Sec. 6-31. - Specific standards for riverine zones.
In all areas of special flood hazard designated on the community's FIRM, where base flood elevation data have been provided (excluding CFHA and Coastal AE Zone), as set forth in section 6-11, the following provisions in addition to the standards in section 6-30 are required:
(1) Residential construction. New construction or substantial improvement of any residential building (or manufactured home) shall have the lowest floor, including basement, elevated no lower than eighteen (18) inches above the base flood elevation, (the community freeboard). Should solid foundation perimeter walls be used to elevate a structure, openings sufficient to automatically equalize hydrostatic flood forces on exterior walls of enclosures that are subject to flooding, shall be provided in accordance with standards of subsection (4) of this section. New development proposals will be designed, to the maximum extent practicable, so residential building sites, walkways, driveways, and roadways are located at natural grade with elevation not less than the base flood elevation and with evacuation routes leading directly out of the special flood hazard area.
(2) Non-residential construction. New construction or substantial improvement of any commercial, industrial, or nonresidential building (or manufactured home) shall have the lowest floor, including basement elevated to no lower than eighteen (18) inches above the level of the base flood elevation (the community freeboard). Buildings located in all A zones may, together with attendant utility and sanitary facilities, be floodproofed in lieu of being elevated provided that all areas of the building below the BFE (plus the minimum eighteen-inch community free board) are water tight with walls substantially impermeable to the passage of water, and use structural components having the capability of resisting hydrostatic and hydrodynamic loads and the effect of buoyancy. Dry floodproofing is allowed only where flood velocities are less than or equal to five (5) feet per second. A registered professional engineer or architect shall certify that the standards of this subsection are satisfied. A flood emergency operation plan and an inspection and maintenance plan must be provided by the design professional for the building. Such certification shall be provided to the floodplain administrator as set forth in section 6-21. New development proposals will be designed, to the maximum extent practicable, so non-residential building sites, walkways, driveways, and roadways are located at natural grade with elevation not less than the base flood elevation and with evacuation routes leading directly out of the special flood hazard area.
(3) In special flood hazard areas with base flood elevations (AE Zones) but without floodways, no encroachments, including fill material or structures, shall be permitted unless certification by a registered professional engineer is provided demonstrating that the cumulative effect of the proposed development, when combined with all other existing and anticipated development, will not increase the water surface elevation of the base flood more than one (1) foot at any point within the community. The engineering certification must be supported by technical data that conforms to standard hydraulic engineering principles.
(4) Enclosures. New construction or substantial improvements of elevated buildings that include fully enclosed areas formed by foundation and other exterior walls below the lowest floor shall be designed to preclude finished living space and designed to allow for the entry and exit of floodwaters to automatically equalize hydrostatic flood forces on exterior walls. Total enclosed area shall be limited to 299 square feet. Enclosed areas, including crawl spaces, shall be used only for parking of vehicles, building access, and storage.
a. Designs for complying with this requirement must either be certified by a professional engineer or architect or meet the following minimum criteria:
1. Provide a minimum of two (2) openings on different sides of each enclosed area, If a structure has more than one (1) enclosed area below the base flood elevation, each shall have openings on exterior walls.
2. The total net area of all openings shall be at least one (1) square inch for every square foot of enclosed area, or the openings shall be designed and the construction documents shall include a statement that the design and installation will provide for equalization of hydrostatic flood forces on exterior walls by allowing for the automatic entry and exit of flood waters;
3. The bottom of all openings shall be no higher than one (1) foot above foundation interior grade (which must be equal to in elevation or higher than the exterior foundation grade); and
4. Openings shall allow the passage of a three-inch sphere.
5. Openings may be equipped with screens, louvers, valves or other coverings or devices provided they permit the automatic flow of floodwaters in both directions, and automatically equalize hydrostatic flood loads on exterior walls, and;
b. Access to the enclosed area shall be minimum necessary to allow for parking of vehicles (garage door) or limited storage of maintenance equipment used in connection with the premises (standard exterior door) or entry to the living area (stairway or elevator); and
c. The interior portion of such enclosed area shall not be partitioned or finished into separate rooms.
d. Property owners shall be required to execute a flood opening/venting affidavit acknowledging that all openings will be maintained as flood vents, and that the elimination or alteration of the openings in any way will violate the requirements of section 6-31(4)
e. Detached storage buildings, sheds, or other like accessory improvements, excluding detached garages, carports, and boat houses, shall solely be used for parking of vehicles and storage, and will be allowed no more than six hundred (600) square feet of unfinished, non-partitioned and enclosed storage space. Such storage space shall not be used for human habitation and shall be limited to storage of items that can withstand exposure to the elements and have a low flood damage potential. The storage space shall be constructed of flood resistant or breakaway materials, and equipment and service utilities, such as electrical outlets, shall be limited to essential lighting and other incidental uses, and must be elevated or floodproofed. Flood openings in accordance with the standards of section 6-31(4) shall also be required. These accessory structures shall be constructed and placed on the building site so as to offer the minimum resistance to the flow of floodwaters. Accessory improvements and other appurtenant structures shall be firmly anchored to prevent flotation that may result in damage to other structures.
f. Where elevation requirements exceed six (6) feet above the highest adjacent grade, a copy of the legally recorded deed restriction prohibiting the conversion of the area below the lowest floor to a use or dimension contrary to the building's originally approved design, shall be presented as a condition of issuance of the final certificate of occupancy.
(5) Standards for manufactured homes and recreational vehicles.
a. All manufactured homes placed, or substantially improved, on individual lots or parcels, in existing manufactured home parks or subdivisions, in expansions to existing manufactured home parks or subdivisions, in new manufactured home parks or subdivisions or in substantially improved manufactured home parks or subdivisions, must meet all the requirements for new construction, including elevation and anchoring and the flood opening requirements of subsection 4. Manufactured homes must be:
1. Securely anchored to an adequately anchored foundation system to resist flotation, collapse and lateral movement, and
2. Elevated on a permanent foundation to have its lowest floor elevated to no lower than eighteen (18) inches above the level of the base flood elevation.
b. Excepting manufactured homes that have incurred substantial damage as a result of a flood, all manufactured homes placed or substantially improved in an existing manufactured home park or subdivision must be elevated so that:
1. The lowest floor of the manufactured home is elevated no lower than eighteen (18) inches above the level of the base flood elevation; and be securely anchored to an adequately anchored foundation support system to resist flotation, collapse and lateral movement, or
2. The manufactured home chassis is supported by reinforced piers or other foundation elements of at least an equivalent strength, of no less than thirty-six (36) inches in height above the highest adjacent grade and adequately anchored foundation support system to resist floatation, collapse, and lateral movement.
c. All recreational vehicles placed on sites must either:
1. Be on site for fewer than ninety (90) consecutive days; and shall leave the site for at least seven (7) consecutive days and obtain a new permit before returning to the same site,
2. Be fully licensed and ready for highway use; or
3. Must meet all the requirements for new construction, including anchoring and elevation requirements of section 6-31(5).
A recreational vehicle is ready for highway use if it is licensed and insured in accordance with the State of Mississippi motor vehicle regulations, is on its wheels or jacking system, is attached to the site only by quick disconnect type utilities and security devices and has no permanently attached additions.
(6) Floodways. Located within areas of special flood hazard established in section 6-11 are areas designated as floodways. Since the floodway is an extremely hazardous area due to the velocity of flood waters which carry debris, potential projectiles and has erosion potential, the following provisions shall apply:
a. Prohibit encroachments, including fill, new construction, placement of manufactured homes, substantial improvements and other developments.
b. Permissible uses within the floodway may include: general farming, pasture, outdoor plant nurseries, horticulture, forestry, wildlife sanctuary, game farm, and other similar agricultural, wildlife, and related uses. Also, lawns, gardens, athletic fields, play areas, picnic grounds, and hiking and horseback riding trails are acceptable uses, provided that they do not employ structures or fill. These permissible uses may require certification (with supporting technical data) by a registered professional engineer demonstrating that encroachments shall not result in any increase in flood levels during occurrence of the base flood discharge. The uses in this subsection are permissible only if and to the extent that they do not cause any increase in flood levels during the base flood discharge.
(Ord. of 3-4-03; Res. of 4-15-14(1), eff. 5-5-14)