Sec. 102-217. - Mains and service wires.
(a) In bringing out of buildings mains which are to be supported by overhead service, the outlet must not be so located that the subsequent erection of an adjoining building might render it inaccessible. The main must be brought out at the front or rear wall, or along the street side if a corner building, and must be so placed that moisture cannot form a cross connection. Mains shall not be less than a foot apart, and shall not be in contact with any substance other than their insulation supports. Wooden blocks to which insulators are attached must be covered over the entire surface with at least two coats of waterproof paint. (b) Fixtures to which insulators are attached must be covered over their entire surface with at least two coats of waterproof paint; when permitted, such fixtures must be at least seven feet above the highest point of flat roofs, and at least one foot above the ridge of pitched roofs over which they pass, or to which they are attached; but in new installations, service leads from poles to buildings must not enter buildings over the roof nor down the light shaft or court except with special permission and must be protected by dead insulated guard irons or wires from possibility of contact with other conducting wires or substances to which currents may leak. Special precautions of this kind must be taken where sharp angles occur or where any wires might possibly come in contact with electric light or power wires. (c) Crosses, when unavoidable, must be made as nearly at right angles as possible; must be provided with petticoat insulators of glass or porcelain—porcelain knobs or cleats and rubber hooks will not be approved; and must be so spliced or joined as to be both mechanically and electrically secure without solder. The joints must then be soldered to ensure preservation, and covered with an insulation equal to that on the conductors. (d) All joints must be soldered, even if made with some form of patent splicing device. This provision applies to joints and splices in all classes of wiring covered by this article and must, where they enter buildings, have drip loops outside; and the holes through which the conductors pass must be bushed with noncombustible, nonabsorptive, insulating tubes slanting upward toward the inside. (e) For low potential systems the service wires may be brought into buildings through a single iron conduit, the conduit to be curved downward at its outer end and equipped with an approved service head to prevent the entrance of moisture. The outer end must be at least one foot from any woodwork, and the inner end must extend to the service cutout. (f) Electric light or power wires must not be placed on the same crossarm with telegraph, telephone and similar wires; and when placed on the same pole with such wires, the distance between the two inside pins of each crossarm must not be less than 28 inches. (g) The metallic sheaths to cables must be permanently and effectively connected to earth. (h) Wires under sidewalks, especially likely to be injured, must be substantially protected. (i) When wires come in contact with pipes, cornices, awning frames and covers, and places where bends occur outside of buildings, they must be protected by flexible metallic conduits running from one support to the other. The ends of the conduits must be equipped with an approved fitting. Flexible fibrous tubing will not be permitted on outside work.
(Code 1975, § 21-6)
Ask a question about Charleston law
Corpus searches the Charleston sections it holds and shows the ones that match, with their citations. Free, no sign-in.