Scottsdale Revised Code § 49-161 General industrial user requirements.
Sec. 49-161. - General industrial user requirements.
(a) General Prohibitions. No user shall introduce or cause to be introduced, directly or indirectly, into the POTW any pollutant or wastewater which causes pass through or interference. These general prohibitions and the specific prohibitions in paragraph (b) of this section apply to all users of the POTW, regardless of whether the user is subject to any national, state, or local pretreatment standards or requirements.
All non-residential users may be required to submit a chemical inventory list upon request by the Division including details on chemicals used or stored that may have the potential to be introduced into the POTW.
(b) Specific Prohibitions: No user shall introduce or cause to be introduced into the POTW the following pollutants, substances, or wastewater:
(1) Pollutants which create a fire or explosion hazard in the POTW, including, but not limited to, wastestreams with a closed cup flashpoint of less than 140 degrees F (60 degrees Celsius) using the test methods specified in 40 CFR § 261.21;
(2) Wastewater having a pH of less than 5.0 or more than 10.5 or that otherwise causes corrosive structural damage to the POTW or equipment;
(3) Solid or viscous pollutants, fats, oils, or grease in amounts or sizes which will cause obstruction of the flow in the POTW or result in interference or otherwise disrupt the operation of the POTW or any private sewer;
(4) Any pollutants, including oxygen-demanding pollutants (e.g., BOD), released in a discharge at a flow rate and/or pollutant concentration which, either alone or by interaction with other pollutants, will cause interference with the POTW;
(5) Heat in amounts which will inhibit biological activity in the POTW resulting in interference, but in no event heat in such quantities that the temperature at a POTW exceeds 104 degrees Fahrenheit (40 degrees Celsius) or any wastewater at a temperature greater than 150 degrees Fahrenheit (65 degrees Celsius);
(6) Petroleum oil, nonbiodegradable cutting oil, or products of mineral oil origin in amounts that will cause interference or pass through;
(7) Pollutants which result in the presence of toxic gases, vapors, or fumes within the POTW in a quantity that may present an acute risk to worker health and safety or prevent entry into the sewers for maintenance, repair, sampling, or monitoring;
(8) Any trucked or hauled pollutants, unless the hauler has first obtained written approval from the division.
(9) Hazardous waste that violates any local limit contained in this article;
(10) Any of the following prohibited substances:
a. 4,4'—DDE
b. 4,4'—DDT
c. Aldrin
d. BHC—Alpha.
e. BHC—Beta.
f. BHC—Gamma (Lindane).
g. Heptachlor.
h. Heptachlor epoxide.
i. Polychlorinated biphenyl compounds (PCBs).
(11) Any wastewater which exceeds the following limits for the following substances:
Substance | Limitation(1) | Sample Type
Benzene | 35 μg/l | Grab
Chloroform | 2000μg/l | Grab
(1) µg/l = micrograms per liter
(12) Noxious or malodorous liquids, gases, solids, or other wastewater which either alone or by interaction with other wastes are sufficient to create a nuisance or a hazard to life, generate odor complaints, or to prevent entry into the sewers for maintenance or repair;
(13) Wastewater containing any radioactive wastes or isotopes except in compliance with applicable state or federal regulations;
(14) Stormwater, surface water, ground water, artesian well water, roof runoff, subsurface drainage, condensate, noncontact cooling water, and unpolluted wastewater unless specifically authorized by the division.
(15) Sludges, screenings, and other residues from the pretreatment of industrial wastes or from the cleaning of interceptors or sewer collection systems;
(16) Medical wastes except as specifically authorized by the division in a wastewater discharge permit;
(17) Wastewater causing, alone or in conjunction with other sources, the POTW's effluent to fail a toxicity test;
(18) Detergents, surface active agents, or other substances which might cause excessive foaming in the POTW; or
(19) Wastewater causing a reading on an explosion hazard meter at the point of discharge into the POTW, or at any point in the POTW, of more than ten (10) percent of the Lower Explosive Limit of the meter.
(c) National Categorical Pretreatment Standards. Users must comply with the applicable categorical pretreatment standards under 40 CFR § 403.6 and 40 CFR chapter I, subchapter N, Parts 405-471 which are hereby incorporated by this reference.
(1) Where a categorical pretreatment standard is expressed only in terms of either the mass or concentration of a pollutant in wastewater, the division may impose equivalent concentrations or mass limits in accordance with 40 CFR § 403.6(c).
(2) When wastewater subject to a categorical pretreatment standard is mixed with wastewater not regulated by the same standard, the division shall impose an alternative limit in accordance with 40 CFR § 403.6(e) or require the user to take other steps as necessary to allow the user and the City to determine compliance with the applicable standards.
(3) A user may obtain a net/gross adjustment to a categorical pretreatment standard in accordance with 40 CFR § 403.15.
(d) Local Limits and Pretreatment Standards including Enhanced Source Control POTW Operational Parameters.
(1) The division is authorized to establish local limits pursuant to 40 CFR § 403.5(c) and the IGA.
(2) The following pollutant limits are established to protect against pass through or interference and to implement provisions of this article. No user shall discharge wastewater that exceeds the following limits at any time for any length of time:
a. Parameter | Daily/Maximum Limit(1)or Instantaneous Limit
Arsenic | 0.13 mg/l
Cadmium | 0.047 mg/l
Copper | 1.5 mg/l
Cyanide | 2.0 mg/l
Lead | 0.41 mg/l
Mercury | 0.0023 mg/l
Selenium | 0.10 mg/l
Silver | 1.2 mg/l
Zinc | 3.5 mg/l
(1) All pollutants are to be analyzed as Total.
b. Any chemicals and their associated limits referenced in the Arizona Department of Environmental Quality's Advanced Water Purification Rule, Part E, and EPA's 2018 Edition of the Drinking Water Standards and Health Advisories Tables, and any amendments thereof. The division shall update and maintain a table of pollutant limits in accordance with the Advanced Water Purification Rule. A copy of the table can be obtained from the Division upon request.
(3) The division may develop Best Management Practices (BMPs) for any significant industrial user or other user, as needed, to implement this article. BMPs may be implemented through a permit, order, or regulation. For purposes of this article, BMPs are pretreatment requirements.
(4) All users subject to a categorical pretreatment standard shall comply with all requirements of such standard, and shall also comply with any limitations and prohibitions contained in this article. Where the same pollutant is limited by more than one pretreatment standard, the limitations which are more stringent shall prevail. Compliance with categorical pretreatment standards for existing sources shall be within the timeframe specified in the applicable categorical pretreatment standard. Compliance with categorical pretreatment standards for new sources shall be upon commencement of discharge.
(5) The division may establish more stringent pretreatment standards or additional site-specific effluent limits, when, in the judgment of the division, such limitations are necessary to implement the objectives of this article.
(6) The division may require an onsite real time analyzer(s) at the sole discretion of the division to warn the POTW of a discharge that may negatively impact the POTW through interference or pass through. The division will work with the discharger on reporting requirements that adequately provide notification to the division.
(e) Authority of division director to establish prohibitions and effluent limits.
(1) In addition to the prohibitions, standards, and effluent limits outlined in this section, the division director is authorized to:
(i) Establish limits for individual users or a class of users for various pollutants, materials, waters, or wastes that can be accepted into the sewer system; and
(ii) Specify those pollutants, materials, waters, or wastes that are prohibited from entering the sewer system.
(2) All prohibitions and effluent limits so established will be published by the division and placed on the Water Resources Division website and will be enforceable 30 days after the date posting.
(3) All affected individual users or class of users must comply with the prohibitions and effluent limits established pursuant to this section.
(f) Mass Based Limitations. The division may impose mass limitations on industrial users through industrial wastewater discharge permits where not prohibited by categorical pretreatment standards, and which are using flow equalization to meet applicable federal, state, or City pretreatment standards or requirements, or in other cases where the imposition of mass limitations are appropriate. The division may establish equivalent mass limits only if industrial users satisfy all conditions set forth in 40 CFR 403.6(c)(5)(i)(A) through (c)(5)(i)(E). In such cases, the wastewater discharge permit will contain the mass allocation for each pollutant, any concentration-based categorical standards, maximum flow allowed, and the appropriate monitoring and reporting requirements. Where mass limits have been established, the reports required by sections 49-167(c) and (d) shall also indicate the mass of limited pollutants in the user's wastewater. These reports shall also contain the results of sampling and analysis of the discharge, including production and mass of pollutants contained therein which are limited by the applicable pretreatment standards and requirements.
(g) Dilution. No user shall ever increase the use of process water or in any way attempt to dilute a discharge as a partial or complete substitute for adequate treatment to achieve compliance with any discharge limitation unless expressly authorized by an applicable pretreatment standard or requirement. The division may impose mass limitations and flow limitations on users who are using dilution to meet applicable pretreatment standards or requirements or in other cases when the imposition of mass limitations and flow limitations are appropriate.
(h) Point of Discharge: Prohibitions.
(1) No person shall discharge any substance directly into a manhole or other opening into the POTW unless specifically authorized by the division or as otherwise permitted under this article.
(2) Liquid wastes from chemical toilets originating from campers, trailers and other recreational vehicles which have been collected and/or held in tanks or other containers shall not be discharged into the POTW except at locations authorized by the division to collect such wastes within the City.
(3) No person shall discharge or dispose of wastes into the POTW where such wastes have been collected and/or held in a tank or other container and where such wastes fail to comply with any limitation set out in this article.
(i) Tampering Prohibition.
(1) No person shall tamper with, damage, or destroy any monitoring or sampling equipment with the knowledge or intention of altering the sampling analysis or readings or causing damage to such equipment being used to determine compliance with this article.
(2) No person shall tamper with a manhole or enter any City manhole without specific authorization from the City.
(3) No person shall tamper with any pretreatment device, including, but not limited to, any unauthorized alteration of the original equipment or its design, any discharge of waste into the pretreatment device from any source other than as originally intended, or the removal of an originally intended source of discharge from the pretreatment device.
(Ord. No. 4616, § 1, 10-10-23; Res. No. 13395, § 1(Exh. A), 5-20-25)