Lighting plans.
Tulsa Revised Ordinances tit. 42, § 67.040
in effectSection 67.040. - Lighting plans.
A. General. Outdoor lighting plans demonstrating compliance with the standards of this section are required with the submittal of a site plan. If no outdoor lighting is proposed, a note must be placed on the face of the site plan indicating that no outdoor lighting will be provided. Applicants have two (2) options for the format of the required lighting plan:
1. Submit a lighting plan that complies with the fixture height lighting plan requirements of Subsection 67.040B.; or
2. Submit a photometric plan demonstrating that compliance will be achieved using taller fixture heights, in accordance with Subsection 67.040C.
B. Option 1: Fixture Height Standard Lighting Plan. Option 1 (Fixture Height Standard Lighting Plans) establishes maximum light fixture heights but does not require submittal of a detailed photometric plan.
1. Information required.
a. Fixture height standard lighting plans must include at least the following: A scale drawing of the site with all outdoor lighting locations shown;
b. Fixture specifications, including catalog cut-sheets or generic standards;
c. Pole type and height of fixture;
d. Lamp type and size; and
e. Fixture mounting and orientation.
2. Maximum Fixture Heights. Allowable heights of light fixtures must be measured from the light-emitting surface to finished grade at the base of the pole. Maximum allowed light fixture heights are based on the (ground-level) horizontal distance between the light fixture and any agricultural, agricultural-residential or residential zoning district or public right-of-way, as established in Table 67-1:
Table 67-1: Maximum Light Fixture Heights
Distance from AG District, AG-R District, R District or Public Right-of-Way (feet) | Maximum Fixture Height (feet)
0—50 | 16
50.01—250 | 20
More than 250 | 35
C. Option 2: Photometric Study. Under Option 2 (Photometric Study Lighting Plan) no maximum fixture heights are established, but applicants are required to submit a photometric study in enough detail to demonstrate that all applicable outdoor light standards will be met. The photometric study must include at least the following:
1. A scale drawing of the site with all outdoor lighting locations shown;
2. Fixture specifications, including catalog cut-sheets or generic standards;
3. Lamp type and size;
4. Fixture mounting heights, mounting orientation, and tilt angles if applicable; and
5. A representative point-by-point illumination array for the site showing property lines and all off-site lighting impacts.
(Ord. No. 24382, § 16, 6-10-2020)
Source: City of Tulsa, Revised Ordinances and City Charter (Municode Library, library.municode.com)URL: https://library.municode.com/ok/tulsa/codes/code_of_ordinances?nodeId=COOR_TIT42ZOCO_CH67OULI_S67.040LIPLFetched: 10/28/2026