§ 29.56 — 702.4 Emergency Escape and Rescue Openings
Cedar Rapids, Iowa, Municipal Code (Supp. No. 25, Update 1: codified through Ordinance No. 025-26, passed July 28, 2026) · Cedar Rapids Municipal Code § 29.56
Corpus is an independent public-information project, not the official City of Cedar Rapids website. Stable reference: corpuslaw.us/code/be170c0b-769d-45e2-95c0-288e63016f43
29.56 - 702.4 Emergency Escape and Rescue Openings.
Section 702.4 of the IPMC is hereby amended by adding the following as item 3 to said section: 3. Emergency escape and rescue openings shall have a net clear opening of not less than 5.7 square feet. The minimum net clear opening for grade-floor emergency escape and rescue openings shall be 5 square feet. The minimum net clear opening height shall be 24 inches. The minimum net clear opening width dimension shall be 20 inches. The net clear opening dimensions shall be the result of normal operation of the opening. Emergency escape and rescue openings shall have the bottom of the clear opening not greater than 44 inches above the floor. Emergency escape and rescue openings installed under decks, porches and cantilevers shall be fully openable and provide a path not less than 36 inches in height and 36 inches in width to a yard or court. (033-24)
Ask a question about Cedar Rapids law
Corpus searches the Cedar Rapids sections it holds and shows the ones that match, with their citations. Free, no sign-in.