R310 — EMERGENCY ESCAPE AND RESCUE OPENINGS

The Philadelphia Code (2026 Code: The Philadelphia Code and Home Rule Charter current through October 8, 2026) · Philadelphia Code Subcode R, § R310

Corpus is an independent public-information project, not the official City of Philadelphia website. Stable reference: corpuslaw.us/code/f0c3d9cb-3ad5-479d-96e5-b043f38e3e49

SECTION R310 EMERGENCY ESCAPE AND RESCUE OPENINGS

* * * [Pursuant to the UCC, delete Section R310.1 and replace as follows:] R-R310.1 Emergency escape and rescue opening required. Basements, habitable attics and every sleeping room shall have not less than one operable emergency escape and rescue opening. Where basements contain one or more sleeping rooms, an emergency escape and rescue opening shall be required in each sleeping room. Emergency escape and rescue openings shall open directly into a public way, or to a yard or court having a minimum width of 36 inches (914 mm) that opens to a public way. Exceptions: 1. Storm shelters and basements used only to house mechanical equipment not exceeding a total floor area of 200 square feet (18.58 m2). 2. Where the dwelling unit or townhouse unit is equipped with an automatic sprinkler system installed in accordance with Section P2904, sleeping rooms in basements shall not be required to have emergency escape and rescue openings provided that the basement has one of the following: 2.1. One means of egress complying with Section R311 and one emergency escape and rescue opening. 2.2. Two means of egress complying with Section R311. 3. A yard shall not be required to open directly into a public way where the yard opens to an unobstructed path from the yard to the public way. Such path shall have a width of not less than 36 inches (914 mm). 4. Properties with in-fill lots that are sprinklered in accordance with Section 2904, and a minimum clear yard size of 80 sq ft (7.43 m2) shall be allowed to have access to the public way provided by a shared easement that is a minimum of 30 in (762 mm) wide. * * * [Delete R310.7 and replace as follows, but retain R310.7.1:] R-R310.7 Alterations or repairs of existing basements. An emergency escape and rescue opening is not required for existing basements undergoing alterations or repairs, where such alterations or repairs do not increase the existing story height of the basement. Exception: New sleeping rooms created in an existing basement shall be provided with emergency escape and rescue openings in accordance with Section R310.1. * * *

Ask a question about Philadelphia law

Corpus searches the Philadelphia sections it holds and shows the ones that match, with their citations. Free, no sign-in.