacencies | 0 ft. | 0 ft. | Measured parcel line to building face
Setbacks between buildings on the same site
G Building to building | As required by Fire Code and Uniform Building Code | Separation measured building face to building face
REAR PARKING STANDARDS
H Rear Parking | 24 feet minimum | From edge of centerline of alley to garage or roll-up door face
LOADING DOCKS STANDARDS
I Loading Docks | Shall be provided for all uses that require truck loading spaces per LBMC 21.41.345 or that contain more than forty thousand (40,000) square feet of GFA in a single lease over ownership area. | Refer to Section 21.41.310-370
J Loading Space Standards | Passenger = 9 feet by 19 feet, 10-foot clearance Large Truck 14 feet by 60 feet, 15-foot clearance Reduced Truck = 12 feet by 25 feet, 12-foot clearance
K Loading Sizes | 2 sizes of loading spaces
L Loading Location | Outside of required aisles, circulation areas or within required setback areas adjacent to residential use or zoned properties.
M Loading Backing into street | Loading areas may be designed to allow trucks to back into the local or collector street subject to approval from Director of Public Works
N Loading Turning Radius | Loading areas shall be located to provide an adequate turning radius. Adequate turning radius means one which allows a vehicle to maneuver without backing into a street or without backing into the loading space from a street.
O Loading Spaces Screening | Loading spaces shall be separated from adjoining, abutting or adjacent residential districts by a building or masonry wall not less than six feet (6′) in height.
Notes: 1. Projections are permitted in the required setbacks in accordance with Section 21.32.220(C) of the Zoning Regulations.
(ORD-24-0015 § 1(Exh. A), 2024)