3.3. - Preliminary plat.
(1) Application procedure. Based upon the planning commission's approval of the layout, the owner or his representative shall file an application for approval of a preliminary plat. Where required, the application for approval of a preliminary plat shall:
A. Be made on forms available at the office of the manager of planning.
B. Include payment of an application fee of $100.00 plus $5.00 per proposed lot.
C. Be accompanied by a minimum of three copies of the preliminary plat as described in these regulations and complying in all respects with these regulations.
D. Be accompanied by one set of all certified construction plans to include the preliminary plat as described in these regulations and complying in all respects with these regulations.
E. Be accompanied by a minimum of three copies of the geotechnical investigation and testing report as described in these regulations and complying in all respects with these regulations.
F. Be presented to the manager of planning sufficiently in advance of the meeting of the subdivision committee of the planning commission to allow time for his review.
G. Be accompanied by digital submittal of the preliminary plat and construction plans to Geographic Information and Mapping Services (G.I.M.S.), in compliance with all preliminary plat requirements, along with electronic notification to the following divisions: planning, engineering, Huntsville utilities, and Geographic Information and Mapping Services (G.I.M.S.).
(2) Public hearing. The planning commission shall hold a public hearing on the preliminary plat prior to approval of said preliminary plat as required for plats under Alabama Law.
(3) Preliminary plat requirements. Unless otherwise specified, all plans and reports submitted as part of the application shall be submitted as separate documents and shall be drawn to a convenient scale of not more than 100 feet to an inch, on sheet size not larger than 24″ × 36″. The preliminary plat shall include the following information:
A. Names and addresses of the owner of the land to be subdivided, the subdivider (if other than the owner), the engineer and surveyor.
B. Geodetic control and references which shall include the following:
(i) Tie points to a minimum of two accepted GPS monuments or one GPS tie point plus an astronomic observation to determine grid north.
(ii) Tie points to an accepted corner based on the U.S. Government Public Lands Survey System which shall show the relationship to the Huntsville Meridian.
(iii) All existing monuments, proposed monuments, corners and points required under article [subsection] 4.4 shall be noted and shown on the plat.
(iv) State plane coordinates on all monuments specified in article [subsection] 4.4(2) based on NAD 1983 [North American Horizontal Datum], and Alabama East Zone as described in the Code of Ala. 1975, § 35-2-1.
(v) North arrows indicating grid north.
C. Exact boundary lines of the tract indicated by a heavy line giving distances to the nearest hundredth of a foot and bearings to the nearest second of arc. Field data for all monuments shall achieve a ratio of precision (closure) of 1:10,000 or better.
D. Lot lines with distances to the nearest hundredth of a foot, bearings and angles sufficient to reproduce the survey and chords and radii of rounded corners.
E. Street centerlines and geometrics showing angles of deflection or bearing, angles of intersection, curve radii, length of tangents and centerline stationing.
F. Widths of existing and proposed right-of-way, including dimension from centerline of all existing right-of-way to the subdivision boundary and a clear indication of location and width of right-of-way of any street adopted as a part of the major street plan.
G. Location and description of all required sidewalks and off-street pedestrian walkways.
H. The date of the map, scale and title of the subdivision.
I. Name of all the streets.
J. Building setback line, locations and depths.
K. Lot and block numbers. Blocks shall be consecutively numbered or lettered in alphabetical order. Lots within each block shall be consecutively numbered.
L. Easements, buffer strips and public service utility rights-of-way lines giving widths, locations, and purposes.
M. Accurate outlines and descriptions of any areas to be dedicated or reserved for public use or acquisition with the purpose indicated thereon; and of any areas to be reserved by deed covenant for common use of all property owners.
N. Acreage and number of lots within the subdivision.
O. A lot data box as shown below:
LOT DATA
BLOCK NUMBER | LOT NUMBER | AREA IN SQUARE FEET
P. Floodway and floodway fringe boundaries within the subdivision. If within the 100 year flood plain the lowest allowable finished floor elevation for each lot, based on officially adopted floodway regulations of the City of Huntsville.
Q. Key map where more than one sheet is required to present map.
R. All surveys and plats must be done in accordance with the current "Minimum Technical Standards for Land Surveying in Alabama," as adopted by the Alabama Society of Professional Land Surveyors.
S. Digital Formats-CADD/CAM files shall be submitted in a DGN, DXF, or DWG file format. Electronic notification letters shall consist of a list of files being submitted, a description of the data in each file, a level/layer schematic of each design file, and a statement conveying rights to the City of Huntsville for the data to be used for G.I.M.S. purposes. DGN design files shall have working units as follows: master units in feet, no subunits, and 1,000 positional units. All data submitted shall use NAD 1983 Alabama East Zone coordinates as described in The Code of Ala. 1975, § 35-2-1 and NGVD 1929 [National Geodetic Vertical Datum]. Digital files must display, by text, said state plan coordinates for all points specified in article [subsection] 4.4(2). Digital submission - Digital files shall be submitted to Geographic Information and Mapping Services (G.I.M.S.) by 4¾″ CD ROM, 100 MB zip drive, 3½ inch floppy disk, or to the City of Huntsville F.T.P. site.
(4) Construction plans. For all subdivisions proposing improvements requiring construction approval, the following shall be submitted. Each plan and any map required with report shall include the base information listed below:
A. Base information:
(i) The date of the map, a reference meridian (designated on the plat either true or magnetic north), scale, title of the subdivision.
(ii) Exact boundary lines of the tract indicated by a heavy line, or other acceptable control traverse, giving distances to the nearest hundredth of a foot and bearings to the nearest second of arc.
(iii) Lot lines without distances to the nearest hundredth of a foot, bearings and angles and chords and radii of rounded corners.
(iv) Lot and block numbers.
(v) Building setback line, locations and depths.
(vi) Street centerlines and rights-of-way including centerline stationing.
(vii) Easements, buffer strips and public service utility rights-of-way lines giving widths, locations, and purposes.
(viii) Accurate outlines and descriptions of any other areas to be dedicated or reserved for public use or acquisition with the purpose indicated thereon; and of any areas to be reserved by deed covenant for common use of all property owners.
B. Geotechnical investigation and testing report. Where construction is proposed on lands or portions of land where colluvium, evidence of mine operations, Pennington, Pride or shaley Upper Bangor formations, dump sites or existing fill and excavation is present as indicated on the site assessment map or when in the professional opinion of the geotechnical engineer of record, geotechnical testing should be performed, a "Geotechnical Investigation and Testing Report" shall be submitted containing the following:
(i) Names and qualifications of all investigators involved with the geotechnical investigation.
(ii) Methods used in the performance of all site investigations and tests as described in the geotechnical investigation and testing plan.
(iii) Findings of all performed site investigations and tests keyed to a map to be at the same size and scale as the preliminary plat including clear indication of all hazard zone lands as defined by the Zoning Ordinance of the City of Huntsville, Alabama.
(iv) Conclusions as to how the findings will impact the proposed improvements.
(v) Recommendations for mitigating all located and described on-site hazards and sensitive environmental features.
(vi) The following certifications:
I, ___________, the engineer of record, do hereby certify that the information shown hereon is complete and correct and in compliance with all applicable regulations of the City of Huntsville, Alabama, to the best of my knowledge.
_____ Date | _____ Engineer of Record
Due to the documented evidence of potential geologic/man-made hazards existing on or near the lots shown hereon, I, ___________, the geotechnical engineer of record, having caused investigations and tests to be performed and based on the findings of said investigations and tests do hereby certify that all lots shown hereon exhibit no apparent geologic or geotechnical constraints which would render said lots unfit for development.
_____ Date | _____ Geotechnical Engineer of Record
For development where construction is proposed on lands or portions of lands which are designated as hazard zone as defined by the Zoning Ordinance of the City of Huntsville, Alabama, the following certifications:
ENGINEER OF RECORD
I, ___________, the engineer of record, certify that the proposed development shown hereon is designed in accordance with sound engineering standards and practices, and in accordance with all applicable development regulations. I further certify that I have caused prudent investigation, testing and inspections to be performed on all lands within the proposed development identified as hazard zone, as defined by the Zoning Ordinance of the City of Huntsville, Alabama, including geotechnical analysis and testing on all hazard zone lands and on lands upslope and downslope of the proposed development, and I have instructed the land surveyor as to those areas within the proposed development that fall within the hazard zone for inclusion in the development plats. Based upon the investigation, testing and inspections performed, as defined and discussed in the geotechnical analysis and report dated ________ and submitted in connection herewith, and further based upon any remedial measures taken in connection with the hazards defined therein, I certify that, within acceptable geotechnical standards, development of the property as shown on the plat will not diminish the stability of the slope or otherwise increase the likelihood of landslide or other slope failure and that the buildable areas designated hereon can meet a minimum safety factor of 1.5 for stability.
_____ Date | _____ Engineer of Record
OWNER
I, ___________, owner/owners of the lands embraced hereon, hereby certify that I have caused investigation in accordance with sound engineering standards and practice to be made of hazard zone lands, as defined by the Zoning Ordinance of the City of Huntsville, Alabama, within the development as shown hereon. I further understand the potential and inherent danger of said lands and that landslides have originated in conditions that regularly exist on said hazard zone lands.
With this knowledge, I hereby certify that I have caused all prudent measures to be taken in the design of the development as shown hereon, including an analysis of all lands upslope and downslope of the hazard zone lands, to assure that the site is safe for the proposed development, and within acceptable geotechnical standards the proposed development will not diminish the stability of the slope or otherwise increase the likelihood of landslide or other slope failure.
_____ Date | _____ Owner
C. Vegetation plan. When a buffer planting and/or screen planting is required, the following information shall be submitted:
(i) Location and description of all proposed plants.
(ii) Plant schedule indicating botanical name, common name, quantity, size and condition of all proposed plants.
(iii) Typical planting details including typical plan and cross section.
D. Grading and erosion and sedimentation control plan. The grading and erosion and sedimentation control plan shall be in compliance with the "City of Huntsville Stormwater Management Manual" and all other applicable regulations of the City of Huntsville and shall include:
(i) All information shown shall be drawn at same sheet size and scale as the preliminary plat.
(ii) All existing and proposed improvements within 200 feet of the proposed subdivision, including but not limited to streets, drainage structures, ditches, manholes, utility lines, etc.
(iii) All existing contours indicated by broken (dashed) lines and all proposed contours indicated by solid lines at a minimum interval of two feet except where slopes exceed 15 percent in which case a minimum interval of five feet shall be shown.
(iv) The elevation of all known high water marks or flood lines as well as the elevation of all proposed structures, including finished floor elevations of all buildings.
(v) Bench mark, including elevation, relative to national geodetic vertical datum.
(vi) The slope of all proposed excavation and fill embankments.
(vii) Approximate location, description and details of all proposed retaining structures for excavation and fill slopes in excess of two feet horizontal to one foot vertical.
(viii) Location, description and details of all temporary and permanent erosion and sedimentation control measures to be utilized including, but not limited to, silt fences, silt dikes, hay bale dikes, construction entrances, siltation ponds, permanent ground cover types and application rates.
(ix) Implementation schedule of all erosion and sedimentation control measures for construction of temporary and permanent control measures and final stabilization.
(x) The following certifications:
I, ___________, the engineer of record, do hereby certify that the information shown hereon is complete and correct and in compliance with all applicable regulations of the City of Huntsville, Alabama, and that proposed grading as shown hereon complies with good engineering practice and further do certify that all erosion and sedimentation control measures as indicated hereon are designed to minimize the effects of erosion and sedimentation on site.
_____ Date | _____ Engineer of Record
I, ___________, City Engineer for the City of Huntsville, Alabama, approve of the design and the construction plans for grading and erosion and sedimentation control as shown in these plans.
_____ Date | _____ City Engineer City of Huntsville, Alabama
E. The street plan. The street plan shall be in compliance with the "City of Huntsville Stormwater Management Manual" and all other applicable regulations of the City of Huntsville. The street plan shall be comprised of plan views and profiles of all proposed streets, cross sections of all proposed streets, and a typical cross section detail.
(i) The plan view and profile map(s) shall be drawn at a horizontal scale not to exceed 50 feet to the inch and a vertical scale not to exceed ten feet to the inch and shall include:
a. Location of existing or proposed streets adjacent to the subdivision, including all curb cuts, driveways, or intersections along both sides of boundary streets adjacent to the subdivision.
b. Widths of existing and proposed rights-of-way.
c. Street names to be approved by the planning commission.
d. Locations and specifications of all required traffic control devices and street name signs.
e. Topography at two-foot intervals unless a closer contour interval is required by the city engineer. In cases where slopes exceed 15 percent, a minimum contour interval of five feet may be shown.
f. Location and description of all required sidewalks and off-street pedestrian walkways.
g. Horizontal curve data from the centerline of each street: delta, angle, tangent and radius.
h. Vertical curve data including grades, elevations, point of vertical curvature, point of vertical intersection and tangents.
i. A table relative to sight distance affixed to the construction drawings following the format below:
Location | Direction | Sight Distance
Controlling Element | Design Speed | AASHTO Guidelines
j. Certificates executed as shown below:
"STREET SYSTEM"
To be certified by the engineer of record that the sight distance at any new street intersection meets the minimum AASHTO standards.
I, (Engineer of Record), Registered Engineer, certify that the intersection sight distance of any roadway constructed in conjunction with this subdivision meets or exceeds specifications as set forth in the prevailing AASHTO Standards to the best of my knowledge and belief.
_____ Date | _____ Engineer of Record Registration Number
I, ___________, the engineer of record, certify that the street system shown on this drawing meets the construction standards of the City of Huntsville and conforms to the design standards of the Huntsville Subdivision Regulations and applicable AASHTO geometric design policy. It is certified that the information shown hereon is true and correct to the best of my knowledge.
_____ Date | _____ Engineer of Record Registration Number
I, ___________, the City Engineer for the City of Huntsville, Alabama, approve of the design and the construction plans of the street system as shown in these plans.
_____ Date | _____ City Engineer City of Huntsville, Alabama
I, ___________, the Traffic Engineer for the City of Huntsville, Alabama, concur in the geometric design of the street system and the use of the street name(s) as shown in this drawing.
_____ Date | _____ Traffic Engineer City of Huntsville, Alabama
(ii) The cross sections of all streets shall be shown at a minimum interval of 50 feet. The horizontal scale shall not exceed ten feet to the inch and the vertical scale shall not exceed ten feet to the inch.
(iii) Typical cross section details of all proposed streets shall be shown (may be shown on detail sheet).
F. The stormwater drainage and sanitary sewer plan. The drainage and sanitary sewer plan shall be in compliance with the "City of Huntsville Stormwater Management Manual" and all other applicable regulations of the City of Huntsville and shall be accompanied by drainage area contour maps of not more than 400 feet to an inch showing the entire tributary area and separate drainage areas for each proposed drainage facility as well as a signed and sealed copy of all engineering calculations and notes used in the design of the storm drainage system. Drainage concentrations shall be indicated on the drainage area contour maps. The detailed storm drainage and sanitary sewer plan shall be prepared from an actual engineering survey and be drawn to a scale of not more than 50 feet to an inch. The detailed storm drainage and sanitary sewer plan shall show:
(i) All existing improvements within and bordering the proposed subdivision, including flood hazard districts, the location and size of all existing and proposed sanitary sewers in the subdivision, clear indication of sanitary sewer tie points of the subdivision and station location of all sewer laterals.
(ii) The proposed street plan and associated drainage system.
(iii) Designation of each drainage area and design flow for each storm drainage pipe or drainage facility.
(iv) Typical cross sections of each drainage way.
(v) Lengths of pipes of drainage facilities, slopes, facility sizes, materials, locations of inlets, manholes, junction boxes, and all information relative to the comprehensive drainage system including as much as is practical of the offsite drainage systems affected by the proposed subdivision.
(vi) Where fill is to be placed within flood fringe areas, a grading plan showing final elevations.
(vii) Profiles of the storm drainage and sanitary sewerage system drawn on cross-section or plan/profile paper at a scale not greater than 1″ = 50′ horizontal and 1″ = 10′ vertical showing slopes, facility sizes, materials, sanitary sewer crossings, and all other information pertinent to the storm drainage system and sanitary sewer system (may be included with street profiles on street plan/profile map).
(viii) Type, size and slope of sanitary sewer and storm drainage pipe, bedding details, direction of flow of each sewer and storm drainage line, and specifications for excavation, backfill, compaction and testing.
(ix) Location of each manhole and other sewerage system appurtenances including lift stations, oxidation ponds, treatment plants, etc.
(x) Engineering details of drainage structures and each sanitary sewer manhole and other sewerage system appurtenances including lift stations, oxidation ponds, treatment plants, etc. (may be placed on detail sheets).
(xi) Proposed on-site sanitary sewer treatment facilities, whether privately owned or publicly dedicated, must meet all the design and performance standards as established for such facilities by the City Engineer of the City of Huntsville, Alabama.
(xii) Certificates executed as shown below:
"STORM DRAINAGE AND SANITARY SEWER SYSTEM"
I, ___________, the engineer of record, certify that the storm drainage and sanitary sewerage systems shown on this drawing is designed in accordance with the specifications of the City Engineer of the City of Huntsville, Alabama, and the Huntsville subdivision regulations. It is certified that the information shown hereon is true and correct to the best of my knowledge. It is further certified that adequate storm drainage easements are provided, where necessary.
_____ Date | _____ (Engineer of Record) Registration Number
I, ___________, the City Engineer for the City of Huntsville, Alabama, approve of the design and the construction plans of the storm drainage and sanitary sewerage systems as shown in these plans.
_____ Date | _____ City Engineer City of Huntsville, Alabama
"FLOOD HAZARD CERTIFICATE"
I, ___________, the engineer of record, certify that the subdivision shown hereon lies within flood hazard area as shown on the Federal Insurance Administration's Flood Insurance Rate Maps for
_____ (County/City) | _____ (State)
Firm Panel # _______
Dated _______
Based on the current designation of floodway and flood fringe as established and adopted by the City of Huntsville the minimum finished floor elevation shall be _______.
G. The septic tank plan (if applicable). Where no sanitary sewer system is available, a septic tank plan shall be prepared showing:
(i) Location and capacity of all septic tanks proposed within the subdivision.
(ii) Soil type according to county soil survey.
(iii) Depth of soil if less than six feet.
(iv) Location of percolation test holes and results of percolation tests.
(v) Location of tile field and minimum length of tile runs.
(vi) Certificates executed as shown below:
"SEPTIC TANKS"
I, ___________, the engineer of record or licensed land surveyor, certify that the percolation tests made above meet Health Department procedures and standards. I further certify that the above information is true and correct to the best of my knowledge.
_____ Date | _____ (Engineer of Record) Registration Number
From the septic tank information submitted to the _______ County Health Department for lots _____ of _______ Subdivision, the following recommendations are made:
a) Lots _____ meet _______ County Health Department requirements and should operate satisfactorily;
b) Lots _____ require further engineering and/or alternative septic system installation;
c) Lots were not tested.
Each lot or tract shall be investigated further and approved or disapproved on its own merits.
_____ Date | _____ Health Officer
_____ County, Alabama
H. Utilities, except natural gas. Each proposed subdivision shall receive a construction certification as described below for each of the following utility services requested:
County Water Authority
Huntsville Utilities Water Department
Huntsville Utilities Electric Department
Local Telephone Company
Local Cable TV Company
For each service requested, the engineer of record will provide the utility with a print and a reproducible copy of the proposed subdivision. The print will show: 1) elevations, 2) sanitary sewer, 3) storm drains, 4) sidewalks, 5) lot lines and measurements, 6) rights-of-way (with street names shown), 7) easements, 8) curbs and gutters, 9) lot and block numbers and 10) location of common trenches as required for subdivisions located within the slope development district as defined by the City of Huntsville Zoning Ordinance. The reproducible copy will show: 1) lot lines and measurements, 2) rights-of-way (with street names shown), 3) easements, and 4) lot and block numbers. For subdivisions requiring a geotechnical test, Huntsville Utilities will be provided with a copy of the Geotechnical Investigation and Testing Plan. Each utility from which service is requested shall provide the following certification on a copy of the preliminary plat or a set of related construction plans:
"(Name of Utility) SERVICE"
The _______ has reviewed the required submission material for the proposed subdivision in sufficient detail to determine that service can be made available. When improvements are completed, "as built" construction plans will be submitted to (the Huntsville Engineering Department).
_____ Date | _____ Name and Title Name of Utility
Additionally, for subdivisions in the slope development district as defined by the City of Huntsville Zoning Ordinance, each utility from which service is requested shall provide the following certificate on a copy of the preliminary plat or a set of related construction plans: The (utility service) approves of the location or the common trenches and the design and construction plans of the common trenches as shown in these plans.
_____ Date | _____ Name and Title Name of Utility
I. Natural gas. For proposed subdivisions not requesting natural gas service, the engineer of record will provide the natural gas department with prints and documents described in [subsection] 3.3(4)(H). After review of the prints, the natural gas department shall provide the following statement on a copy of the preliminary plat or a related set of construction plans:
"NATURAL GAS SERVICE"
The Natural Gas Department of Huntsville has reviewed the required submission material for the proposed subdivision in sufficient detail to determine that service (can or cannot) be made available. The applicant, at the present time, does not request natural gas service for this subdivision. The Natural Gas Department reserves the right to consider gas service for this subdivision in the future.
_____ Date | _____ Manager
J. Wells. For subdivisions not served by city or county water systems but where wells are proposed, a certificate as shown below shall be attached to a copy of the plat or a related set of construction plans showing the well locations.
"WELLS"
The location of wells as shown on this plat meets the requirements of the _______ County Health Department.
_____ Date | _____ Health Officer
| _______ County, Alabama
(5) Recertification of changed plans. Any changes in the construction plans, other than changes in the field approved by the city engineer, will require certification as for original approval.
(6) Study of preliminary plat. The subdivision committee shall consider the preliminary plat and construction plans and render a report to the next meeting of the planning commission concerning the preliminary plat.
(7) Preliminary plat approval. After the planning commission has reviewed the preliminary plat and construction plans, the report of the subdivision committee, public comments, and recommendations of involved agencies and officials, it shall approve or disapprove the preliminary plat.
(8) Effective period of preliminary approval. The approval of a preliminary plat shall be effective for a period of one year at the end of which time final approval on the subdivision must have been obtained from the planning commission, although the plat need not yet be signed and filed with the county judge of probate. Any plat not receiving final approval within the period of time set forth herein shall be null and void, and the developer shall be required to resubmit a new plat for preliminary approval subject to all new zoning restrictions and subdivision regulations.