18.10.040 - Section R105.2 Work exempt from permit.
Exemption from permit requirements of this code shall not be deemed to grant authorization for any work to be done in any manner in violation of the provisions of this code or any other laws or ordinances of this jurisdiction. Permits shall not be required for the following construction work:
Building:
1. One-story detached accessory storage building, canopy or structure, located in the rear yard, less than two hundred square feet in floor area and not within 5 feet of another structure, eave to eave. This exemption shall be restricted to only one accessory building within a site.
2. Masonry landscape walls and fences not over forty-two inches high, completely within the subject property and meeting zoning requirements. Where there is a difference in elevation between abutting properties or property lines, the height measurement shall be taken from the high side of the wall, exclusive of retaining walls.
a. Chain link or wrought iron fences not over six feet high, completely within the subject property and meeting zoning requirements.
3. Concrete walks, slabs on grade and driveways not more than thirty inches above grade, that are not over a basement or story below; and that will not serve as foundation or structural support for future construction, and are not located in public right-of-way.
4. Ordinary minor nonstructural repair work such as painting, papering, siding and similar finish work.
5. Movable cases, cabinets, counters, and partitions not over five feet nine inches high that do not establish a corridor.
6. Swimming pools, wading pools or ponds that are in-ground or above ground containing a body of water less than twenty-four inches in depth and less than five thousand gallons of water.
7. Replacement of less than twenty-five percent of existing roof covering on residential structures only.
8. Swings and other playground equipment.
Mechanical:
1. Portable heating appliances.
2. Portable ventilation equipment.
3. Portable cooling units.
4. Steam, hot or chilled water piping within any heating or cooling equipment regulated by the technical codes.
5. Replacement of any part which does not alter its approval or make it unsafe.
6. Portable evaporative coolers.
7. Self-contained refrigeration systems containing ten pounds (4.54 kg) or less of refrigerant and actuated by motors of one horsepower (746 W) or less.
Electrical:
1. Wiring devices or equipment installed by telephone, telegraph or other public service corporations used solely for the transmission of two-way communication.
2. Portable appliances or devices conforming to the electrical code, for operation from a receptacle outlet, provided such appliances are rated at no more than eighty percent of the branch circuit overprotective device.
3. Replacing or repairing flash or snap switches, receptacles, drop cords, replacing fuses, changing lamp sockets, or any other minor repairs of joints in wiring, fixtures, devices or equipment.
4. Ceiling fans, light fixtures, receptacle outlets or similar devices added onto an existing electrical circuit which has adequate capacity for the additional load in a one- or two-family residence; provided, however, that the work is performed by:
a. A homeowner, on property that is their primary residence; or
b. A master, journeyman or maintenance electrician licensed in accordance with Section 18.02.104.6.
Plumbing:
1. The stopping of leaks in drains, water, soil, waste or vent pipe; provided, however, that if any concealed trap, drainpipe, water, soil, waste or vent pipe becomes defective and it becomes necessary to remove and replace the same with new material, such work shall be considered as new work and a permit shall be obtained and inspection made as provided in this code.
2. The clearing of stoppages or the repairing of leaks in pipes, valves or fixtures, and the removal and reinstallation of water closets, provided such repairs do not involve or require the replacement or rearrangement of valves, pipes or fixtures.
(Ord. No. 019528, § 1, 8-1-2023)