§ 18.68.027 — Analysis and design
Long Beach Municipal Code (Supp. No. 53, Update 1: codified through Ordinance No. ORD-26-0027, enacted October 13, 2026) · Long Beach Municipal Code § 18.68.027
Corpus is an independent public-information project, not the official City of Long Beach website. Stable reference: corpuslaw.us/code/e8945095-9af0-4fb9-9616-2ce920dfb9ff
18.68.027 - Analysis and design.
A. General. Except as modified herein, the analysis and design relating to the structural alteration of existing buildings shall be in accordance with this title. B. Selection of procedure. Buildings shall be analyzed by the general procedure of Subsection 18.68.027.C which is based on UBC Chapter 23 or, when applicable, buildings may be analyzed by the special procedure of Subsection 18.68.027.D. C. General procedure. 1. Basis for design. The minimum design seismic forces shall be those determined in accordance with the static lateral force procedure of Subsection 18.68.027.C.1 or the dynamic lateral force procedure of Subsection 18.68.027.C.2. Minimum design lateral forces - static force procedure. Buildings shall be analyzed to resist minimum lateral forces assumed to act nonconcurrently in the direction of each of the main axes of the structure in accordance with the following: V B = φ ß CW (027-1) where V B = Design base shear W = Total seismic dead load of the building ß = Building type coefficient given in Table A-23-E φ = Occupancy Load Factor from Table A-23-F C = 0.059/ T 2/3 T = Building period, in seconds, of the structure in the direction of consideration The product of φ ß C need not exceed 0.13. The building period may be calculated in accordance with the 1988 UBC Method A or Method B. The value of C need not exceed 0.13. The distribution of the design base shear over the height of the building is to be the same as that specified by the 1988 UBC. 2. Minimum design lateral forces—Dynamic force procedure. Dynamic analysis procedures when used to determine the seismic demand on the building shall conform with Chapter 23 of the 1988 UBC. Except where approved situs specific response spectra are developed, ground motions used in the analysis shall be consistent with the October 1988 Seismic Safety Element to the City of Long Beach general plan and applied as follows: a. If the analysis utilizes the modal superposition spectral response approach, the five percent (5%) damped spectrum for the appropriate soil at the building site shall be used as the input ground motions. The response of the building shall be normalized by the ratio of the base shear determined from the equivalent static force approach to the base shear determined from the spectral response approach. b. If the analysis utilizes a time history (linear elastic or nonlinear) approach, an approved synthetic acceleration time history shall be constructed which is consistent with the five percent (5%) damped spectrum for the appropriate soil at the building site. Such an acceleration time history must have a response spectrum which closely matches the five percent (5%) damped spectrum with no spectral ordinate dipping more than ten percent (10%) below the target spectrum. 3. Lateral forces on elements of structures. Parts or portions of structures shall be analyzed as required in UBC Chapter 23. EXCEPTIONS: a. Unreinforced masonry walls for which height to thickness ratios do not exceed ratios set forth in Table A-23-B need not be analyzed for out-of-plane loading. Unreinforced masonry walls which exceed the allowable h/t ratios of Table A-23-B shall be braced according to Subsection 18.68.028.E. b. Parapets complying with Subsection 18.68.028.F need not be analyzed for out-of-plane loading. 4. Shear walls (in-plane loading). Shear walls shall comply with Subsection 18.68.027.E. D. Special procedure. 1. Limits for the application of Subsection 18.68.027.D. The special procedure of this subsection may only be applied to buildings with the following characteristics: a. Flexible diaphragms at all levels above the base of structure. b. A maximum of six (6) stories above the base of the building. c. The vertical elements of the lateral force resisting system shall consist predominately of masonry or concrete shear walls. d. New vertical elements of the lateral force resisting system consisting of steel braced frames or special moment resisting frames shall have a maximum overall height-to-length ratio of 1.5 to 1. e. A minimum of two (2) lines of vertical elements of the lateral force resisting system parallel to each axis of the building except for single story buildings with an open front on one (1) side only. (See Subsection 18.68.027.D.8 for open front buildings.) 2. Lateral forces on elements of structures. With the exception of the diaphragm provisions in Subsection 18.68.027.D, elements of structures shall comply with Subsection 18.68.027.C.3. 3. Crosswalls. Crosswalls shall meet the requirements of this subsection. a. Crosswall definition. A crosswall is a wood-framed wall sheathed with any of the materials described in Tables A-23-C or A-23-D. Spacing of crosswalls shall not exceed forty (40) feet on center measured perpendicular to the direction of consideration, and shall be placed in each story of the building. Crosswalls shall extend the full story height between diaphragms. EXCEPTIONS: i. Crosswalls need not be provided at all levels in accordance with Subsection 18.68.027.D.4.b.iv. ii. Existing crosswalls need not be continuous below a wood diaphragm at/or within four feet of grade provided: aa. Shear connection requirements of Subsection 18.68.027.D.5 are satisfied at all edges of the diaphragm. bb. Crosswalls with total shear capacity of 0.08 (W d interconnect the diaphragm to the foundation. cc. The demand/capacity ratio of the diaphragm between the crosswalls that are continuous to their foundations shall be calculated as: DCR = [0.33W D + V ca ]/2v u D (027-2) and DCR shall not exceed 2.5. b. Crosswall shear capacity. Within any forty (40) feet measured along the span of the diaphragm, the sum of the crosswall shear capacities shall be at least thirty percent (30%) of the diaphragm shear capacity of the strongest diaphragm at or above the level under consideration. c. Existing crosswalls. Existing crosswalls shall have a length to height ratio between openings of not less than 1.5. Existing crosswall connections to diaphragms need not be investigated as long as the crosswall extends to the framing of the diaphragm above and below. d. New crosswalls. New crosswall connections to the diaphragm shall develop the crosswall shear capacity. New crosswalls shall have the capacity to resist an overturning moment equal to the crosswall shear capacity times the story height. Crosswall overturning moments need not be cumulative over more than two (2) stories. e. Other crosswall systems. Other systems such as special moment resisting frames may be used as crosswalls provided that the yield story drift does not exceed one (1) inch in any story. 4. Wood diaphragms. a. Acceptable diaphragm span. A diaphragm is acceptable if the point (L, DCR) on Figure A-23-1, falls within Regions 1, 2, or 3. b. Demand-capacity ratios. Demand-capacity ratios shall be calculated for the diaphragm according to the following formulas: i. For a diaphragm without qualifying crosswalls at levels immediately above or below: DCR = 0.33W d /Σ v u D(027-3) ii. For a diaphragm in a single-story building with qualifying crosswalls: DCR = 0.33W d /Σ v u D + V cb )(027-4) iii. For diaphragms in a multi-story building with qualifying crosswalls in all levels: DCR = 0.33 W d /Σ v u D + V cb )(027-5) DCR shall be calculated at each level for the set of diaphragms at and above the level under consideration. iv. For a roof diaphragm and the diaphragm directly below if coupled by crosswalls DCR = 0.33( W d /Σ v u D(027-6) v. Chords. An analysis for diaphragm flexure need not be made and chords need not be provided. vi. Collectors. An analysis of diaphragm collector forces shall be made for the transfer of diaphragm edge shears into vertical elements of the lateral force resisting system. Collector forces may be resisted by new or existing elements. vii. Diaphragm openings. viii. Diaphragm forces at corners of openings shall be investigated and shall be developed into the diaphragm by new or existing materials. ix. In addition to calculating demand capacity ratios per Subsection 18.68.027.D.4.b, the demand capacity ratio of the portion of the diaphragm adjacent to an opening shall be calculated using the opening dimension as the span. x. Where an opening occurs in the end quarter of the diaphragm span, the quantity v u d for the demand capacity ratio calculation shall be based on the net depth of the diaphragm. 5. Shear transfer. Diaphragms shall be connected to shear walls with connections capable of developing a minimum force given by the lesser of the following formulas: V = 0.20C p W d (027-7) using the C p values in Table A-23-A, or V=v u D(027-8) 6. Shear walls (in plane loading)—Special procedure. a. Wall story force. The wall story force distributed to a shear wall at any diaphragm level shall be the lesser value calculated as: i. For buildings without crosswalls, F wx = 0.13(W wx + W d /2)(027-9) but need not exceed F wx = 0.13W wx + v u D(027-10) ii. For buildings with crosswalls in all levels: F wx = 0.10(W wx + W d /2)(027-11) but need not exceed F wx = 0.10(W wx + Σ W d (v u D/ Σ v u D))(027-12) and need not exceed F wx = 0.10W wx + v u D(027-13) b. Wall story shear. The wall story shear shall be the sum of the wall story forces at and above the level of consideration. V wx = Σ F wx (027-14) c. Shear wall analysis. Shear walls shall comply with Subsection 18.68.027.E. d. Moment frames. Moment frames used in place of shear walls shall be designed as required in UBC Chapter 23 except that the forces shall be as specified in Subsection 18.68.027.D.6.a and the interstory drift shall be limited to 0.005 except as further limited in Subsection 18.68.027.E.3.b. 7. Out of plane forces—URM walls. a. Allowable URM wall height to thickness ratios. The provisions of Subsection 18.68.027.C.3 are applicable except the allowable h/t ratios given in Table A-23-B shall be determined from Figure A-23-1 as follows: i. In Region 1, h/t ratios for "buildings with crosswalls" may be used if qualifying crosswalls are present in all stories. ii. In Region 2, h/t ratios for "buildings with crosswalls" may be used whether or not qualifying crosswalls are present. iii. In Region 3, h/t ratios for "all other buildings" shall be used whether or not qualifying crosswalls are present. b. Walls with diaphragms in different regions. When diaphragms above and below the wall under consideration have DCRs in different regions of Figure A-23-1, the lesser h/t ratio shall be used. 8. Buildings with open fronts. A building with an open front on one (1) side shall have crosswalls parallel to the open front and shall be designed by the following procedure: a. Effective diaphragm span, L i , for use in Figure No. A-23-1 shall be determined in accordance with the following formula: L i , = 2[(W w /W d ) • L + L](027-15) b. Diaphragm demand/capacity ratio shall be calculated as: DCR = 0.33(W d + W w )/[(v u D) + V c ](027-16) E. Analysis of vertical elements of the lateral force-resisting system. Applicable to both general procedure and special procedure buildings. 1. Existing URM walls. a. Flexural rigidity. Flexural components of deflection may be neglected in determining the rigidity of a URM wall. b. Shear walls with openings. Wall piers shall be analyzed according to the following procedure: i. For any pier: aa. The pier shear capacity shall be calculated as: V a = v a Dt(027-17) bb. The pier rocking shear capacity shall be calculated as: V r = 0.5P D D/H(027-18) ii. The wall piers at any level are acceptable if they comply with one of the following modes of behavior: aa. Rocking controlled mode. When the pier rocking shear capacity is less than the pier shear capacity, i.e. V r < V a for each pier in a level, forces in the wall at that level, V wx, shall be distributed to each pier, V p , in proportion to P D D/H. For the wall at that level: V wx < V r (027-19) bb. Shear controlled mode. Where the pier shear capacity is less than the pier rocking capacity, i.e., V a < V r in at least one pier in a level, forces in the wall at that level, V wx, shall be distributed to each pier, V p , in proportion to D/H. For each pier at that level: V p < V a (027-20) and V p < V r. (027-21) If V p > V a for each pier and V p > V r for one or more piers, omit such piers from the analysis and repeat the procedure for the remaining piers, or strengthen and reanalyze the wall. iii. Masonry pier tension stress. Unreinforced masonry wall piers need not be analyzed for tension stress. c. Shear walls without openings. Shear walls without openings shall be analyzed as for walls with openings except that V r, shall be calculated as follows: V r = (0.50P D + 0.25P W )D/H(027-22) 2. Plywood sheathed shear walls. Plywood sheathed shear walls may be used to resist lateral loads for buildings with flexible diaphragms analyzed according to provisions of Subsection 18.68.027.C. Plywood sheathed shear walls may not be used to share lateral loads with other materials along the same line of resistance. 3. Combinations of vertical elements. a. Lateral force distribution. Lateral forces shall be distributed among the vertical resisting elements in proportion to their relative rigidities, except that moment frames shall comply with Subsection 18.68.027.E.3.b. b. Moment resisting frames. A moment frame shall not be used with a URM wall in a single line of resistance unless the wall has piers that are capable of sustaining rocking in accordance with Subsection 18.68.027.E.1.b and the frames are designed to carry one hundred percent (100%) of the lateral forces and the interstory drift ratio shall be limited to 0.0025.
(ORD-25-0019 § 1(Exh. A), 2025; ORD-22-0033 § 1(Exh. A), 2022; ORD-19-0031 § 1(Exh. A), 2019; ORD-16-0026 § 1(Exh. A), 2016)
Ask a question about Long Beach law
Corpus searches the Long Beach sections it holds and shows the ones that match, with their citations. Free, no sign-in.
