18.68.022 - Symbols and notations.
For the purposes of this chapter, the following symbols and definitions shall apply: A = Area of unreinforced masonry pier, square inches. A b = Area of the bed joints above and below the test specimen for each in place shear test. C p = Numerical coefficient as specified in UBC Section 2312(g) and given in UBC Table 23-P and in Table A-23-A. D = In plane width dimension of pier, inches, or depth of diaphragm, feet. DCR = Demand capacity ratio specified in Subsection 18.68.027.D. Fwx = Force applied to a wall at level x, pounds. H = Lease clear height of opening on either side of pier, inches. h/t = Height/thickness ratio of URM wall. Height h is measured between wall anchorage levels, and/or slab on grade. L = Span of diaphragm between shear walls, or span between shear wall and open front, feet. L c = Length of crosswall, feet. L i = Effective span for an open front building specified in Subsection 18.68.027.D.8, feet. PD = Superimposed dead load at the top of the pier under consideration, pounds. P D+L = Actual dead plus live load in place at the time of testing, pounds. P W = Weight of wall, pounds. Σ v u D = Sum of diaphragm shear capacities of both ends of the diaphragm. Σ W d = Total dead load tributary to all of the diaphragms coupled at and above the level under consideration, pounds. ΣΣ v u D = For diaphragms coupled with crosswalls ΣΣ v u D includes the sum of shear capacities of both ends of diaphragms coupled at and above the level under consideration. V a = v a A, the allowable shear in any URM pier, pounds. V ca = Total shear capacity of crosswalls in the direction of analysis immediately above the diaphragm level being investigated, S v c L o , pounds. V cb = Total shear capacity of crosswalls in the direction of analysis immediately below the diaphragm level being investigated, S v c L o , pounds. V r = Pier rocking shear capacity of any URM wall or wall pier, pounds. V wx = Total shear force resisted by a shear wall at the level under consideration, pounds. V p = Shear force assigned to a pier on the basis of its relative shear rigidity, pounds. V S = Shear force assigned to a spandrel on the basis of the shear forces in the adjacent wall piers and tributary dead plus live loads. V test = Load in pounds at incipient cracking for each in-place masonry shear test per Standard No. 24-40. (See Section 18.68.220.) v a = Allowable shear stress for unreinforced masonry, psi. v c = Allowable shear value for a crosswall sheathed with any of the materials given in Tables A-23-C or A-23-D, pounds per foot. v t = Mortar shear strength as specified in Subsection 18.68.024.C.3.d. v to = Mortar shear test values as specified in Subsection 18.68.024.C.3.d. v u = Allowable shear value for a diaphragm sheathed with any of the materials given in Tables A-23-C or A-23-D, pounds per foot. W d = Total dead load tributary to a diaphragm, pounds. W w = Total dead load of an unreinforced masonry wall above the level under consideration or above an open front of a building, pounds. W wx = Dead load of a URM wall assigned to level x halfway above and below the level under consideration.
(ORD-25-0019 § 1(Exh. A), 2025; ORD-22-0033 § 1(Exh. A), 2022; ORD-19-0031 § 1(Exh. A), 2019; ORD-16-0026 § 1(Exh. A), 2016)
Ask a question about Long Beach law
Corpus searches the Long Beach sections it holds and shows the ones that match, with their citations. Free, no sign-in.