§ 16-12. - Bridges and culverts.

(a) All flow of water across continuous streets or alleys must be through culverts or bridges. Bridges shall be designed such that the 100-year frequency flood flow will not overtop the roadway. In addition, the 50-year water surface elevation shall be below the low chord of a bridge. (b) Culverts shall be designed to carry the 50-year frequency flood flow with no more than one foot of headwater at the upstream end of the culvert and such that the 100-year frequency flood flow will not overtop the roadway. (c) No rise in the 100-year frequency flood flow water surface elevation will be allowed upstream of the bridge or culvert as a result of the construction or installation of any building or structure unless such increase is confined to the limits of the developer's property.

(Ord. No. 27691, § 2, 9-24-24)