For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 105-41 — Specifications

Milwaukee Code of Ordinances (Volumes 1-3 revised through Common Council action of Sept. 22, 2026) · Milwaukee Code of Ordinances § 105-41

Corpus is an independent public-information project, not the official City of Milwaukee website. Stable reference: corpuslaw.us/code/faee3aa8-99ac-4d8f-8be0-abbb1131a63a

105-41. Specifications.

1. USE AND CONSTRUCTION. The room, place or enclosure wherein the firing of firearms is to take place shall not be used for any other purpose whatsoever during the progress of firing. The rear wall and side walls in front of the firing line shall be made bullet proof and shall be of at least the following construction: a. 8 inch solid masonry or concrete. b. 10 inch hollow concrete block. c. Wood stud and plaster walls or equivalent construction covered with 1/4 inch steel plate and faced with wood one inch thick. 2. BULLET PROTECTING PLATES. a. When the floor construction is other than reinforced concrete and there is a room below, such floor in front of the firing line for a distance of at least 10 feet shall be covered with a steel plate not less than 1/4 inch in thickness. When there is no room below such floor, the thickness of such steel plate may be 1/16 inch in order to provide fire protection for unburned powder. b. When the ceiling construction is of other than reinforced concrete and there is a room above, such ceiling in front of the firing line for a distance of at least 10 feet shall be covered with a steel plate not less than 1/4 inch in thickness. c. Exposed pipes, conduits, beams, pilasters, columns, lights or any other projecting surface in front of the firing line shall be provided with protecting steel plates not less than 1/4 inch in thickness faced with wood 2 inches in thickness to prevent damage by stray bullets and to prevent injury to persons by ricocheting bullets. These plates shall be set at such an angle that no bullet can possibly return towards the firing point. 3. DOOR AND WINDOW OPENINGS. a. All door, window or other openings in the range, in front of the firing line, shall be protected with 1/4 inch steel plate faced with wood one inch thick. b. All doors opening into the range, except those behind the firing line, shall be bolted from the inside. 4. BULLET STOPS. a. The bullet stop shall consist of a steel plate placed at an angle of 45 and running the width of the range. When only .22 caliber ammunition is used, the plate shall be 3/8 inch thick if of structural steel or 1/4 inch thick if of armor plate. The thickness shall be increased to 1/2 inch structural steel or 3/8 inch armor plate if .38 caliber or .45 caliber ammunition is used. b. The plates of the bullet stop shall be butted tightly together and bolted to an angle or tee at the joints using countersunk heads on the face. Shiplap joints or welded joints can be used also. Targets should not be mounted in front of any joints. c. The side walls at the bullet stop shall be covered by 1/4 inch steel plate, not less than 2 feet wide, and slanting with the bullet stop to protect the walls from the splatter of lead. d. At the base of the inclined bullet stop there shall be provided a box, not less than 5 feet wide and running the width of the range, with not less than 6 inches of clean sand or sawdust to catch the deflected bullets. 5. TARGETS. a. Targets shall be stationary bull's-eye type. All moving targets are prohibited. b. There shall be provided a target carrier system or device for running the targets back and forth between the firing line and the bullet stop which will eliminate the necessity of anyone going in front of the firing line during the progress of firing for the purpose of changing targets. 6. FIRING LINE. At the firing line a bench, shelf or other separation, not less than 3 feet high and running the width of the range, shall be provided. The lower part of such bench, shelf or other separation shall be open to permit shooting under it in the kneeling, sitting, or prone position. No person, except the person in charge, shall be permitted in front of the firing line during the progress of firing. 7. SOUND QUIETING TREATMENT. Shooting premises, located adjacent to premises used in whole or in part for residence purposes, shall not be offensive by reason of the emission of noise to the outdoors. In such cases, where the noise of firing is conveyed to the outdoors, the walls and ceiling of the shooting premises or range shall be covered with sufficient sound absorbing material to eliminate the nuisance, or sound absorbing boxes, in which the muzzle of the gun is inserted before firing, shall be used.

Ask a question about Milwaukee law

Corpus searches the Milwaukee sections it holds and shows the ones that match, with their citations. Free, no sign-in.