223-9. Stationary Engineer’s Permit to Operate.
1. SCOPE. Except as provided in sub. 2, this section shall apply to all boiler plants and steam engines and turbine. a. No person may operate, manage or take charge of any boiler, steam engine or steam turbine regulated by this chapter without first procuring stationary engineer’s permit to operate. b. No person owning or controlling any boiler, steam engine or steam turbine may authorize or permit any person who does not have a proper and valid permit to operate, have control of, manage or take charge of such boiler, steam engine or steam turbine or any part thereof. c. Boilers which use liquids other than water shall be subject to the same permit requirements determined by the boiler horsepower rating and safety valve setting of the boilers, except that a person having only a low pressure boiler operator permit shall not be permitted to operate such boilers. 2. EXCEPTIONS. The permit regulations of this section shall not apply to: a. Boiler plants consisting of one or more low pressure boilers with a total capacity not greater than 30 BHP as rated by boiler manufacturer rating plate or Wisconsin state code. b. Boiler plants consisting only of one or more miniature boilers which are used as separate units. c. Steam engines or turbines which are supplied with steam from a miniature steam boiler. d. Locomotives used in interstate commerce. e. Low pressure boiler heating plants in one and 2-family dwellings. . f. Any boiler completely filled with water or other liquid, to be used externally to itself at pressure not greater than 160 pounds per square inch, or at a temperature not greater than 250 degrees Fahrenheit. 3. PERMIT TO OPERATE CLASSIFICATION. Five classes of stationary engineers’ permits to operate are established: a. First class stationary engineer’s permit. b. Second class stationary engineer’s permit. c. Third class stationary engineer’s permit. d. Fourth class stationary engineer’s permit. e. Low pressure boiler operator’s permit. 4. APPLICATION AND EXPERIENCE. a. Application for a permit to operate under this chapter may be made by any person holding a National Institute for the Uniform Licensing of Power Engineers (NIULPE) license or an American Society of Power Engineers (ASOPE) license. b. The commissioner shall determine the applicant’s fitness for a particular class of permit. The city’s permit classifications shall correspond to the following NIULPE or ASOPE classifications: Milwaukee | NIULPE | ASOPE Low Pressure Boiler Operators Permit | 5th Class License | Facility Operating Engineer 3rd Class License Fourth Class Stationary Engineers Permit | 4th Class License | Facility Operating Engineer 2nd Class License Third Class Stationary Engineers Permit | 3rd Class License | Power Plant Operating Engineer 3rd Class License Second Class Stationary Engineers Permit | 2nd Class License | Power Plant Operating Engineer 2nd Class License First Class Stationary Engineers Permit | 1st Class License | Power Plant Operating Engineer 1st Class License c. A verified application for a permit to perform work as an engineer in the city shall be made on forms furnished by the commissioner. d. The applicant shall list education and work experience relating to the operation of boiler plants. Applications for stationary engineer’s permit to operate should contain the name of the engineer in charge of the plant where the applicant worked, whenever possible. e. An applicant for a low pressure boiler operator’s permit to operate must demonstrate good mechanical aptitude, present evidence of successful completion of an approved stationary engineer’s course and the NIULPE or ASOPE student engineer’s exam or other equivalent NIULPE or ASOPE licence. 5. GRANTING OF PERMITS TO OPERATE AND FEES. a. Upon approval by the commissioner the department shall issue a permit to operate to the successful applicant within 7 days after certification. b. For fees see s. 200-33. 6. SUSPENSION AND REVOCATION OF PERMIT TO OPERATE. a. Causes. The commissioner may suspend or revoke the permit of any stationary engineer for any of the following violations: a-1. The making of any material false statement on any application for a permit. a-2. Permitting the water in the boiler to go too low. a-3. Permitting a higher pressure other than that fixed by the commissioner. a-4. Unnecessary absence from post of duty. a-5. Failure to report in writing to the commissioner any defect in or accident to any boiler, steam engine or turbine under the permittee’s care. a-6. Failure to keep a daily log in the boiler, steam engine or turbine room. a-7. A showing that the permittee has violated any provision of this chapter. b. Commencement of Proceedings. The commissioner may institute suspension or revocation proceedings. However, the permittee shall be given the opportunity to be heard in his or her own defense prior to any permit suspension or revocation. 7. APPEALS AND BOARD OF ARBITRATION. Any person who wishes to appeal a decision of the commissioner concerning the granting, suspension or revocation of a permit shall file a notice of appeal with the standards and appeals commission as provided for in s. 200-17. 8. GENERAL OPERATION REGULATIONS. a. Notification of Absence by Employer. In any case where a permit to operate holder in charge of a plant is temporarily unable to report to duty because of sickness, personal injury or for any other reason or cause, the employer of the permit to operate holder shall immediately obtain the services of a substitute permit holder. The employer shall notify the commissioner within 24 hours that a substitute permit holder has taken charge of the plant. b. Temporary Operation. If the employer is unable to obtain the services of a permit holder having the class of permit required for the plant, he or she may apply to the commissioner for a permit to allow one of the following persons to take charge of the plant for the following specified periods of time: b-1. A stationary engineer having a lower class of permit than that required for the plant for a period not exceeding 60 days. b-2. Any person who does not have the required boiler operation experience, but can pass a written examination given by the commissioner on the operation of boilers and steam engines and turbines for a period not exceeding 30 days. c. Notice of Accidents by Engineer. Every stationary engineer who is in charge of a boiler, steam engine or turbine shall notify the commissioner in writing of any accident in which such equipment is involved within 24 hours after the accident occurs and report any serious defects or hazards in such equipment which might be contributory to a serious accident. d. Notice of Change in Employment. Every person permitted in this section shall notify the commissioner when his or her place of employment as a stationary engineer changes within 3 days from the date of change. e. Permit to be Displayed. Every person permitted under this section shall display his or her permit to operate under glass or other transparent material in a conspicuous place in the boiler, engine or turbine room. f. Unlawful to Exceed Boiler Pressures. It shall be unlawful to carry a higher pressure in any boiler other than as set by the commissioner in accordance with ch. SPS 341, Wis. Adm. Code, as amended, and the condition of the boiler as found upon inspection. g. Daily Log. Every stationary engineer permitted under this section shall keep a daily log in the boiler room to include the time and the day of checks being made on the boiler, engine or turbine. 9. FIRST CLASS PLANTS: OPERATION REQUIREMENTS. a. Personal Supervision. a-1. Each first class plant, when in operation, shall have a first class stationary engineer responsible for the safe operation of the plant. Such first class stationary engineer shall personally supervise the operation of the plant and shall be available at all times to make any decisions which may affect the safe operation of the plant. a-2. Where a first class plant which contains steam engines or turbines other than boiler auxiliaries is operated on a shift basis, a second class stationary engineer may act as an assistant and operate the plant on any shift. a-3. Where a first class plant which does not have any steam engines or turbines except boiler auxiliaries is operated on a shift basis, a fourth class stationary engineer may act as an assistant and operate the plant on any shift. a-4. Boilers, engines or turbines shall be operated by the stationary engineer in charge, or by an assistant with the proper operating permit, who shall be stationed in a position to manually control and visually monitor the control equipment except where permitted in s. 223-11. b. Automatic Controls; Personal Supervision. b-1. Where boilers, engines or turbines are equipped with control devices as set forth in subds. 2 or 3, the stationary engineer in charge or an assistant with the proper operating permit, shall be assigned to oversee the boilers, engines or turbines in operation. b-2. Control devices for boilers shall include the following functions: b-2-a. Monitor pressure and control firing rate. b-2-b. Monitor and control water level. b-2-c. Shut down boiler with dual shutoff valves. b-2-d. Where required, monitor and control low water cutoff with manual reset. b-2-e. Visual monitoring of equipment. (Note: Alarms are recommended for low water, high pressure and flame failure.) b-3. Control equipment for turbines and engines must control overspeed. b-4. Control equipment must be tested in accordance with ASME CSD-1 at least once per year, and certification of tests shall be required. Control devices and safety equipment shall be checked daily and logged, in addition to the yearly certification check. c. Separated Boilers, Engines and Turbines. Where the boiler room and the engine or turbine are separate and where the boilers, engines or turbines are not equipped with control devices and monitoring equipment, a second class stationary engineer shall be stationed at the engines or turbines and a fourth class stationary engineer shall be stationed at the boiler at all times while the boilers, engines or turbines are in operation. 10. SECOND CLASS PLANTS: OPERATION REQUIREMENTS. a. Personal Supervision a-1. Each second class plant, when in operation, shall have a second class stationary engineer responsible for the safe operation of the plant. Such second class stationary engineer shall personally supervise the operation of the plant and shall be available at all times to make any decisions which may affect the safe operation of the plant. a-2. Where a second class plant which contains steam engines or turbines other than boiler auxiliaries is operated on a shift basis, a third class stationary engineer may act as an assistant and operate the plant on any shift. a-3. Where a second class plant which does not have any steam engines or turbines, except boiler auxiliaries, is operated on a shift basis, a fourth class stationary engineer may act as assistant and operate the plant on any shift. a-4. Boilers, engines or turbines shall be operated by the stationary engineer in charge, or by an assistant with the proper operating permit who shall be stationed in a position to manually control and visually monitor the control equipment except where permitted in s. 223-11. b. Automatic Controls; Personal Supervision. b-1. Where boilers, engines or turbines are equipped with control devices, as set forth in subds. 2 or 3, the stationary engineer in charge or an assistant with the proper grade of permit shall be assigned to oversee the boilers, engines or turbines in operation. b-2. Control devices for boilers shall include the following functions: b-2-a. Monitor pressure and control firing rate. b-2-b. Monitor and control water level. b-2-c. Shut down boiler with dual shutoff valves. b-2-d. Where required, monitor and control low water cutoff with manual reset. b-2-e. Visual monitoring of equipment. (Note: Alarms are recommended for low water, high pressure and flame failure.) b-3. Control equipment for turbines and engines shall control overspeed. b-4. Control equipment shall be tested in accordance with ASME CSD-1 at least once per year and certification of tests shall be required. Control devices and safety equipment shall be checked daily and logged, in addition to the yearly certification check. c. Separated Boilers, Engines and Turbines. Where the boiler room and the engine or turbine room are separate and where the boilers, engines or turbines are not equipped with control devices and monitoring equipment, a third class stationary engineer shall be stationed at the engines or turbines, and a fourth class stationary engineer shall be stationed at the boiler at all times while the boilers, engines or turbines are in operation. 11. THIRD CLASS PLANTS: OPERATIONS REQUIREMENTS. a. Personal Supervision. a-1. Each third class plant, when in operation, shall have a third class stationary engineer responsible for the safe operation of the plant. The third class stationary engineer shall personally supervise the operation of the plant and shall be available at all times to make any decisions which may affect the safe operation of the plant. a-2. Where a third class plant which does not have any steam engines or turbines except boiler auxiliaries is operated on a shift basis, a fourth class stationary engineer may act as assistant and operate the plant on any shift. a-3. Boilers, engines or turbines shall be operated by the stationary engineer in charge, or an assistant with the proper operating permit, who shall be stationed in a position to manually control and visually monitor the control equipment except where permitted in s. 223-11. b. Automatic Controls; Personal Supervision. b-1. Where boilers, engines or turbines are equipped with control devices, as set forth in subds. 2 or 3, the stationary engineer in charge or an assistant with the proper operating permit shall be assigned to oversee the boilers, engines or turbines in operation. b-2. Control devices for boilers shall include the following functions: b-2-a. Monitor pressure and control firing rate. b-2-b. Monitor and control water level. b-2-c. Shut down boiler with dual shutoff valves. b-2-d. Where required, monitor and control low water cutoff with manual reset. b-2-e. Visual monitoring of equipment. (Note: Alarms are recommended for low water, high pressure and flame failure.) b-3. Control equipment for turbines and engines must control overspeed. b-4. Control equipment must be tested in accordance with ASME CSD-1 at least once per year and certification of tests shall be required. Control devices and safety equipment shall be checked daily and logged, in addition to the yearly certification check. c. Separated Boilers, Engines and Turbines. Where the boiler room and the engine or turbine room are separate and where the boilers, engines or turbines are not equipped with control devices and monitoring equipment, a third class stationary engineer shall be stationed at the engines or turbines and a fourth class stationary engineer shall be stationed at the boiler at all times while the boilers, engines or turbines are in operation. 12. FOURTH CLASS PLANTS: OPERATION REQUIREMENTS. a. Personal Supervision. a-1. Each fourth class plant, when in operation, shall have a fourth class stationary engineer responsible for the safe operation of the plant. The fourth class stationary engineer shall personally supervise the operation of the plant and shall be available at all times to make any decisions which may affect the safe operation of the plant. a-2. Boilers shall be operated by a fourth class stationary engineer who shall be stationed in a position to manually control and visually monitor the control equipment except where permitted in s. 223-11. b. Automatic Controls; Personal Supervision. b-1. Where boilers are equipped with control devices as set forth in subd. 2, a fourth class stationary engineer shall be assigned to oversee the boilers while in operation. b-2. Control equipment for boilers shall include the following functions: b-2-a. Monitor pressure and control firing rate. b-2-b. Monitor and control water level. b-2-c. Shut down boiler with dual shutoff valves. b-2-d. Where required, monitor and control low water cutoff with manual reset. b-2-e. Visual monitoring of equipment. (Note: Alarms are recommended for low water, high pressure and flame failure.) b-3. Control equipment must be tested in accordance with ASME CSD-1 at least once per year and certification of tests shall be required. Control devices and safety equipment shall be checked daily and logged, in addition to the yearly certification check. c. Separated Boilers. Where boiler rooms are separate and where the boilers are not equipped with control devices and monitoring equipment, a fourth class stationary engineer shall be stationed at each boiler at all times while the boilers are in operation. 13. LOW PRESSURE PLANTS: OPERATING REQUIREMENTS. a. Personal Supervision. a-1. Each low pressure plant, when in operation, shall have a low pressure boiler operator for the safe operation of the low pressure plant. The low pressure boiler operator shall personally supervise the operation of the plant and shall be available at all times to make any decisions which may affect the safe operation of the plant. a-2. Each low pressure plant, when in operation, shall have a low pressure boiler operator who shall visit the boiler at least twice each day except where permitted in s. 223-11. b. Number of Plants Supervised. If permitted by the commissioner, a low pressure boiler operator may take charge of not more than 5 low pressure plants. c. Daily Log. A daily log shall be maintained in the boiler room and be readily available for inspection. The permitted engineer shall check the boiler for safe operation and enter on the log the time and date on which the boiler was checked.
Ask a question about Milwaukee law
Corpus searches the Milwaukee sections it holds and shows the ones that match, with their citations. Free, no sign-in.